Interaction between CIEDs and modern radiotherapy techniques: flattening filter free-VMAT, dose-rate effects, scatter radiation, and neutron-generating energies
Background and purpose - Providing evidence for radiotherapy (RT)-induced effects on cardiac implantable electric devices (CIEDs) with focus on flattening filter free-volumetric modulated arc therapy (FFF-VMAT) at 6 and 10 MV as well as 3D-conformal radiotherapy (3D-CRT) at 18 MV. - Materials and me...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
November 2020
|
| In: |
Radiotherapy and oncology
Year: 2020, Jahrgang: 152, Pages: 196-202 |
| ISSN: | 1879-0887 |
| DOI: | 10.1016/j.radonc.2019.12.007 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.radonc.2019.12.007 Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0167814019335078 |
| Verfasserangaben: | Benjamin Gauter-Fleckenstein, Julia Nguyen, Lennart Jahnke, Timo Gaiser, Boris Rudic, Sylvia Büttner, Frederik Wenz, Martin Borggrefe, Erol Tülümen |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1890393711 | ||
| 003 | DE-627 | ||
| 005 | 20240716162440.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 240531s2020 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.radonc.2019.12.007 |2 doi | |
| 035 | |a (DE-627)1890393711 | ||
| 035 | |a (DE-599)KXP1890393711 | ||
| 035 | |a (OCoLC)1443679277 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Gauter-Fleckenstein, Benjamin |d 1971- |e VerfasserIn |0 (DE-588)123732336 |0 (DE-627)70641022X |0 (DE-576)293850240 |4 aut | |
| 245 | 1 | 0 | |a Interaction between CIEDs and modern radiotherapy techniques |b flattening filter free-VMAT, dose-rate effects, scatter radiation, and neutron-generating energies |c Benjamin Gauter-Fleckenstein, Julia Nguyen, Lennart Jahnke, Timo Gaiser, Boris Rudic, Sylvia Büttner, Frederik Wenz, Martin Borggrefe, Erol Tülümen |
| 264 | 1 | |c November 2020 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 31.05.2023 | ||
| 520 | |a Background and purpose - Providing evidence for radiotherapy (RT)-induced effects on cardiac implantable electric devices (CIEDs) with focus on flattening filter free-volumetric modulated arc therapy (FFF-VMAT) at 6 and 10 MV as well as 3D-conformal radiotherapy (3D-CRT) at 18 MV. - Materials and methods - 68 CIEDs (64 implantable cardioverter-defibrillators (ICDs) and 4 cardiac pacemakers (PMs)) were located on the left chest position on a slab phantom and irradiated under telemetrical surveillance either directly, or distant to 3D-CRT or FFF-VMAT, dose-rate 2500 cGy/min, and target dose of 150 Gy. Devices were placed within, close by (2.5 cm and 5 cm), and distant (35 cm) to the radiation field. Scatter radiation (SR) and photon neutrons (PN) were recorded. CIEDs were investigated in following groups: 1a) 18 MV 3D-CRT − 4 ICDs/4 PMs out of radiation field, 1b) 18 MV open field − 4 ICDs/4 PMs within radiation field, 2) 6 MV FFF-VMAT, 15 ICDs in 35 cm distance to VMAT, 3) 10 MV-FFF VMAT, 15 ICDs in 35 cm distance to VMAT, 4) 6 MV FFF-VMAT, 15 ICDs in 2.5 cm distance to VMAT, 5) 10 MV FFF-VMAT, 15 ICDs in 2.5 cm distance to VMAT. - Results - No incidents occurred at 6 MV FFF. 10 MV FFF-VMAT and 18 MV 3D-CRT resulted in