Photon-Counting Computed Tomography (PC-CT) of the spine: impact on diagnostic confidence and radiation dose
Computed tomography (CT) is employed to evaluate surgical outcome after spinal interventions. Here, we investigate the potential of multispectral photon-counting computed tomography (PC-CT) on image quality, diagnostic confidence, and radiation dose compared to an energy-integrating CT (EID-CT).
Gespeichert in:
| Hauptverfasser: | , , , , , , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
August 2023
|
| In: |
European radiology
Year: 2023, Jahrgang: 33, Heft: 8, Pages: 5578-5586 |
| ISSN: | 1432-1084 |
| DOI: | 10.1007/s00330-023-09511-5 |
| Online-Zugang: | Verlag, kostenfrei, Volltext: https://doi.org/10.1007/s00330-023-09511-5 Verlag, kostenfrei, Volltext: https://link.springer.com/article/10.1007/s00330-023-09511-5 |
| Verfasserangaben: | Alexander Rau, Jakob Straehle, Thomas Stein, Thierno Diallo, Stephan Rau, Sebastian Faby, Konstantin Nikolaou, Stefan O. Schoenberg, Daniel Overhoff, Jürgen Beck, Horst Urbach, Jan-Helge Klingler, Fabian Bamberg, Jakob Weiss |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1885011636 | ||
| 003 | DE-627 | ||
| 005 | 20250116215955.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 240404s2023 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s00330-023-09511-5 |2 doi | |
| 035 | |a (DE-627)1885011636 | ||
| 035 | |a (DE-599)KXP1885011636 | ||
| 035 | |a (OCoLC)1443668220 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Rau, Alexander |e VerfasserIn |0 (DE-588)1183422377 |0 (DE-627)1663190267 |4 aut | |
| 245 | 1 | 0 | |a Photon-Counting Computed Tomography (PC-CT) of the spine |b impact on diagnostic confidence and radiation dose |c Alexander Rau, Jakob Straehle, Thomas Stein, Thierno Diallo, Stephan Rau, Sebastian Faby, Konstantin Nikolaou, Stefan O. Schoenberg, Daniel Overhoff, Jürgen Beck, Horst Urbach, Jan-Helge Klingler, Fabian Bamberg, Jakob Weiss |
| 264 | 1 | |c August 2023 | |
| 300 | |b Illustrationen | ||
| 300 | |a 9 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Online veröffentlicht: 9. März 2023 | ||
| 500 | |a Gesehen am 04.04.2024 | ||
| 520 | |a Computed tomography (CT) is employed to evaluate surgical outcome after spinal interventions. Here, we investigate the potential of multispectral photon-counting computed tomography (PC-CT) on image quality, diagnostic confidence, and radiation dose compared to an energy-integrating CT (EID-CT). | ||
| 650 | 4 | |a Artifacts | |
| 650 | 4 | |a Bone screws | |
| 650 | 4 | |a Radiation dosage | |
| 650 | 4 | |a Radiology | |
| 650 | 4 | |a Tomography, X-ray computed | |
| 700 | 1 | |8 1\p |a Strähle, Jakob |d 1988- |e VerfasserIn |0 (DE-588)113663049X |0 (DE-627)893334308 |0 (DE-576)490717020 |4 aut | |
| 700 | 1 | |a Stein, Thomas |e VerfasserIn |4 aut | |
| 700 | 1 | |a Diallo, Thierno |e VerfasserIn |4 aut | |
| 700 | 1 | |8 2\p |a Rau, Stephan Georg |d 1983- |e VerfasserIn |0 (DE-588)1048440125 |0 (DE-627)780418921 |0 (DE-576)402259696 |4 aut | |
| 700 | 1 | |a Faby, Sebastian |e VerfasserIn |4 aut | |
