Continuous versus intermittent cardiac output measurement in cardiac surgical patients undergoing hypothermic cardiopulmonary bypass

Objective: - Continuous thermodilution cardiac output (CCO) measurement was clinically evaluated in patients who underwent coronary revascularization using hypothermic low-flow, low-pressure cardiopulmonary bypass (CPB). - Design: - Prospective study. - Setting: - University hospital setting. - Part...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Böttiger, Bernd W. (VerfasserIn) , Rauch, Helmut (VerfasserIn) , Böhrer, Hubert (VerfasserIn) , Motsch, Johann (VerfasserIn) , Soder, Michael (VerfasserIn) , Fleischer, Franz (VerfasserIn) , Martin, Eike (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: August 1995
In: Journal of cardiothoracic and vascular anesthesia
Year: 1995, Jahrgang: 9, Heft: 4, Pages: 405-411
ISSN:1532-8422
DOI:10.1016/S1053-0770(05)80095-3
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/S1053-0770(05)80095-3
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1053077005800953
Volltext
Verfasserangaben:Bernd W. Böttiger, Helmut Rauch, Hubert Böhrer, Johann Motsch, Michael Soder, Franz Fleischer, Eike Martin

MARC

LEADER 00000caa a2200000 c 4500
001 1888008628
003 DE-627
005 20240703173821.0
007 cr uuu---uuuuu
008 240507s1995 xx |||||o 00| ||eng c
024 7 |a 10.1016/S1053-0770(05)80095-3  |2 doi 
035 |a (DE-627)1888008628 
035 |a (DE-599)KXP1888008628 
035 |a (OCoLC)1443675625 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Böttiger, Bernd W.  |e VerfasserIn  |0 (DE-588)1103463691  |0 (DE-627)861085744  |0 (DE-576)470582464  |4 aut 
245 1 0 |a Continuous versus intermittent cardiac output measurement in cardiac surgical patients undergoing hypothermic cardiopulmonary bypass  |c Bernd W. Böttiger, Helmut Rauch, Hubert Böhrer, Johann Motsch, Michael Soder, Franz Fleischer, Eike Martin 
264 1 |c August 1995 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Elektronische Reproduktion der Druck-Ausgabe 25. August 2005 
500 |a Gesehen am 07.05.2024 
520 |a Objective: - Continuous thermodilution cardiac output (CCO) measurement was clinically evaluated in patients who underwent coronary revascularization using hypothermic low-flow, low-pressure cardiopulmonary bypass (CPB). - Design: - Prospective study. - Setting: - University hospital setting. - Participants: - 30 cardiac surgical patients. - Interventions: - CCO was correlated to standard bolus thermodilution cardiac output (ICO) obtained at end-expiration. - Measurements and Main Results: - Measurements were taken at selected time points (n = 18) before anesthesia induction, before CPB, and 5 minutes to 12 hours after CPB. A total of 540 data pairs were thus obtained. ICO ranged from 1.9 to 9.9 L/min, CCO from 1.5 to 9.9 L/min. Correlation between ICO and CCO was highly significant (r = 0.872; p < 0.01), accompanied by an excellent accuracy (bias −0.0213 L) and precision (0.59 L) before CPB and more than 45 minutes after CPB. However, during the first 45 minutes after CPB, there was no correlation (r = 0.273) between ICO and CCO, and ICO tended to be relatively high, whereas CCO measurements showed relatively low values. During the first 45 minutes after hypothermic CPB, but not during the ensuing time period, central blood temperature decreased, which may be interpreted as a lack of thermal equilibration between central and peripheral compartments. It is hypothesized that thermal instability in combination with increased respiratory variations in pulmonary artery blood temperature caused inhomogenous rewarming of different body sites and might be the main reason for the lack of correlation between ICO and CCO. - Conclusions: - Despite an excellent correlation, accuracy, and precision between CCO and ICO before CPB and more than 45 minutes after hypothermic CPB, a lack of correlation in the early phase after CPB has been found. Further investigation is needed to elucidate the underlying cause of these findings and to clarify whether ICO or CCO or both fail to represent the real cardiac output up to 45 minutes after weaning from hypothermic CPB. 
650 4 |a cardiac surgery 
650 4 |a continuous measurement 
650 4 |a hypothermic extracorporeal circulation 
650 4 |a thermodilution cardiac output 
700 1 |a Rauch, Helmut  |e VerfasserIn  |0 (DE-588)1059446510  |0 (DE-627)798468017  |0 (DE-576)415532582  |4 aut 
700 1 |a Böhrer, Hubert  |e VerfasserIn  |0 (DE-588)1074896521  |0 (DE-627)83266085X  |0 (DE-576)443103488  |4 aut 
700 1 |a Motsch, Johann  |d 1952-  |e VerfasserIn  |0 (DE-588)1059446626  |0 (DE-627)798468319  |0 (DE-576)415532876  |4 aut 
700 1 |a Soder, Michael  |d 1964-  |e VerfasserIn  |0 (DE-588)123544904  |0 (DE-627)706340647  |0 (DE-576)293759618  |4 aut 
