Effect of scan-path length on the scanning accuracy of completely dentate and partially edentulous maxillae

Statement of problem - The accuracy of fit of fixed partial dentures is directly dependent on the accuracy of a digital scan. However, the influence of scan-path length on scanning accuracy is unclear. - Purpose - The purpose of this in vitro study was to evaluate how scan-path length influenced the...

Full description

Saved in:
Bibliographic Details
Main Authors: Waldecker, Moritz (Author) , Rues, Stefan (Author) , Behnisch, Rouven (Author) , Rammelsberg, Peter (Author) , Bömicke, Wolfgang (Author)
Format: Article (Journal)
Language:English
Published: January 2024
In: The journal of prosthetic dentistry
Year: 2024, Volume: 131, Issue: 1, Pages: 146-154
ISSN:1097-6841
DOI:10.1016/j.prosdent.2022.02.016
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.prosdent.2022.02.016
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S002239132200141X
Get full text
Author Notes:Moritz Waldecker, Stefan Rues, Rouven Behnisch, Peter Rammelsberg, Wolfgang Bömicke

MARC

LEADER 00000caa a2200000 c 4500
001 1890496898
003 DE-627
005 20250325181801.0
007 cr uuu---uuuuu
008 240603s2024 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.prosdent.2022.02.016  |2 doi 
035 |a (DE-627)1890496898 
035 |a (DE-599)KXP1890496898 
035 |a (OCoLC)1443679026 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Waldecker, Moritz  |d 1986-  |e VerfasserIn  |0 (DE-588)114780172X  |0 (DE-627)1007199024  |0 (DE-576)496051652  |4 aut 
245 1 0 |a Effect of scan-path length on the scanning accuracy of completely dentate and partially edentulous maxillae  |c Moritz Waldecker, Stefan Rues, Rouven Behnisch, Peter Rammelsberg, Wolfgang Bömicke 
264 1 |c January 2024 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 03.06.2024 
520 |a Statement of problem - The accuracy of fit of fixed partial dentures is directly dependent on the accuracy of a digital scan. However, the influence of scan-path length on scanning accuracy is unclear. - Purpose - The purpose of this in vitro study was to evaluate how scan-path length influenced the scanning accuracy of a completely dentate or partially edentulous maxilla captured by 3 intraoral scanners: Omnicam AC (OC), TRIOS 4 (TR), and Primescan (PS). - Material and methods - Each intraoral scanner was used to make 30 scans each of the 2 clinical scenarios (completely dentate and partially edentulous) simulated with a reference model. The partially edentulous model simulated a maxilla with 6 prepared teeth to support a complete arch fixed partial denture. The missing teeth were then added to create a completely dentate model. The prepared teeth were later used to determine distance, angular, and tooth-axis deviations between the reference model (digitized with high precision before the tests) and the intraoral scans. Data were statistically analyzed by using a linear model or, if not applicable, a type II ANOVA (α=.05). - Results - Distance deviations increased linearly as the scan-path length increased. In contrast, angular and tooth-axis deviations did not increase linearly. All types of deviation differed depending on the scanning system used. Regarding the 90% quantile values, total distance deviations related to scan-path length amounted to 1.31 μm/mm (OC), 1.00 μm/mm (PS), and 1.45 μm/mm (TR) for the completely dentate maxilla and 1.10 μm/mm (OC), 1.46 μm/mm (PS), and 1.40 μm/mm (TR) for the partially edentulous maxilla. - Conclusions - Distance deviations became larger as the scan-path length increased. 
