3-D quantification of the aortic arch morphology in 3-D CTA data for endovascular aortic repair
We introduce a new model-based approach for the segmentation and quantification of the aortic arch morphology in 3-D computed tomography angiography (CTA) data for thoracic endovascular aortic repair (TEVAR). The approach is based on a model-fitting scheme using a 3-D analytic intensity model for th...
Gespeichert in:
| Hauptverfasser: | , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
October 2010
|
| In: |
IEEE transactions on biomedical engineering
Year: 2010, Jahrgang: 57, Heft: 10, Pages: 2359-2368 |
| ISSN: | 1558-2531 |
| DOI: | 10.1109/TBME.2010.2053539 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1109/TBME.2010.2053539 Verlag, lizenzpflichtig, Volltext: https://ieeexplore.ieee.org/document/5491100 |
| Verfasserangaben: | Stefan Wörz, Hendrik von Tengg-Kobligk, Verena Henninger, Fabian Rengier, Hardy Schumacher, Dittmar Böckler, Hans-Ulrich Kauczor, and Karl Rohr |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1883929873 | ||
| 003 | DE-627 | ||
| 005 | 20240703155208.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 240320s2010 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1109/TBME.2010.2053539 |2 doi | |
| 035 | |a (DE-627)1883929873 | ||
| 035 | |a (DE-599)KXP1883929873 | ||
| 035 | |a (OCoLC)1443657588 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Wörz, Stefan |e VerfasserIn |0 (DE-588)173874207 |0 (DE-627)698775953 |0 (DE-576)134712765 |4 aut | |
| 245 | 1 | 0 | |a 3-D quantification of the aortic arch morphology in 3-D CTA data for endovascular aortic repair |c Stefan Wörz, Hendrik von Tengg-Kobligk, Verena Henninger, Fabian Rengier, Hardy Schumacher, Dittmar Böckler, Hans-Ulrich Kauczor, and Karl Rohr |
| 264 | 1 | |c October 2010 | |
| 300 | |b Illustrationen | ||
| 300 | |a 10 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Date of publication: 21 June 2010 | ||
| 500 | |a Gesehen am 20.03.2024 | ||
| 520 | |a We introduce a new model-based approach for the segmentation and quantification of the aortic arch morphology in 3-D computed tomography angiography (CTA) data for thoracic endovascular aortic repair (TEVAR). The approach is based on a model-fitting scheme using a 3-D analytic intensity model for thick vessels in conjunction with a two-step refinement procedure, and allows us to accurately quantify the morphology of the aortic arch. Based on the fitting results, we additionally compute the (local) 3-D vessel curvature and torsion as well as the relevant lengths not only along the 3-D centerline, but particularly also along the inner and outer contour. These measurements are important for preoperative planning in TEVAR applications. We have validated our approach based on 3-D synthetic as well as 3-D MR phantom images. Moreover, we have successfully applied our approach using 3-D CTA datasets of the human thorax and have compared the results with ground truth obtained by a radiologist. We have also performed a quantitative comparison with a commercial vascular analysis software. | ||
| 650 | 4 | |a 3-D analytic intensity model | |
| 650 | 4 | |a 3-D aortic arch segmentation | |
| 650 | 4 | |a 3-D computed tomography angiography (CTA) data | |
| 650 | 4 | |a Anatomy | |
| 650 | 4 | |a Bioinformatics | |
| 650 | 4 | |a Carotid arteries | |
| 650 | 4 | |a Curve fitting | |
| 650 | 4 | |a endovascular graft (EVG) | |
| 650 | 4 | |a Humans | |
| 650 | 4 | |a Imaging phantoms | |
| 650 | 4 | |a Morphology | |
| 650 | 4 | |a Permission | |
| 650 | 4 | |a Radiology | |
| 650 | 4 | |a Thorax | |
| 700 | 1 | |a Tengg-Kobligk, Hendrik von |d 1972- |e VerfasserIn |0 (DE-588)129455733 |0 (DE-627)397663188 |0 (DE-576)297668501 |4 aut | |
| 700 | 1 | |a Henninger, Verena Anna |d 1982- |e VerfasserIn |0 (DE-588)1034111973 |0 (DE-627)744077508 |0 (DE-576)381760340 |4 aut | |
| 700 | 1 | |a Rengier, Fabian |d 1986- |e VerfasserIn |0 (DE-588)139065865 |0 (DE-627)608103284 |0 (DE-576)309935873 |4 aut | |
| 700 | 1 | |a Schumacher, Hardy |e VerfasserIn |0 (DE-588)1076347967 |0 (DE-627)834742330 |0 (DE-576)171768019 |4 aut | |
| 700 | 1 | |a Böckler, Dittmar |d 1966- |e VerfasserIn |0 (DE-588)1032367881 |0 (DE-627)738382868 |0 (DE-576)173503969 |4 aut | |
| 700 | 1 | |a Kauczor, Hans-Ulrich |d 1962- |e VerfasserIn |0 (DE-588)139267123 |0 (DE-627)70327113X |0 (DE-576)310955327 |4 aut | |