700 1 |a Fleischer, Franz  |e VerfasserIn  |0 (DE-588)1071847945  |0 (DE-627)826472389  |0 (DE-576)433364467  |4 aut 
700 1 |a Martin, Eike  |d 1944-  |e VerfasserIn  |0 (DE-588)172250161  |0 (DE-627)697161390  |0 (DE-576)13311869X  |4 aut 
773 0 8 |i Enthalten in  |t Journal of cardiothoracic and vascular anesthesia  |d Philadelphia, Pa. : Saunders, 1991  |g 9(1995), 4, Seite 405-411  |h Online-Ressource  |w (DE-627)327643803  |w (DE-600)2043630-0  |w (DE-576)094145172  |x 1532-8422  |7 nnas  |a Continuous versus intermittent cardiac output measurement in cardiac surgical patients undergoing hypothermic cardiopulmonary bypass 
773 1 8 |g volume:9  |g year:1995  |g number:4  |g pages:405-411  |g extent:7  |a Continuous versus intermittent cardiac output measurement in cardiac surgical patients undergoing hypothermic cardiopulmonary bypass 
856 4 0 |u https://doi.org/10.1016/S1053-0770(05)80095-3  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1053077005800953  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20240507 
993 |a Article 
994 |a 1995 
998 |g 172250161  |a Martin, Eike  |m 172250161:Martin, Eike  |d 910000  |d 910300  |e 910000PM172250161  |e 910300PM172250161  |k 0/910000/  |k 1/910000/910300/  |p 7  |y j 
998 |g 1071847945  |a Fleischer, Franz  |m 1071847945:Fleischer, Franz  |d 910000  |d 910300  |e 910000PF1071847945  |e 910300PF1071847945  |k 0/910000/  |k 1/910000/910300/  |p 6 
998 |g 123544904  |a Soder, Michael  |m 123544904:Soder, Michael  |d 50000  |e 50000PS123544904  |k 0/50000/  |p 5 
998 |g 1059446626  |a Motsch, Johann  |m 1059446626:Motsch, Johann  |d 910000  |d 910300  |e 910000PM1059446626  |e 910300PM1059446626  |k 0/910000/  |k 1/910000/910300/  |p 4 
998 |g 1074896521  |a Böhrer, Hubert  |m 1074896521:Böhrer, Hubert  |d 910000  |d 910300  |e 910000PB1074896521  |e 910300PB1074896521  |k 0/910000/  |k 1/910000/910300/  |p 3 
998 |g 1059446510  |a Rauch, Helmut  |m 1059446510:Rauch, Helmut  |d 910000  |d 910300  |e 910000PR1059446510  |e 910300PR1059446510  |k 0/910000/  |k 1/910000/910300/  |p 2 
998 |g 1103463691  |a Böttiger, Bernd W.  |m 1103463691:Böttiger, Bernd W.  |d 910000  |d 910300  |e 910000PB1103463691  |e 910300PB1103463691  |k 0/910000/  |k 1/910000/910300/  |p 1  |x j 
999 |a KXP-PPN1888008628  |e 4521336191 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title":"Continuous versus intermittent cardiac output measurement in cardiac surgical patients undergoing hypothermic cardiopulmonary bypass","title_sort":"Continuous versus intermittent cardiac output measurement in cardiac surgical patients undergoing hypothermic cardiopulmonary bypass"}],"recId":"1888008628","relHost":[{"disp":"Continuous versus intermittent cardiac output measurement in cardiac surgical patients undergoing hypothermic cardiopulmonary bypassJournal of cardiothoracic and vascular anesthesia","pubHistory":["5.1991 -"],"title":[{"title_sort":"Journal of cardiothoracic and vascular anesthesia","title":"Journal of cardiothoracic and vascular anesthesia"}],"recId":"327643803","language":["eng"],"origin":[{"publisherPlace":"Philadelphia, Pa. ; New York, NY [u.a.]","publisher":"Saunders ; Elsevier","dateIssuedDisp":"1991-","dateIssuedKey":"1991"}],"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 19.01.06"],"type":{"media":"Online-Ressource","bibl":"periodical"},"id":{"issn":["1532-8422"],"eki":["327643803"],"zdb":["2043630-0"]},"part":{"extent":"7","issue":"4","pages":"405-411","volume":"9","year":"1995","text":"9(1995), 4, Seite 405-411"}}],"language":["eng"],"origin":[{"dateIssuedKey":"1995","dateIssuedDisp":"August 1995"}],"physDesc":[{"extent":"7 S."}],"person":[{"display":"Böttiger, Bernd W.","role":"aut","given":"Bernd W.","family":"Böttiger","roleDisplay":"VerfasserIn"},{"given":"Helmut","family":"Rauch","roleDisplay":"VerfasserIn","display":"Rauch, Helmut","role":"aut"},{"family":"Böhrer","given":"Hubert","roleDisplay":"VerfasserIn","display":"Böhrer, Hubert","role":"aut"},{"display":"Motsch, Johann","role":"aut","family":"Motsch","given":"Johann","roleDisplay":"VerfasserIn"},{"family":"Soder","given":"Michael","roleDisplay":"VerfasserIn","display":"Soder, Michael","role":"aut"},{"roleDisplay":"VerfasserIn","given":"Franz","family":"Fleischer","role":"aut","display":"Fleischer, Franz"},{"roleDisplay":"VerfasserIn","given":"Eike","family":"Martin","role":"aut","display":"Martin, Eike"}],"note":["Elektronische Reproduktion der Druck-Ausgabe 25. August 2005","Gesehen am 07.05.2024"],"name":{"displayForm":["Bernd W. Böttiger, Helmut Rauch, Hubert Böhrer, Johann Motsch, Michael Soder, Franz Fleischer, Eike Martin"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"doi":["10.1016/S1053-0770(05)80095-3"],"eki":["1888008628"]}} 
SRT |a BOETTIGERBCONTINUOUS1995