Patients’ plasma activity of heparin, low-molecular-weight heparin or no anticoagulants on urine based DOAC test strips

DOAC Dipstick determines specifically the presence and absence of direct oral anticoagulants (DOACs) from patients’ urine samples and handmade test strips performed as well as the commercial version. To compare plasma activity (chromogenic substrate assays) from plasma samples with results from urin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Harenberg, Job (VerfasserIn) , Hetjens, Svetlana (VerfasserIn) , Weiß, Christel (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: January-December 2022
In: Clinical and applied thrombosis, hemostasis
Year: 2022, Jahrgang: 28, Pages: 1-4
ISSN:1938-2723
DOI:10.1177/10760296221083667
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1177/10760296221083667
Verlag, kostenfrei, Volltext: https://journals.sagepub.com/doi/10.1177/10760296221083667
Volltext
Verfasserangaben:Job Harenberg, Svetlana Hetjens, and Christel Weiss

MARC

LEADER 00000caa a2200000 c 4500
001 1886542724
003 DE-627
005 20240703170536.0
007 cr uuu---uuuuu
008 240423s2022 xx |||||o 00| ||eng c
024 7 |a 10.1177/10760296221083667  |2 doi 
035 |a (DE-627)1886542724 
035 |a (DE-599)KXP1886542724 
035 |a (OCoLC)1443669126 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Harenberg, Job  |d 1950-  |e VerfasserIn  |0 (DE-588)108825507  |0 (DE-627)655891498  |0 (DE-576)339563745  |4 aut 
245 1 0 |a Patients’ plasma activity of heparin, low-molecular-weight heparin or no anticoagulants on urine based DOAC test strips  |c Job Harenberg, Svetlana Hetjens, and Christel Weiss 
264 1 |c January-December 2022 
300 |a 4 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Erstmals online veröffentlicht: 11. März 2022 
500 |a Gesehen am 23.04.2024 
520 |a DOAC Dipstick determines specifically the presence and absence of direct oral anticoagulants (DOACs) from patients’ urine samples and handmade test strips performed as well as the commercial version. To compare plasma activity (chromogenic substrate assays) from plasma samples with results from urine samples (DOAC test strips) of patients treated with heparin, low-molecular weight heparin (LMWH) and without anticoagulation. Plasma anti-factor Xa (aXa) activity was determined by Coamatic chromogenic substrate assay and compared to the presence of anticoagulants in urine by DOAC test strips. Patients were treated for least 5 days and samples were taken 4 hrs after administration in comparison to no treatment with an anticoagulant (n = 42). A total of 100 patients were included treated with heparin (n = 29), LMWH nadroparin (n = 29) or no anticoagulants (n = 42). Plasma aXa levels of patients treated with heparin (2 × 7.500 IU daily subcutaneously, 12 male, age 67.4 ± 11.5 years) were 0,18 IU/ml ± 0,15 IU/ml (mean, standard deviation), with LMWH (1 × 3000 IU daily subcutaneously, 15 male, age 64.2 ± 14.1 years) 0,17 IU/ml ± 0,16 IU/l, and with no anticoagulants (28 male, age 64.2 ± 15.6 years) 0,02 IU/ml ± 0.01 IU/ml. All factor Xa and thrombin inhibitor pad results of test strips were negative. We conclude that DOAC Dipstick has a high probability of not detecting heparin and LMWH in patients on treatment as well as in urine samples of patients not treated with an anticoagulant. 
700 1 |a Hetjens, Svetlana  |d 1983-  |e VerfasserIn  |0 (DE-588)1031801979  |0 (DE-627)737600284  |0 (DE-576)379534223  |4 aut 
700 1 |a Weiß, Christel  |d 1958-  |e VerfasserIn  |0 (DE-588)123287707  |0 (DE-627)082463417  |0 (DE-576)168356104  |4 aut 
773 0 8 |i Enthalten in  |t Clinical and applied thrombosis, hemostasis  |d Thousand Oaks, Calif. : Sage, 1995  |g 28(2022), Seite 1-4  |h Online-Ressource  |w (DE-627)510464181  |w (DE-600)2230591-9  |w (DE-576)276272900  |x 1938-2723  |7 nnas  |a Patients’ plasma activity of heparin, low-molecular-weight heparin or no anticoagulants on urine based DOAC test strips 
773 1 8 |g volume:28  |g year:2022  |g month:1-  |g pages:1-4  |g extent:4  |a Patients’ plasma activity of heparin, low-molecular-weight heparin or no anticoagulants on urine based DOAC test strips 
856 4 0 |u https://doi.org/10.1177/10760296221083667  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://journals.sagepub.com/doi/10.1177/10760296221083667  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20240423 
993 |a Article 
994 |a 2022 
998 |g 123287707  |a Weiß, Christel  |m 123287707:Weiß, Christel  |d 60000  |d 60200  |d 60250  |d 60000  |e 60000PW123287707  |e 60200PW123287707  |e 60250PW123287707  |e 60000PW123287707  |k 0/60000/  |k 1/60000/60200/  |k 2/60000/60200/60250/  |k 0/60000/  |p 3  |y j 
998 |g 1031801979  |a Hetjens, Svetlana  |m 1031801979:Hetjens, Svetlana  |d 60000  |d 60200  |d 60250  |e 60000PH1031801979  |e 60200PH1031801979  |e 60250PH1031801979  |k 0/60000/  |k 1/60000/60200/  |k 2/60000/60200/60250/  |p 2 
998 |g 108825507  |a Harenberg, Job  |m 108825507:Harenberg, Job  |d 60000  |e 60000PH108825507  |k 0/60000/  |p 1  |x j 
999 |a KXP-PPN1886542724  |e 4514900419 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["510464181"],"zdb":["2230591-9"],"issn":["1938-2723"]},"part":{"extent":"4","year":"2022","pages":"1-4","volume":"28","text":"28(2022), Seite 1-4"},"note":["Gesehen am 25.05.2020","Fortsetzung der Druck-Ausgabe"],"origin":[{"dateIssuedDisp":"1995-","publisher":"Sage","publisherPlace":"Thousand Oaks, Calif.","dateIssuedKey":"1995"}],"title":[{"title":"Clinical and applied thrombosis, hemostasis","title_sort":"Clinical and applied thrombosis, hemostasis"}],"pubHistory":["1.1995 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"510464181","disp":"Patients’ plasma activity of heparin, low-molecular-weight heparin or no anticoagulants on urine based DOAC test stripsClinical and applied thrombosis, hemostasis","language":["eng"]}],"note":["Erstmals online veröffentlicht: 11. März 2022","Gesehen am 23.04.2024"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"eki":["1886542724"],"doi":["10.1177/10760296221083667"]},"physDesc":[{"extent":"4 S."}],"language":["eng"],"title":[{"title":"Patients’ plasma activity of heparin, low-molecular-weight heparin or no anticoagulants on urine based DOAC test strips","title_sort":"Patients’ plasma activity of heparin, low-molecular-weight heparin or no anticoagulants on urine based DOAC test strips"}],"recId":"1886542724","name":{"displayForm":["Job Harenberg, Svetlana Hetjens, and Christel Weiss"]},"origin":[{"dateIssuedKey":"2022","dateIssuedDisp":"January-December 2022"}],"person":[{"family":"Harenberg","display":"Harenberg, Job","given":"Job","role":"aut"},{"family":"Hetjens","given":"Svetlana","display":"Hetjens, Svetlana","role":"aut"},{"family":"Weiß","given":"Christel","display":"Weiß, Christel","role":"aut"}]} 
SRT |a HARENBERGJPATIENTSPL2022