Improved reproducibility for myocardial ASL: impact of physiological and acquisition parameters

Purpose To investigate and mitigate the influence of physiological and acquisition-related parameters on myocardial blood flow (MBF) measurements obtained with myocardial Arterial Spin Labeling (myoASL). Methods A Flow-sensitive Alternating Inversion Recovery (FAIR) myoASL sequence with bSSFP and sp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Božić-Iven, Maša (VerfasserIn) , Rapacchi, Stanislas (VerfasserIn) , Tao, Qian (VerfasserIn) , Pierce, Iain (VerfasserIn) , Thornton, George (VerfasserIn) , Nitsche, Christian (VerfasserIn) , Treibel, Thomas A. (VerfasserIn) , Schad, Lothar R. (VerfasserIn) , Weingärtner, Sebastian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: January 2024
In: Magnetic resonance in medicine
Year: 2024, Jahrgang: 91, Heft: 1, Pages: 118-132
ISSN:1522-2594
DOI:10.1002/mrm.29834
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1002/mrm.29834
Verlag, kostenfrei, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.29834
Volltext
Verfasserangaben:Maša Božić-Iven, Stanislas Rapacchi, Qian Tao, Iain Pierce, George Thornton, Christian Nitsche, Thomas A. Treibel, Lothar R. Schad, Sebastian Weingärtner