| 700 | 1 | |a Rohr, Karl |e VerfasserIn |0 (DE-588)137474466 |0 (DE-627)695829440 |0 (DE-576)303788593 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |a Institute of Electrical and Electronics Engineers |t IEEE transactions on biomedical engineering |d New York, NY : IEEE, 1964 |g 57(2010), 10 vom: Okt., Seite 2359-2368 |h Online-Ressource |w (DE-627)320614050 |w (DE-600)2021742-0 |w (DE-576)094080682 |x 1558-2531 |7 nnas |
| 773 | 1 | 8 | |g volume:57 |g year:2010 |g number:10 |g month:10 |g pages:2359-2368 |g extent:10 |a 3-D quantification of the aortic arch morphology in 3-D CTA data for endovascular aortic repair |
| 856 | 4 | 0 | |u https://doi.org/10.1109/TBME.2010.2053539 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://ieeexplore.ieee.org/document/5491100 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20240320 | ||
| 993 | |a Article | ||
| 994 | |a 2010 | ||
| 998 | |g 137474466 |a Rohr, Karl |m 137474466:Rohr, Karl |d 160000 |d 160100 |e 160000PR137474466 |e 160100PR137474466 |k 0/160000/ |k 1/160000/160100/ |p 7 | ||
| 998 | |g 139267123 |a Kauczor, Hans-Ulrich |m 139267123:Kauczor, Hans-Ulrich |d 910000 |d 911400 |e 910000PK139267123 |e 911400PK139267123 |k 0/910000/ |k 1/910000/911400/ |p 6 | ||
| 998 | |g 1076347967 |a Schumacher, Hardy |m 1076347967:Schumacher, Hardy |d 50000 |e 50000PS1076347967 |k 0/50000/ |p 5 | ||
| 998 | |g 139065865 |a Rengier, Fabian |m 139065865:Rengier, Fabian |d 50000 |e 50000PR139065865 |k 0/50000/ |p 4 | ||
| 998 | |g 1034111973 |a Henninger, Verena Anna |m 1034111973:Henninger, Verena Anna |d 50000 |e 50000PH1034111973 |k 0/50000/ |p 3 | ||
| 998 | |g 129455733 |a Tengg-Kobligk, Hendrik von |m 129455733:Tengg-Kobligk, Hendrik von |d 50000 |e 50000PT129455733 |k 0/50000/ |p 2 | ||
| 998 | |g 173874207 |a Wörz, Stefan |m 173874207:Wörz, Stefan |d 160000 |d 160100 |e 160000PW173874207 |e 160100PW173874207 |k 0/160000/ |k 1/160000/160100/ |p 1 |x j | ||
| 999 | |a KXP-PPN1883929873 |e 4502226165 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"name":{"displayForm":["Stefan Wörz, Hendrik von Tengg-Kobligk, Verena Henninger, Fabian Rengier, Hardy Schumacher, Dittmar Böckler, Hans-Ulrich Kauczor, and Karl Rohr"]},"id":{"eki":["1883929873"],"doi":["10.1109/TBME.2010.2053539"]},"person":[{"display":"Wörz, Stefan","given":"Stefan","role":"aut","family":"Wörz"},{"family":"Tengg-Kobligk","given":"Hendrik von","role":"aut","display":"Tengg-Kobligk, Hendrik von"},{"display":"Henninger, Verena Anna","family":"Henninger","given":"Verena Anna","role":"aut"},{"family":"Rengier","role":"aut","given":"Fabian","display":"Rengier, Fabian"},{"display":"Schumacher, Hardy","role":"aut","given":"Hardy","family":"Schumacher"},{"display":"Böckler, Dittmar","role":"aut","given":"Dittmar","family":"Böckler"},{"display":"Kauczor, Hans-Ulrich","family":"Kauczor","role":"aut","given":"Hans-Ulrich"},{"family":"Rohr","role":"aut","given":"Karl","display":"Rohr, Karl"}],"relHost":[{"name":{"displayForm":["Institute of Electrical and Electronics Engineers"]},"pubHistory":["11.1964 -"],"titleAlt":[{"title":"Transactions on biomedical engineering"}],"corporate":[{"display":"Institute of Electrical and Electronics Engineers","role":"aut"}],"id":{"zdb":["2021742-0"],"issn":["1558-2531"],"eki":["320614050"]},"part":{"pages":"2359-2368","issue":"10","text":"57(2010), 10 vom: Okt., Seite 2359-2368","extent":"10","year":"2010","volume":"57"},"recId":"320614050","physDesc":[{"extent":"Online-Ressource"}],"disp":"Institute of Electrical and Electronics EngineersIEEE transactions on biomedical engineering","origin":[{"dateIssuedDisp":"1964-","dateIssuedKey":"1964","publisherPlace":"New York, NY","publisher":"IEEE"}],"title":[{"title":"IEEE transactions on biomedical engineering","title_sort":"IEEE transactions on biomedical engineering","subtitle":"a publication of the IEEE Engineering in Medicine and Biology Society"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"]}],"origin":[{"dateIssuedKey":"2010","dateIssuedDisp":"October 2010"}],"note":["Date of publication: 21 June 2010","Gesehen am 20.03.2024"],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title_sort":"3-D quantification of the aortic arch morphology in 3-D CTA data for endovascular aortic repair","title":"3-D quantification of the aortic arch morphology in 3-D CTA data for endovascular aortic repair"}],"physDesc":[{"noteIll":"Illustrationen","extent":"10 S."}],"recId":"1883929873"} | ||
| SRT | |a WOERZSTEFA3DQUANTIFI2010 | ||