Acute efficacy and chronic follow-up of patients with non-thoracotomy third generation implantahle defibrillators

Non-thoracotomy implantation of implantable cardioverter defibrillators (ICDs) has simplified the process of device inserfion, promising to decrease associated procedural coniplications while providing sudden death protection at least equal to epicardial systems. This study presents the acute and ch...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Brachmann, Johannes (VerfasserIn) , Sterns, Laurence D. (VerfasserIn) , Hilbel, Thomas (VerfasserIn) , Schöls, Wolfgang (VerfasserIn) , Beyer, Thorsten (VerfasserIn) , Mehmanesh, Hormoz (VerfasserIn) , Lange, Rüdiger (VerfasserIn) , Ruf-Richter, Jutta (VerfasserIn) , Kraft, Patricia (VerfasserIn) , Hagl, Siegfried (VerfasserIn) , Kübler, Wolfgang (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: March 1994
In: Pacing and clinical electrophysiology
Year: 1994, Jahrgang: 17, Heft: 3, Pages: 499-505
ISSN:1540-8159
DOI:10.1111/j.1540-8159.1994.tb01417.x
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1111/j.1540-8159.1994.tb01417.x
Verlag, lizenzpflichtig, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1540-8159.1994.tb01417.x
Volltext
Verfasserangaben:Johannes Brachmann, Laurence D. Sterns, Thomas Hilbel, Wolfgang Schöls, Thorsten Beyer, Hormoz Mehmanesh, Rüdiger Lange, Jutta Ruf-Richter, Patricia Kraft, Siegfried Hagl, Wolfgang Kübler

MARC

LEADER 00000caa a2200000 c 4500
001 1889903388
003 DE-627
005 20251029094957.0
007 cr uuu---uuuuu
008 240527s1994 xx |||||o 00| ||eng c
024 7 |a 10.1111/j.1540-8159.1994.tb01417.x  |2 doi 
035 |a (DE-627)1889903388 
035 |a (DE-599)KXP1889903388 
035 |a (OCoLC)1443679079 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Brachmann, Johannes  |e VerfasserIn  |0 (DE-588)171987209  |0 (DE-627)696882957  |0 (DE-576)132863677  |4 aut 
245 1 0 |a Acute efficacy and chronic follow-up of patients with non-thoracotomy third generation implantahle defibrillators  |c Johannes Brachmann, Laurence D. Sterns, Thomas Hilbel, Wolfgang Schöls, Thorsten Beyer, Hormoz Mehmanesh, Rüdiger Lange, Jutta Ruf-Richter, Patricia Kraft, Siegfried Hagl, Wolfgang Kübler 
264 1 |c March 1994 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Elektronische Reproduktion der Druck-Ausgabe 30. Juni 2006 
500 |a Gesehen am 27.05.2024 
520 |a Non-thoracotomy implantation of implantable cardioverter defibrillators (ICDs) has simplified the process of device inserfion, promising to decrease associated procedural coniplications while providing sudden death protection at least equal to epicardial systems. This study presents the acute and chronic results of 110 patients who underwent attempted non-thoracotomy ICD impiuntation wiih the Medtronic Transvene lead system and PCD model 7217 or 7219. Of the 110 patients attempted, 100 (91%) had the system successfully implanted without the need for an epicar-dial patch. One patient died 1 week postoperatively of septic shock related to the implantation (0.9% perioperative mortality). During folloiv-up of 16 ± 11 months, 45% of the patients had an event detected as ventricular tachycardia; 26% of these detections were felt clinically to be due to supraventricular rhythms. Of the remainder, 87% were successfully treated with the first VT therapy, and 98% were terminated by the final therapy; 66% of the patients had at least one episode of ventricular fibrillation, of which 5% were felt to be inappropriate detections; 65% of the appropriate episodes were successfully treated with the first VF therapy, and all were converted by the final therapy. Total mortality at 6, 12, and 24 months was 3%, 11%, and 19% respectively. Only one patient had sudden cardiac death, occurring at 13 months postimplant. Overall, the non-thoracotomy lead system for this ICD displayed infrequent implant complications and proved to be reliable ai terminating arrhythmias and maintaining a low rate of sudden cardiac death in this high risk popuiation. 