MARC

LEADER 00000caa a2200000 c 4500
001 1883184568
003 DE-627
005 20240703153037.0
007 cr uuu---uuuuu
008 240312s2024 xx |||||o 00| ||eng c
024 7 |a 10.1002/mrm.29834  |2 doi 
035 |a (DE-627)1883184568 
035 |a (DE-599)KXP1883184568 
035 |a (OCoLC)1443645467 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Božić-Iven, Maša  |d 1994-  |e VerfasserIn  |0 (DE-588)1269050389  |0 (DE-627)1817715232  |4 aut 
245 1 0 |a Improved reproducibility for myocardial ASL  |b impact of physiological and acquisition parameters  |c Maša Božić-Iven, Stanislas Rapacchi, Qian Tao, Iain Pierce, George Thornton, Christian Nitsche, Thomas A. Treibel, Lothar R. Schad, Sebastian Weingärtner 
264 1 |c January 2024 
300 |b Illustrationen 
300 |a 15 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online veröffentlicht: 5. September 2023 
500 |a Gesehen am 12.03.2024 
520 |a Purpose To investigate and mitigate the influence of physiological and acquisition-related parameters on myocardial blood flow (MBF) measurements obtained with myocardial Arterial Spin Labeling (myoASL). Methods A Flow-sensitive Alternating Inversion Recovery (FAIR) myoASL sequence with bSSFP and spoiled GRE (spGRE) readout is investigated for MBF quantification. Bloch-equation simulations and phantom experiments were performed to evaluate how variations in acquisition flip angle (FA), acquisition matrix size (AMS), heart rate (HR) and blood T1\ \mathrmT_1 \ relaxation time (T1,B\ \mathrmT_1,B \) affect quantification of myoASL-MBF. In vivo myoASL-images were acquired in nine healthy subjects. A corrected MBF quantification approach was proposed based on subject-specific T1,B\ \mathrmT_1,B \ values and, for spGRE imaging, subtracting an additional saturation-prepared baseline from the original baseline signal. Results Simulated and phantom experiments showed a strong dependence on AMS and FA (R2\ R^2 \>0.73), which was eliminated in simulations and alleviated in phantom experiments using the proposed saturation-baseline correction in spGRE. Only a very mild HR dependence (R2\ R^2 \>0.59) was observed which was reduced when calculating MBF with individual T1,B\ \mathrmT_1,B \. For corrected spGRE, in vivo mean global spGRE-MBF ranged from 0.54 to 2.59 mL/g/min and was in agreement with previously reported values. Compared to uncorrected spGRE, the intra-subject variability within a measurement (0.60 mL/g/min), between measurements (0.45 mL/g/min), as well as the inter-subject variability (1.29 mL/g/min) were improved by up to 40% and were comparable with conventional bSSFP. Conclusion Our results show that physiological and acquisition-related factors can lead to spurious changes in myoASL-MBF if not accounted for. Using individual T1,B\ \mathrmT_1,B \ and a saturation-baseline can reduce these variations in spGRE and improve reproducibility of FAIR-myoASL against acquisition parameters. 
650 4 |a cardiac arterial spin labeling 
650 4 |a cardiac magnetic resonance imaging 
650 4 |a flow-sensitive alternating inversion recovery 
650 4 |a myocardial blood flow 
700 1 |a Rapacchi, Stanislas  |e VerfasserIn  |4 aut 
700 1 |a Tao, Qian  |e VerfasserIn  |4 aut 
700 1 |a Pierce, Iain  |e VerfasserIn  |4 aut 
700 1 |a Thornton, George  |e VerfasserIn  |4 aut 
700 1 |a Nitsche, Christian  |e VerfasserIn  |4 aut 
700 1 |a Treibel, Thomas A.  |e VerfasserIn  |4 aut 
700 1 |a Schad, Lothar R.  |d 1956-  |e VerfasserIn  |0 (DE-588)1028817630  |0 (DE-627)731640241  |0 (DE-576)376271221  |4 aut 
700 1 |a Weingärtner, Sebastian  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in medicine  |d New York, NY [u.a.] : Wiley-Liss, 1984  |g 91(2024), 1 vom: Jan., Seite 118-132  |h Online-Ressource  |w (DE-627)303257040  |w (DE-600)1493786-4  |w (DE-576)096290455  |x 1522-2594  |7 nnas  |a Improved reproducibility for myocardial ASL impact of physiological and acquisition parameters 
773 1 8 |g volume:91  |g year:2024  |g number:1  |g month:01  |g pages:118-132  |g extent:15  |a Improved reproducibility for myocardial ASL impact of physiological and acquisition parameters 
856 4 0 |u https://doi.org/10.1002/mrm.29834  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.29834  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20240312 
993 |a Article 
994 |a 2024 
998 |g 1028817630  |a Schad, Lothar R.  |m 1028817630:Schad, Lothar R.  |d 60000  |d 65200  |e 60000PS1028817630  |e 65200PS1028817630  |k 0/60000/  |k 1/60000/65200/  |p 8 
998 |g 1269050389  |a Božić-Iven, Maša  |m 1269050389:Božić-Iven, Maša  |d 130000  |e 130000PB1269050389  |k 0/130000/  |p 1  |x j 
999 |a KXP-PPN1883184568  |e 4499559308 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"type":{"media":"Online-Ressource","bibl":"periodical"},"origin":[{"dateIssuedKey":"1984","publisherPlace":"New York, NY [u.a.]","dateIssuedDisp":"1984-","publisher":"Wiley-Liss"}],"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"part":{"issue":"1","volume":"91","text":"91(2024), 1 vom: Jan., Seite 118-132","pages":"118-132","year":"2024","extent":"15"},"note":["Gesehen am 28.02.08"],"disp":"Improved reproducibility for myocardial ASL impact of physiological and acquisition parametersMagnetic resonance in medicine","id":{"issn":["1522-2594"],"doi":["10.1002/(ISSN)1522-2594"],"eki":["303257040"],"zdb":["1493786-4"]},"title":[{"subtitle":"MRM ; an official journal of the International Society for Magnetic Resonance in Medicine","title_sort":"Magnetic resonance in medicine","title":"Magnetic resonance in medicine"}],"recId":"303257040","titleAlt":[{"title":"MRM"}],"pubHistory":["1.1984 -"]}],"person":[{"role":"aut","display":"Božić-Iven, Maša","given":"Maša","roleDisplay":"VerfasserIn","family":"Božić-Iven"},{"roleDisplay":"VerfasserIn","family":"Rapacchi","given":"Stanislas","display":"Rapacchi, Stanislas","role":"aut"},{"given":"Qian","role":"aut","display":"Tao, Qian","family":"Tao","roleDisplay":"VerfasserIn"},{"display":"Pierce, Iain","role":"aut","given":"Iain","family":"Pierce","roleDisplay":"VerfasserIn"},{"given":"George","display":"Thornton, George","role":"aut","family":"Thornton","roleDisplay":"VerfasserIn"},{"role":"aut","display":"Nitsche, Christian","given":"Christian","roleDisplay":"VerfasserIn","family":"Nitsche"},{"role":"aut","display":"Treibel, Thomas A.","given":"Thomas A.","family":"Treibel","roleDisplay":"VerfasserIn"},{"family":"Schad","roleDisplay":"VerfasserIn","given":"Lothar R.","display":"Schad, Lothar R.","role":"aut"},{"family":"Weingärtner","roleDisplay":"VerfasserIn","role":"aut","display":"Weingärtner, Sebastian","given":"Sebastian"}],"name":{"displayForm":["Maša Božić-Iven, Stanislas Rapacchi, Qian Tao, Iain Pierce, George Thornton, Christian Nitsche, Thomas A. Treibel, Lothar R. Schad, Sebastian Weingärtner"]},"physDesc":[{"extent":"15 S.","noteIll":"Illustrationen"}],"origin":[{"dateIssuedDisp":"January 2024","dateIssuedKey":"2024"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"note":["Online veröffentlicht: 5. September 2023","Gesehen am 12.03.2024"],"recId":"1883184568","id":{"doi":["10.1002/mrm.29834"],"eki":["1883184568"]},"title":[{"title_sort":"Improved reproducibility for myocardial ASL","title":"Improved reproducibility for myocardial ASL","subtitle":"impact of physiological and acquisition parameters"}]} 
SRT |a BOZICIVENMIMPROVEDRE2024