Augmented reality-supported rod bending in multilevel spinal fusion using the ADVISE Software

Background - One of the most common reasons for poor patient outcomes and revision surgery in spinal fusion is hardware failure. Screw loosening or pullout occurs in up to one-quarter of all cases. It is known that even small screw-rod misalignments can cause significant mechanical overloads during...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Antes, Sebastian (VerfasserIn) , Moringlane, Rene (VerfasserIn) , Eckardstein, Kajetan L. von (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: October 2023
In: World neurosurgery
Year: 2023, Jahrgang: 178, Pages: 96-100
ISSN:1878-8769
DOI:10.1016/j.wneu.2023.07.029
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.wneu.2023.07.029
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1878875023009555
Volltext
Verfasserangaben:Sebastian Antes, Rene Moringlane, Kajetan L. von Eckardstein

MARC

LEADER 00000caa a2200000 c 4500
001 1888979070
003 DE-627
005 20240703180341.0
007 cr uuu---uuuuu
008 240516s2023 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.wneu.2023.07.029  |2 doi 
035 |a (DE-627)1888979070 
035 |a (DE-599)KXP1888979070 
035 |a (OCoLC)1443678553 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Antes, Sebastian  |d 1983-  |e VerfasserIn  |0 (DE-588)142325562  |0 (DE-627)63553780X  |0 (DE-576)330127004  |4 aut 
245 1 0 |a Augmented reality-supported rod bending in multilevel spinal fusion using the ADVISE Software  |c Sebastian Antes, Rene Moringlane, Kajetan L. von Eckardstein 
264 1 |c October 2023 
300 |b Illustrationen 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online verfügbar: 16. Juli 2023, Artikelversion: 10. August 2023 
500 |a Gesehen am 16.05.2024 
520 |a Background - One of the most common reasons for poor patient outcomes and revision surgery in spinal fusion is hardware failure. Screw loosening or pullout occurs in up to one-quarter of all cases. It is known that even small screw-rod misalignments can cause significant mechanical overloads during rod fixation, which can result in hardware failure. To address this crucial surgical step, a novel augmented reality-assisted software was developed to generate custom rod templates that are precisely adapted to the individual patient. - Methods - The novel software, which runs on a tablet, is used in spinal fusion surgery and is based on the use of a specific pedicle screw system, in which the polyaxial screw heads are connected to detachable guides. These guides can be recognized by the tablet camera and a light detection and ranging scanner. This image information is processed to determine the spatial positions of the screw heads and to calculate an ideally fitting rod template. - Results - The calculated rod template is displayed in a 1-to-1 scale on the tablet screen. This template is used to cut and bend the rods of the pedicle screw system. Finally, the custom bent rod can be inserted into the screw heads without tension. - Conclusions - The augmented reality-assisted software is intended to give surgeons access to patient-specific intraoperative real-time data, helping them in bending rods that are more precisely adapted to the individual patient compared with the freehand technique. 
650 4 |a ADVISE 
650 4 |a Augmented reality 
650 4 |a iPad 
650 4 |a Pedicle screw system 
650 4 |a Rod bending 
700 1 |a Moringlane, Rene  |d 1981-  |e VerfasserIn  |0 (DE-588)104461899X  |0 (DE-627)772247838  |0 (DE-576)397987323  |4 aut 
700 1 |a Eckardstein, Kajetan L. von  |d 1972-  |e VerfasserIn  |0 (DE-588)122799097  |0 (DE-627)706048814  |0 (DE-576)293425604  |4 aut 
773 0 8 |i Enthalten in  |t World neurosurgery  |d Amsterdam : Elsevier, 2010  |g 178(2023), Seite 96-100  |h Online-Ressource  |w (DE-627)615134904  |w (DE-600)2530041-6  |w (DE-576)321461150  |x 1878-8769  |7 nnas  |a Augmented reality-supported rod bending in multilevel spinal fusion using the ADVISE Software 
773 1 8 |g volume:178  |g year:2023  |g pages:96-100  |g extent:5  |a Augmented reality-supported rod bending in multilevel spinal fusion using the ADVISE Software 
856 4 0 |u https://doi.org/10.1016/j.wneu.2023.07.029  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1878875023009555  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20240516 
993 |a Article 
994 |a 2023 
998 |g 122799097  |a Eckardstein, Kajetan L. von  |m 122799097:Eckardstein, Kajetan L. von  |d 60000  |e 60000PE122799097  |k 0/60000/  |p 3  |y j 
999 |a KXP-PPN1888979070  |e 452439981X 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Sebastian Antes, Rene Moringlane, Kajetan L. von Eckardstein"]},"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"October 2023"}],"id":{"doi":["10.1016/j.wneu.2023.07.029"],"eki":["1888979070"]},"physDesc":[{"extent":"5 S.","noteIll":"Illustrationen"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"dateIssuedKey":"2010","publisher":"Elsevier","dateIssuedDisp":"2010-","publisherPlace":"Amsterdam"}],"id":{"issn":["1878-8769"],"eki":["615134904"],"zdb":["2530041-6"]},"note":["Gesehen am 20.03.25"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Augmented reality-supported rod bending in multilevel spinal fusion using the ADVISE SoftwareWorld neurosurgery","recId":"615134904","language":["eng"],"pubHistory":["73.2010 -"],"part":{"pages":"96-100","year":"2023","extent":"5","text":"178(2023), Seite 96-100","volume":"178"},"title":[{"title":"World neurosurgery","title_sort":"World neurosurgery"}]}],"person":[{"display":"Antes, Sebastian","roleDisplay":"VerfasserIn","role":"aut","family":"Antes","given":"Sebastian"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Moringlane, Rene","given":"Rene","family":"Moringlane"},{"family":"Eckardstein","given":"Kajetan L. von","display":"Eckardstein, Kajetan L. von","roleDisplay":"VerfasserIn","role":"aut"}],"title":[{"title_sort":"Augmented reality-supported rod bending in multilevel spinal fusion using the ADVISE Software","title":"Augmented reality-supported rod bending in multilevel spinal fusion using the ADVISE Software"}],"note":["Online verfügbar: 16. Juli 2023, Artikelversion: 10. August 2023","Gesehen am 16.05.2024"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"recId":"1888979070","language":["eng"]} 
SRT |a ANTESSEBASAUGMENTEDR2023