650 4 |a implantable defibrillator 
650 4 |a non-thoracotomy leads 
650 4 |a ventricular fibrillation 
650 4 |a ventricular tachycardia 
700 1 |a Sterns, Laurence D.  |e VerfasserIn  |4 aut 
700 1 |a Hilbel, Thomas  |e VerfasserIn  |0 (DE-588)1137490373  |0 (DE-627)894682075  |0 (DE-576)169697010  |4 aut 
700 1 |a Schöls, Wolfgang  |e VerfasserIn  |0 (DE-588)1169666906  |0 (DE-627)1035865653  |0 (DE-576)512179719  |4 aut 
700 1 |a Beyer, Thorsten  |e VerfasserIn  |0 (DE-588)1324565241  |0 (DE-627)1884470432  |4 aut 
700 1 |a Mehmanesh, Hormoz  |e VerfasserIn  |4 aut 
700 1 |a Lange, Rüdiger  |d 1953-  |e VerfasserIn  |0 (DE-588)131649507  |0 (DE-627)707694663  |0 (DE-576)298649276  |4 aut 
700 1 |a Ruf-Richter, Jutta  |e VerfasserIn  |4 aut 
700 1 |a Kraft, Patricia  |e VerfasserIn  |0 (DE-588)1241910367  |0 (DE-627)1771802006  |4 aut 
700 1 |a Hagl, Siegfried  |e VerfasserIn  |0 (DE-588)1076770274  |0 (DE-627)835318354  |0 (DE-576)445655224  |4 aut 
700 1 |a Kübler, Wolfgang  |d 1934-2019  |e VerfasserIn  |0 (DE-588)1111662983  |0 (DE-627)865837201  |0 (DE-576)476228638  |4 aut 
773 0 8 |i Enthalten in  |t Pacing and clinical electrophysiology  |d New York, NY [u.a.] : Wiley-Blackwell, 1978  |g 17(1994), 3, Seite 499-505  |h Online-Ressource  |w (DE-627)325572267  |w (DE-600)2037547-5  |w (DE-576)094108501  |x 1540-8159  |7 nnas  |a Acute efficacy and chronic follow-up of patients with non-thoracotomy third generation implantahle defibrillators 
773 1 8 |g volume:17  |g year:1994  |g number:3  |g pages:499-505  |g extent:7  |a Acute efficacy and chronic follow-up of patients with non-thoracotomy third generation implantahle defibrillators 
856 4 0 |u https://doi.org/10.1111/j.1540-8159.1994.tb01417.x  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1540-8159.1994.tb01417.x  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20240527 
993 |a Article 
994 |a 1994 
998 |g 1111662983  |a Kübler, Wolfgang  |m 1111662983:Kübler, Wolfgang  |d 910000  |d 910100  |e 910000PK1111662983  |e 910100PK1111662983  |k 0/910000/  |k 1/910000/910100/  |p 11  |y j 
998 |g 1076770274  |a Hagl, Siegfried  |m 1076770274:Hagl, Siegfried  |d 910000  |d 910200  |e 910000PH1076770274  |e 910200PH1076770274  |k 0/910000/  |k 1/910000/910200/  |p 10 
998 |g 131649507  |a Lange, Rüdiger  |m 131649507:Lange, Rüdiger  |d 910000  |d 910200  |e 910000PL131649507  |e 910200PL131649507  |k 0/910000/  |k 1/910000/910200/  |p 7 
998 |g 1324565241  |a Beyer, Thorsten  |m 1324565241:Beyer, Thorsten  |d 50000  |e 50000PB1324565241  |k 0/50000/  |p 5 
998 |g 1169666906  |a Schöls, Wolfgang  |m 1169666906:Schöls, Wolfgang  |d 910000  |d 910100  |e 910000PS1169666906  |e 910100PS1169666906  |k 0/910000/  |k 1/910000/910100/  |p 4 
998 |g 1137490373  |a Hilbel, Thomas  |m 1137490373:Hilbel, Thomas  |d 910000  |d 910100  |e 910000PH1137490373  |e 910100PH1137490373  |k 0/910000/  |k 1/910000/910100/  |p 3 