data loss, reset, and erroneous sensing with inhibition of pacing (leading to inadequate defibrillation) in 8/34 ICDs and 2/4 PMs which were not located within radiation. Direct radiation triggered instantaneous defibrillation in 3/4 ICDs. - Conclusions - 6 MV FFF-VMAT is safe even at high dose-rates of 2500 cGy/min, regardless whether CIEDs are located close (2.5 cm) or distant (35 cm) to the radiation beam. CIEDs should never be placed within radiation and energy should always be limited to 6 MV. At 6 MV, VMAT at high dose-rates can be used to treat tumors, which are located close to CIEDs. | ||
| 650 | 4 | |a Cardiac pacemaker | |
| 650 | 4 | |a Dose-rate effects | |
| 650 | 4 | |a Flattening filter free-VMAT | |
| 650 | 4 | |a Implantable cardioverter-defibrillator | |
| 650 | 4 | |a Neutron-generating energies | |
| 650 | 4 | |a Scatter radiation | |
| 700 | 1 | |a Nguyen, Julia |d 1993- |e VerfasserIn |0 (DE-588)1243032715 |0 (DE-627)1782682961 |4 aut | |
| 700 | 1 | |a Jahnke, Lennart |e VerfasserIn |0 (DE-588)1029119066 |0 (DE-627)732701805 |0 (DE-576)376584653 |4 aut | |
| 700 | 1 | |a Gaiser, Timo |d 1975- |e VerfasserIn |0 (DE-588)1030402280 |0 (DE-627)735221685 |0 (DE-576)378226533 |4 aut | |
| 700 | 1 | |a Rudic, Boris |d 1982- |e VerfasserIn |0 (DE-588)1024726789 |0 (DE-627)720427134 |0 (DE-576)369410599 |4 aut | |
| 700 | 1 | |a Büttner, Sylvia |d 1962- |e VerfasserIn |0 (DE-588)1038291364 |0 (DE-627)75693611X |0 (DE-576)392282550 |4 aut | |
| 700 | 1 | |a Wenz, Frederik |d 1966- |e VerfasserIn |0 (DE-588)113310390 |0 (DE-627)663837766 |0 (DE-576)346656281 |4 aut | |
| 700 | 1 | |a Borggrefe, Martin |e VerfasserIn |0 (DE-588)1025920546 |0 (DE-627)725574232 |0 (DE-576)370913426 |4 aut | |
| 700 | 1 | |a Tueluemen, Erol |e VerfasserIn |0 (DE-588)1035228955 |0 (DE-627)746999585 |0 (DE-576)382840534 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Radiotherapy and oncology |d Amsterdam [u.a.] : Elsevier Science, 1983 |g 152(2020) vom: Nov., Seite 196-202 |h Online-Ressource |w (DE-627)306710110 |w (DE-600)1500707-8 |w (DE-576)082435731 |x 1879-0887 |7 nnas |a Interaction between CIEDs and modern radiotherapy techniques flattening filter free-VMAT, dose-rate effects, scatter radiation, and neutron-generating energies |
| 773 | 1 | 8 | |g volume:152 |g year:2020 |g month:11 |g pages:196-202 |g extent:7 |a Interaction between CIEDs and modern radiotherapy techniques flattening filter free-VMAT, dose-rate effects, scatter radiation, and neutron-generating energies |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.radonc.2019.12.007 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S0167814019335078 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20240531 | ||
| 993 | |a Article | ||
| 994 | |a 2020 | ||
| 998 | |g 1035228955 |a Tueluemen, Erol |m 1035228955:Tueluemen, Erol |d 60000 |e 60000PT1035228955 |k 0/60000/ |p 9 |y j | ||
| 998 | |g 1025920546 |a Borggrefe, Martin |m 1025920546:Borggrefe, Martin |d 60000 |d 61000 |e 60000PB1025920546 |e 61000PB1025920546 |k 0/60000/ |k 1/60000/61000/ |p 8 | ||
| 998 | |g 113310390 |a Wenz, Frederik |m 113310390:Wenz, Frederik |d 60000 |e 60000PW113310390 |k 0/60000/ |p 7 | ||
