First experience with the new extracorporeal membrane oxygenation system Colibri

Introduction: Extracorporeal membrane oxygenation (ECMO) is increasingly used for circulatory or pulmonary support not only in-hospital but also out-of-hospital. Small dimensions and a lightweight design are important, especially for out-of-hospital use but also for intra-hospital transportation of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Saemann, Lars (VerfasserIn) , Stiller, Markus (VerfasserIn) , Willsch, Jan (VerfasserIn) , Schultze, Thomas (VerfasserIn) , Matin, Meradjoddin (VerfasserIn) , Veres, Gábor (VerfasserIn) , Szabó, Gábor (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: January 2024
In: Artificial organs
Year: 2024, Jahrgang: 48, Heft: 1, Pages: 103-109
ISSN:1525-1594
DOI:10.1111/aor.14671
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1111/aor.14671
Verlag, kostenfrei, Volltext: https://onlinelibrary.wiley.com/doi/10.1111/aor.14671
Volltext
Verfasserangaben:Lars Saemann, Markus Stiller, Jan Willsch, Thomas Schultze, Meradjoddin Matin, Gabor Veres, Gabor Szabo

MARC

LEADER 00000caa a2200000 c 4500
001 1887435433
003 DE-627
005 20240703172254.0
007 cr uuu---uuuuu
008 240430s2024 xx |||||o 00| ||eng c
024 7 |a 10.1111/aor.14671  |2 doi 
035 |a (DE-627)1887435433 
035 |a (DE-599)KXP1887435433 
035 |a (OCoLC)1443669470 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Saemann, Lars  |d 1994-  |e VerfasserIn  |0 (DE-588)1203655118  |0 (DE-627)1688668497  |4 aut 
245 1 0 |a First experience with the new extracorporeal membrane oxygenation system Colibri  |c Lars Saemann, Markus Stiller, Jan Willsch, Thomas Schultze, Meradjoddin Matin, Gabor Veres, Gabor Szabo 
264 1 |c January 2024 
300 |b Illustrationen 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 30.04.2024 
520 |a Introduction: Extracorporeal membrane oxygenation (ECMO) is increasingly used for circulatory or pulmonary support not only in-hospital but also out-of-hospital. Small dimensions and a lightweight design are important, especially for out-of-hospital use but also for intra-hospital transportation of patients who require ECMO support. We share our first experience with the new Colibri ECMO system. Patients and Methods: From December 2022 to January 2023, we used the new Colibri extracorporeal circulation (ECC) system in six patients with cardiac or pulmonary failure. Results: The Colibri system was used in-hospital in six patients with post-cardiac surgery low output syndrome, respiratory failure due to influenza or acute respiratory distress syndrome, cardiogenic shock, pulmonary embolism, and failed weaning from cardiopulmonary bypass. The system was implanted in venovenous (VV) and venoarterial (VA) fashion in 3 patients, respectively. In one patient, the configuration was switched from VA to VV after cardiac recovery. One patient received left-ventricular unloading using the IMPELLA((R))5.5. ECMO run time was 1 to 13 days. We did not notice any ECC system-associated complications. No ECMO system changes were required. Conclusion: Our case series concludes that the new Colibri system is safe and effective for in-hospital ECMO indications. The small dimensions and lightweight design are very beneficial for the transportation of patients. It might be especially helpful for out-of-hospital situations. 
650 4 |a CENTRIMAG 
650 4 |a extracorporeal cardiopulmonary resuscitation 
650 4 |a extracorporeal life support 
650 4 |a extracorporeal membrane oxygenation 
700 1 |a Stiller, Markus  |d 1985-  |e VerfasserIn  |0 (DE-588)1121821758  |0 (DE-627)874964482  |0 (DE-576)480963037  |4 aut 
700 1 |a Willsch, Jan  |e VerfasserIn  |4 aut 
700 1 |a Schultze, Thomas  |e VerfasserIn  |4 aut 