998 |g 171987209  |a Brachmann, Johannes  |m 171987209:Brachmann, Johannes  |d 910000  |d 910100  |e 910000PB171987209  |e 910100PB171987209  |k 0/910000/  |k 1/910000/910100/  |p 1  |x j 
999 |a KXP-PPN1889903388  |e 4529970116 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1889903388"],"doi":["10.1111/j.1540-8159.1994.tb01417.x"]},"name":{"displayForm":["Johannes Brachmann, Laurence D. Sterns, Thomas Hilbel, Wolfgang Schöls, Thorsten Beyer, Hormoz Mehmanesh, Rüdiger Lange, Jutta Ruf-Richter, Patricia Kraft, Siegfried Hagl, Wolfgang Kübler"]},"recId":"1889903388","physDesc":[{"extent":"7 S."}],"title":[{"title_sort":"Acute efficacy and chronic follow-up of patients with non-thoracotomy third generation implantahle defibrillators","title":"Acute efficacy and chronic follow-up of patients with non-thoracotomy third generation implantahle defibrillators"}],"note":["Elektronische Reproduktion der Druck-Ausgabe 30. Juni 2006","Gesehen am 27.05.2024"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"relHost":[{"pubHistory":["1.1978 -"],"titleAlt":[{"title":"PACE"}],"part":{"extent":"7","text":"17(1994), 3, Seite 499-505","issue":"3","pages":"499-505","volume":"17","year":"1994"},"id":{"doi":["10.1111/(ISSN)1540-8159"],"zdb":["2037547-5"],"issn":["1540-8159","1468-0106"],"eki":["325572267"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"325572267","disp":"Acute efficacy and chronic follow-up of patients with non-thoracotomy third generation implantahle defibrillatorsPacing and clinical electrophysiology","origin":[{"dateIssuedKey":"1978","publisherPlace":"New York, NY [u.a.] ; New York, NY [u.a.]","dateIssuedDisp":"1978-","publisher":"Wiley-Blackwell ; Blackwell Publ."}],"note":["Gesehen am 12.04.2022"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"subtitle":"PACE ; official journal of the International Cardiac Pacing and Electrophysiology Society","title_sort":"Pacing and clinical electrophysiology","title":"Pacing and clinical electrophysiology"}]}],"person":[{"display":"Brachmann, Johannes","role":"aut","given":"Johannes","family":"Brachmann"},{"display":"Sterns, Laurence D.","family":"Sterns","role":"aut","given":"Laurence D."},{"family":"Hilbel","role":"aut","given":"Thomas","display":"Hilbel, Thomas"},{"display":"Schöls, Wolfgang","family":"Schöls","role":"aut","given":"Wolfgang"},{"family":"Beyer","role":"aut","given":"Thorsten","display":"Beyer, Thorsten"},{"role":"aut","given":"Hormoz","family":"Mehmanesh","display":"Mehmanesh, Hormoz"},{"display":"Lange, Rüdiger","given":"Rüdiger","role":"aut","family":"Lange"},{"display":"Ruf-Richter, Jutta","given":"Jutta","role":"aut","family":"Ruf-Richter"},{"display":"Kraft, Patricia","family":"Kraft","role":"aut","given":"Patricia"},{"family":"Hagl","given":"Siegfried","role":"aut","display":"Hagl, Siegfried"},{"role":"aut","given":"Wolfgang","family":"Kübler","display":"Kübler, Wolfgang"}],"origin":[{"dateIssuedDisp":"March 1994","dateIssuedKey":"1994"}]} 
SRT |a BRACHMANNJACUTEEFFIC1994