| 700 | 1 | |8 3\p |a Nikolaou, Konstantin |d 1973- |e VerfasserIn |0 (DE-588)12262436X |0 (DE-627)705975630 |0 (DE-576)293353131 |4 aut | |
| 700 | 1 | |a Schönberg, Stefan |d 1969- |e VerfasserIn |0 (DE-588)131557912 |0 (DE-627)510700624 |0 (DE-576)298584891 |4 aut | |
| 700 | 1 | |a Overhoff, Daniel |d 1984- |e VerfasserIn |0 (DE-588)1098192257 |0 (DE-627)85747944X |0 (DE-576)469013397 |4 aut | |
| 700 | 1 | |8 4\p |a Beck, Jürgen |d 1970- |e VerfasserIn |0 (DE-588)129082007 |0 (DE-627)388712767 |0 (DE-576)297484419 |4 aut | |
| 700 | 1 | |8 5\p |a Urbach, Horst |d 1962- |e VerfasserIn |0 (DE-588)123463084 |0 (DE-627)082569878 |0 (DE-576)293719357 |4 aut | |
| 700 | 1 | |8 6\p |a Klingler, Jan-Helge |d 1978- |e VerfasserIn |0 (DE-588)132680491 |0 (DE-627)525179453 |0 (DE-576)299338509 |4 aut | |
| 700 | 1 | |8 7\p |a Bamberg, Fabian |e VerfasserIn |0 (DE-588)1014292778 |0 (DE-627)666272611 |0 (DE-576)348575343 |4 aut | |
| 700 | 1 | |a Weiss, Jakob |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t European radiology |d Berlin : Springer, 1991 |g 33(2023), 8 vom: Aug., Seite 5578-5586 |h Online-Ressource |w (DE-627)268757526 |w (DE-600)1472718-3 |w (DE-576)103868070 |x 1432-1084 |7 nnas |a Photon-Counting Computed Tomography (PC-CT) of the spine impact on diagnostic confidence and radiation dose |
| 773 | 1 | 8 | |g volume:33 |g year:2023 |g number:8 |g month:08 |g pages:5578-5586 |g extent:9 |a Photon-Counting Computed Tomography (PC-CT) of the spine impact on diagnostic confidence and radiation dose |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00330-023-09511-5 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://link.springer.com/article/10.1007/s00330-023-09511-5 |x Verlag |z kostenfrei |3 Volltext |
| 883 | |8 1\p |a cgwrk |d 20241001 |q DE-101 |u https://d-nb.info/provenance/plan#cgwrk | ||
| 883 | |8 2\p |a cgwrk |d 20241001 |q DE-101 |u https://d-nb.info/provenance/plan#cgwrk | ||
| 883 | |8 3\p |a cgwrk |d 20241001 |q DE-101 |u https://d-nb.info/provenance/plan#cgwrk | ||
| 883 | |8 4\p |a cgwrk |d 20241001 |q DE-101 |u https://d-nb.info/provenance/plan#cgwrk | ||
| 883 | |8 5\p |a cgwrk |d 20241001 |q DE-101 |u https://d-nb.info/provenance/plan#cgwrk | ||
| 883 | |8 6\p |a cgwrk |d 20241001 |q DE-101 |u https://d-nb.info/provenance/plan#cgwrk | ||
| 883 | |8 7\p |a cgwrk |d 20241001 |q DE-101 |u https://d-nb.info/provenance/plan#cgwrk | ||
| 951 | |a AR | ||
| 992 | |a 20240404 | ||
| 993 | |a Article | ||
| 994 | |a 2023 | ||
| 998 | |g 1098192257 |a Overhoff, Daniel |m 1098192257:Overhoff, Daniel |d 60000 |e 60000PO1098192257 |k 0/60000/ |p 9 | ||
| 998 | |g 131557912 |a Schönberg, Stefan |m 131557912:Schönberg, Stefan |d 60000 |d 62900 |e 60000PS131557912 |e 62900PS131557912 |k 0/60000/ |k 1/60000/62900/ |p 8 | ||
