In vitro comparison of two electromagnetic shockwave generators: low-pressure wide focus vs high-pressure small focus: impact on initial stone fragmentation and final stone comminution
Context: Recently developed concepts for higher efficacy extracorporeal shockwave lithotripsy with low-pressure wide focus systems resulting in finer fragmentation of the calculi. - Objective: To compare two different electromagnetic shockwave sources (low-pressure wide focus [Xinin Lithotripter, XL...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
1 February 2022
|
| In: |
Journal of endourology
Year: 2022, Jahrgang: 36, Heft: 2, Pages: 266-272 |
| ISSN: | 1557-900X |
| DOI: | 10.1089/end.2021.0416 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1089/end.2021.0416 Verlag, lizenzpflichtig, Volltext: http://www.liebertpub.com/doi/10.1089/end.2021.0416 |
| Verfasserangaben: | Jens Rassweiler, Philip Rieker, Rainer Pecha, Martin Dressel, and Marie-Claire Rassweiler-Seyfried |
MARC
| LEADER | 00000caa a22000002c 4500 | ||
|---|---|---|---|
| 001 | 1888537892 | ||
| 003 | DE-627 | ||
| 005 | 20240703175815.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 240514s2022 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1089/end.2021.0416 |2 doi | |
| 035 | |a (DE-627)1888537892 | ||
| 035 | |a (DE-599)KXP1888537892 | ||
| 035 | |a (OCoLC)1443675755 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Rassweiler, Jens |d 1955- |e VerfasserIn |0 (DE-588)1067480307 |0 (DE-627)818791225 |0 (DE-576)426692713 |4 aut | |
| 245 | 1 | 0 | |a In vitro comparison of two electromagnetic shockwave generators: low-pressure wide focus vs high-pressure small focus |b impact on initial stone fragmentation and final stone comminution |c Jens Rassweiler, Philip Rieker, Rainer Pecha, Martin Dressel, and Marie-Claire Rassweiler-Seyfried |
| 246 | 3 | 3 | |a In vitro comparison of two electromagnetic shockwave generators: low-pressure wide focus versus high-pressure small focus |
| 264 | 1 | |c 1 February 2022 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 24.04.2024 | ||
| 520 | |a Context: Recently developed concepts for higher efficacy extracorporeal shockwave lithotripsy with low-pressure wide focus systems resulting in finer fragmentation of the calculi. - Objective: To compare two different electromagnetic shockwave sources (low-pressure wide focus [Xinin Lithotripter, XL] vs high-pressure small focus [Siemens Lithoskop, SL]) by sound field measurements and in vitro fragmentation. - Evidence Acquisition: The CS-2012A XX-ES lithotripter (self-focusing electromagnetic shockwave generator with concave spherical curved electrical coil; XL) was compared to the (SL) (electromagnetic generator with a flat electric coil with an acoustical lens). Different sound field measurements were performed using a fiber-optic hydrophone. Measurements at three different power settings (XL: 8.0, 9.3, and 10.3 kV and SL: Level 1, 5, and 8). Ten AST stones and 15 BegoStones (9.3 kV, Level 3) with a frequency of 90/minute (SL) and 20/minute (XL). Number of impulses to the first crack and for complete stone comminution (residual fragments <2 mm) was documented. - Results: The median number of shockwaves for the first crack in AST stones with the XL was 12 (10-14) and 7 with the SL (6-9). Complete disintegration was accomplished after 815 (782-824) shockwaves with XL and 702 (688-712) with SL. The difference was not statistically significant. The median number of shockwaves to produce the first crack in BegoStones was 524 (504-542) with XL and only 151 (137-161) with SL. Numbers of shockwaves for complete disintegration did not differ significantly (XL: 2518 vs SL: 2287). Using a wide focus with low pressure shows more homogeneous disintegration. - Conclusion: Two stone models showed significant differences regarding form and time of the initial fragmentation. Impulses for stone comminution did not differ significantly. The advantages of a low-pressure wide-focus system include minimal trauma and a homogeneous fragment size but is more time consuming. High-pressure small-focus systems are clinically effective. | ||