700 1 |a Matin, Meradjoddin  |d 1961-  |e VerfasserIn  |0 (DE-588)133106705  |0 (DE-627)534950795  |0 (DE-576)265431085  |4 aut 
700 1 |a Veres, Gábor  |e VerfasserIn  |0 (DE-588)1080537139  |0 (DE-627)844782319  |0 (DE-576)453604927  |4 aut 
700 1 |a Szabó, Gábor  |d 1969-  |e VerfasserIn  |0 (DE-588)1022955152  |0 (DE-627)717338681  |0 (DE-576)366215485  |4 aut 
773 0 8 |i Enthalten in  |t Artificial organs  |d Oxford [u.a.] : Wiley-Blackwell, 1977  |g 48(2024), 1 vom: Jan., Seite 103-109  |h Online-Ressource  |w (DE-627)320431606  |w (DE-600)2003825-2  |w (DE-576)091140196  |x 1525-1594  |7 nnas  |a First experience with the new extracorporeal membrane oxygenation system Colibri 
773 1 8 |g volume:48  |g year:2024  |g number:1  |g month:01  |g pages:103-109  |g extent:7  |a First experience with the new extracorporeal membrane oxygenation system Colibri 
856 4 0 |u https://doi.org/10.1111/aor.14671  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/10.1111/aor.14671  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20240430 
993 |a Article 
994 |a 2023 
998 |g 1022955152  |a Szabó, Gábor  |m 1022955152:Szabó, Gábor  |d 910000  |d 910200  |d 50000  |e 910000PS1022955152  |e 910200PS1022955152  |e 50000PS1022955152  |k 0/910000/  |k 1/910000/910200/  |k 0/50000/  |p 6  |y j 
998 |g 1080537139  |a Veres, Gábor  |m 1080537139:Veres, Gábor  |d 50000  |e 50000PV1080537139  |k 0/50000/  |p 5 
998 |g 1203655118  |a Saemann, Lars  |m 1203655118:Saemann, Lars  |p 1  |x j 
999 |a KXP-PPN1887435433  |e 4519399122 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"7 S.","noteIll":"Illustrationen"}],"recId":"1887435433","language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 30.04.2024"],"title":[{"title":"First experience with the new extracorporeal membrane oxygenation system Colibri","title_sort":"First experience with the new extracorporeal membrane oxygenation system Colibri"}],"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"January 2024"}],"relHost":[{"origin":[{"dateIssuedKey":"1977","publisherPlace":"Oxford [u.a.] ; Malden, Mass. ; Oxford [u.a.]","dateIssuedDisp":"1977-","publisher":"Wiley-Blackwell ; Blackwell Science ; Blackwell"}],"title":[{"subtitle":"official journal of the International Federation for Artificial Organs and the International Faculty for Artificial Organs","title":"Artificial organs","title_sort":"Artificial organs"}],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 03.02.04"],"recId":"320431606","physDesc":[{"extent":"Online-Ressource"}],"disp":"First experience with the new extracorporeal membrane oxygenation system ColibriArtificial organs","pubHistory":["1.1977 -"],"corporate":[{"role":"isb","display":"International Society for Artificial Organs"}],"id":{"doi":["10.1111/(ISSN)1525-1594"],"zdb":["2003825-2"],"issn":["1525-1594"],"eki":["320431606"]},"part":{"pages":"103-109","extent":"7","text":"48(2024), 1 vom: Jan., Seite 103-109","issue":"1","year":"2024","volume":"48"}}],"person":[{"family":"Saemann","given":"Lars","role":"aut","display":"Saemann, Lars"},{"family":"Stiller","role":"aut","given":"Markus","display":"Stiller, Markus"},{"family":"Willsch","given":"Jan","role":"aut","display":"Willsch, Jan"},{"display":"Schultze, Thomas","given":"Thomas","role":"aut","family":"Schultze"},{"given":"Meradjoddin","role":"aut","family":"Matin","display":"Matin, Meradjoddin"},{"display":"Veres, Gábor","family":"Veres","given":"Gábor","role":"aut"},{"family":"Szabó","given":"Gábor","role":"aut","display":"Szabó, Gábor"}],"id":{"doi":["10.1111/aor.14671"],"eki":["1887435433"]},"name":{"displayForm":["Lars Saemann, Markus Stiller, Jan Willsch, Thomas Schultze, Meradjoddin Matin, Gabor Veres, Gabor Szabo"]}} 
SRT |a SAEMANNLARFIRSTEXPER2024