| 999 | |a KXP-PPN1885011636 |e 450724059X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"recId":"1885011636","language":["eng"],"id":{"doi":["10.1007/s00330-023-09511-5"],"eki":["1885011636"]},"physDesc":[{"noteIll":"Illustrationen","extent":"9 S."}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Online veröffentlicht: 9. März 2023","Gesehen am 04.04.2024"],"title":[{"subtitle":"impact on diagnostic confidence and radiation dose","title":"Photon-Counting Computed Tomography (PC-CT) of the spine","title_sort":"Photon-Counting Computed Tomography (PC-CT) of the spine"}],"person":[{"display":"Rau, Alexander","family":"Rau","roleDisplay":"VerfasserIn","role":"aut","given":"Alexander"},{"role":"aut","given":"Jakob","roleDisplay":"VerfasserIn","family":"Strähle","display":"Strähle, Jakob"},{"role":"aut","given":"Thomas","family":"Stein","display":"Stein, Thomas","roleDisplay":"VerfasserIn"},{"role":"aut","given":"Thierno","roleDisplay":"VerfasserIn","display":"Diallo, Thierno","family":"Diallo"},{"given":"Stephan Georg","role":"aut","roleDisplay":"VerfasserIn","display":"Rau, Stephan Georg","family":"Rau"},{"family":"Faby","display":"Faby, Sebastian","roleDisplay":"VerfasserIn","role":"aut","given":"Sebastian"},{"role":"aut","given":"Konstantin","family":"Nikolaou","display":"Nikolaou, Konstantin","roleDisplay":"VerfasserIn"},{"given":"Stefan","role":"aut","roleDisplay":"VerfasserIn","family":"Schönberg","display":"Schönberg, Stefan"},{"roleDisplay":"VerfasserIn","display":"Overhoff, Daniel","family":"Overhoff","given":"Daniel","role":"aut"},{"given":"Jürgen","role":"aut","display":"Beck, Jürgen","family":"Beck","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","family":"Urbach","display":"Urbach, Horst","given":"Horst","role":"aut"},{"given":"Jan-Helge","role":"aut","roleDisplay":"VerfasserIn","display":"Klingler, Jan-Helge","family":"Klingler"},{"role":"aut","given":"Fabian","roleDisplay":"VerfasserIn","family":"Bamberg","display":"Bamberg, Fabian"},{"given":"Jakob","role":"aut","display":"Weiss, Jakob","family":"Weiss","roleDisplay":"VerfasserIn"}],"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"August 2023"}],"name":{"displayForm":["Alexander Rau, Jakob Straehle, Thomas Stein, Thierno Diallo, Stephan Rau, Sebastian Faby, Konstantin Nikolaou, Stefan O. Schoenberg, Daniel Overhoff, Jürgen Beck, Horst Urbach, Jan-Helge Klingler, Fabian Bamberg, Jakob Weiss"]},"relHost":[{"part":{"text":"33(2023), 8 vom: Aug., Seite 5578-5586","issue":"8","extent":"9","year":"2023","pages":"5578-5586","volume":"33"},"corporate":[{"role":"isb","display":"European Association of Radiology","roleDisplay":"Herausgebendes Organ"}],"origin":[{"publisherPlace":"Berlin ; Heidelberg","dateIssuedKey":"1991","publisher":"Springer","dateIssuedDisp":"1991-"}],"pubHistory":["1.1991 -"],"disp":"Photon-Counting Computed Tomography (PC-CT) of the spine impact on diagnostic confidence and radiation doseEuropean radiology","note":["Gesehen am 06.02.2018","Ungezählte Beil.: Supplement"],"title":[{"title_sort":"European radiology","title":"European radiology","subtitle":"official organ of the European Association of Radiology"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"id":{"zdb":["1472718-3"],"issn":["1432-1084","1613-3757"],"eki":["268757526"]},"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"recId":"268757526","titleAlt":[{"title":"European radiology / Supplement"},{"title":"European radiology supplements"}]}]} | ||
| SRT | |a RAUALEXANDPHOTONCOUN2023 | ||