| 700 | 1 | |a Rieker, Philip |e VerfasserIn |0 (DE-588)1237001315 |0 (DE-627)176285645X |4 aut | |
| 700 | 1 | |a Pecha, Rainer |e VerfasserIn |4 aut | |
| 700 | 1 | |a Dressel, Martin |e VerfasserIn |4 aut | |
| 700 | 1 | |a Rassweiler-Seyfried, Marie-Claire |d 1986- |e VerfasserIn |0 (DE-588)1030330050 |0 (DE-627)735084637 |0 (DE-576)37812871X |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of endourology |d Larchmont, NY : Liebert, 1999 |g 36(2022), 2, Seite 266-272 |h Online-Ressource |w (DE-627)32482288X |w (DE-600)2030846-2 |w (DE-576)252074459 |x 1557-900X |7 nnas |a In vitro comparison of two electromagnetic shockwave generators: low-pressure wide focus vs high-pressure small focus impact on initial stone fragmentation and final stone comminution |
| 773 | 1 | 8 | |g volume:36 |g year:2022 |g number:2 |g pages:266-272 |g extent:7 |a In vitro comparison of two electromagnetic shockwave generators: low-pressure wide focus vs high-pressure small focus impact on initial stone fragmentation and final stone comminution |
| 856 | 4 | 0 | |u https://doi.org/10.1089/end.2021.0416 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u http://www.liebertpub.com/doi/10.1089/end.2021.0416 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20240514 | ||
| 993 | |a Article | ||
| 994 | |a 2022 | ||
| 998 | |g 1030330050 |a Rassweiler-Seyfried, Marie-Claire |m 1030330050:Rassweiler-Seyfried, Marie-Claire |d 60000 |d 63100 |e 60000PR1030330050 |e 63100PR1030330050 |k 0/60000/ |k 1/60000/63100/ |p 5 |y j | ||
| 998 | |g 1237001315 |a Rieker, Philip |m 1237001315:Rieker, Philip |d 60000 |e 60000PR1237001315 |k 0/60000/ |p 2 | ||
| 998 | |g 1067480307 |a Rassweiler, Jens |m 1067480307:Rassweiler, Jens |d 60000 |e 60000PR1067480307 |k 0/60000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1888537892 |e 4522843801 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"person":[{"family":"Rassweiler","display":"Rassweiler, Jens","roleDisplay":"VerfasserIn","given":"Jens","role":"aut"},{"roleDisplay":"VerfasserIn","given":"Philip","role":"aut","display":"Rieker, Philip","family":"Rieker"},{"role":"aut","given":"Rainer","roleDisplay":"VerfasserIn","display":"Pecha, Rainer","family":"Pecha"},{"role":"aut","roleDisplay":"VerfasserIn","given":"Martin","display":"Dressel, Martin","family":"Dressel"},{"family":"Rassweiler-Seyfried","display":"Rassweiler-Seyfried, Marie-Claire","role":"aut","roleDisplay":"VerfasserIn","given":"Marie-Claire"}],"physDesc":[{"extent":"7 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"recId":"1888537892","relHost":[{"pubHistory":["1.1987 -"],"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Journal of endourology","title_sort":"Journal of endourology"}],"origin":[{"dateIssuedKey":"1999","publisherPlace":"Larchmont, NY","publisher":"Liebert","dateIssuedDisp":"1999-"}],"disp":"In vitro comparison of two electromagnetic shockwave generators: low-pressure wide focus vs high-pressure small focus impact on initial stone fragmentation and final stone comminutionJournal of endourology","type":{"bibl":"periodical","media":"Online-Ressource"},"recId":"32482288X","language":["eng"],"part":{"issue":"2","text":"36(2022), 2, Seite 266-272","pages":"266-272","year":"2022","volume":"36","extent":"7"},"id":{"issn":["1557-900X"],"eki":["32482288X"],"zdb":["2030846-2"]}}],"id":{"eki":["1888537892"],"doi":["10.1089/end.2021.0416"]},"note":["Gesehen am 24.04.2024"],"title":[{"title":"In vitro comparison of two electromagnetic shockwave generators: low-pressure wide focus vs high-pressure small focus","title_sort":"In vitro comparison of two electromagnetic shockwave generators: low-pressure wide focus vs high-pressure small focus","subtitle":"impact on initial stone fragmentation and final stone comminution"}],"titleAlt":[{"title":"In vitro comparison of two electromagnetic shockwave generators: low-pressure wide focus versus high-pressure small focus"}],"origin":[{"dateIssuedKey":"2022","dateIssuedDisp":"1 February 2022"}],"name":{"displayForm":["Jens Rassweiler, Philip Rieker, Rainer Pecha, Martin Dressel, and Marie-Claire Rassweiler-Seyfried"]},"language":["eng"]} | ||
| SRT | |a RASSWEILERINVITROCOM1202 | ||