| 998 | |g 1038291364 |a Büttner, Sylvia |m 1038291364:Büttner, Sylvia |d 60000 |d 60200 |d 60250 |e 60000PB1038291364 |e 60200PB1038291364 |e 60250PB1038291364 |k 0/60000/ |k 1/60000/60200/ |k 2/60000/60200/60250/ |p 6 | ||
| 998 | |g 1024726789 |a Rudic, Boris |m 1024726789:Rudic, Boris |d 60000 |e 60000PR1024726789 |k 0/60000/ |p 5 | ||
| 998 | |g 1030402280 |a Gaiser, Timo |m 1030402280:Gaiser, Timo |p 4 | ||
| 998 | |g 1243032715 |a Nguyen, Julia |m 1243032715:Nguyen, Julia |d 60000 |e 60000PN1243032715 |k 0/60000/ |p 2 | ||
| 998 | |g 123732336 |a Gauter-Fleckenstein, Benjamin |m 123732336:Gauter-Fleckenstein, Benjamin |d 60000 |e 60000PG123732336 |k 0/60000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1890393711 |e 453233084X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"note":["Gesehen am 30.05.15","Ungezählte Beil.: Supplement"],"part":{"text":"152(2020) vom: Nov., Seite 196-202","volume":"152","pages":"196-202","year":"2020","extent":"7"},"id":{"eki":["306710110"],"zdb":["1500707-8"],"issn":["1879-0887"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"subtitle":"journal of the European Society for Therapeutic Radiology and Oncology","title_sort":"Radiotherapy and oncology","title":"Radiotherapy and oncology"}],"origin":[{"dateIssuedKey":"1983","publisherPlace":"Amsterdam [u.a.]","publisher":"Elsevier Science","dateIssuedDisp":"1983-"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["1.1983 -"],"titleAlt":[{"title":"The green journal"}],"language":["eng"],"recId":"306710110","disp":"Interaction between CIEDs and modern radiotherapy techniques flattening filter free-VMAT, dose-rate effects, scatter radiation, and neutron-generating energiesRadiotherapy and oncology"}],"note":["Gesehen am 31.05.2023"],"physDesc":[{"extent":"7 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"doi":["10.1016/j.radonc.2019.12.007"],"eki":["1890393711"]},"language":["eng"],"title":[{"title_sort":"Interaction between CIEDs and modern radiotherapy techniques","subtitle":"flattening filter free-VMAT, dose-rate effects, scatter radiation, and neutron-generating energies","title":"Interaction between CIEDs and modern radiotherapy techniques"}],"person":[{"family":"Gauter-Fleckenstein","display":"Gauter-Fleckenstein, Benjamin","given":"Benjamin","role":"aut"},{"role":"aut","given":"Julia","display":"Nguyen, Julia","family":"Nguyen"},{"role":"aut","display":"Jahnke, Lennart","given":"Lennart","family":"Jahnke"},{"given":"Timo","display":"Gaiser, Timo","family":"Gaiser","role":"aut"},{"family":"Rudic","display":"Rudic, Boris","given":"Boris","role":"aut"},{"role":"aut","display":"Büttner, Sylvia","given":"Sylvia","family":"Büttner"},{"family":"Wenz","display":"Wenz, Frederik","given":"Frederik","role":"aut"},{"role":"aut","family":"Borggrefe","given":"Martin","display":"Borggrefe, Martin"},{"display":"Tueluemen, Erol","given":"Erol","family":"Tueluemen","role":"aut"}],"recId":"1890393711","name":{"displayForm":["Benjamin Gauter-Fleckenstein, Julia Nguyen, Lennart Jahnke, Timo Gaiser, Boris Rudic, Sylvia Büttner, Frederik Wenz, Martin Borggrefe, Erol Tülümen"]},"origin":[{"dateIssuedKey":"2020","dateIssuedDisp":"November 2020"}]} | ||
| SRT | |a GAUTERFLECINTERACTIO2020 | ||