700 1 |a Rues, Stefan  |e VerfasserIn  |0 (DE-588)1054444927  |0 (DE-627)792098331  |0 (DE-576)410292168  |4 aut 
700 1 |a Behnisch, Rouven  |d 1990-  |e VerfasserIn  |0 (DE-588)1191206238  |0 (DE-627)1669619265  |4 aut 
700 1 |a Rammelsberg, Peter  |d 1959-  |e VerfasserIn  |0 (DE-588)122469836  |0 (DE-627)705920836  |0 (DE-576)293285640  |4 aut 
700 1 |a Bömicke, Wolfgang  |d 1981-  |e VerfasserIn  |0 (DE-588)1015022146  |0 (DE-627)668338792  |0 (DE-576)349947651  |4 aut 
773 0 8 |i Enthalten in  |t The journal of prosthetic dentistry  |d London [u.a.] : Elsevier, 1951  |g 131(2024), 1 vom: Jan., Seite 146-154  |h Online-Ressource  |w (DE-627)320495787  |w (DE-600)2011581-7  |w (DE-576)09101509X  |x 1097-6841  |7 nnas  |a Effect of scan-path length on the scanning accuracy of completely dentate and partially edentulous maxillae 
773 1 8 |g volume:131  |g year:2024  |g number:1  |g month:01  |g pages:146-154  |g extent:9  |a Effect of scan-path length on the scanning accuracy of completely dentate and partially edentulous maxillae 
856 4 0 |u https://doi.org/10.1016/j.prosdent.2022.02.016  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S002239132200141X  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20240603 
993 |a Article 
994 |a 2024 
998 |g 1015022146  |a Bömicke, Wolfgang  |m 1015022146:Bömicke, Wolfgang  |d 910000  |d 910800  |d 50000  |e 910000PB1015022146  |e 910800PB1015022146  |e 50000PB1015022146  |k 0/910000/  |k 1/910000/910800/  |k 0/50000/  |p 5  |y j 
998 |g 122469836  |a Rammelsberg, Peter  |m 122469836:Rammelsberg, Peter  |d 910000  |d 910800  |e 910000PR122469836  |e 910800PR122469836  |k 0/910000/  |k 1/910000/910800/  |p 4 
998 |g 1191206238  |a Behnisch, Rouven  |m 1191206238:Behnisch, Rouven  |d 910000  |d 911800  |e 910000PB1191206238  |e 911800PB1191206238  |k 0/910000/  |k 1/910000/911800/  |p 3 
998 |g 1054444927  |a Rues, Stefan  |m 1054444927:Rues, Stefan  |d 910000  |d 910800  |e 910000PR1054444927  |e 910800PR1054444927  |k 0/910000/  |k 1/910000/910800/  |p 2 
998 |g 114780172X  |a Waldecker, Moritz  |m 114780172X:Waldecker, Moritz  |d 910000  |d 910800  |e 910000PW114780172X  |e 910800PW114780172X  |k 0/910000/  |k 1/910000/910800/  |p 1  |x j 
999 |a KXP-PPN1890496898  |e 4533769055 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Moritz Waldecker, Stefan Rues, Rouven Behnisch, Peter Rammelsberg, Wolfgang Bömicke"]},"note":["Gesehen am 03.06.2024"],"recId":"1890496898","person":[{"role":"aut","display":"Waldecker, Moritz","family":"Waldecker","given":"Moritz"},{"display":"Rues, Stefan","family":"Rues","given":"Stefan","role":"aut"},{"given":"Rouven","family":"Behnisch","display":"Behnisch, Rouven","role":"aut"},{"role":"aut","family":"Rammelsberg","display":"Rammelsberg, Peter","given":"Peter"},{"role":"aut","family":"Bömicke","display":"Bömicke, Wolfgang","given":"Wolfgang"}],"physDesc":[{"extent":"9 S."}],"title":[{"title_sort":"Effect of scan-path length on the scanning accuracy of completely dentate and partially edentulous maxillae","title":"Effect of scan-path length on the scanning accuracy of completely dentate and partially edentulous maxillae"}],"relHost":[{"origin":[{"dateIssuedDisp":"1951-","publisherPlace":"London [u.a.] ; St. Louis, Mo.","dateIssuedKey":"1951","publisher":"Elsevier ; Mosby"}],"id":{"issn":["1097-6841"],"zdb":["2011581-7"],"eki":["320495787"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"part":{"volume":"131","pages":"146-154","text":"131(2024), 1 vom: Jan., Seite 146-154","year":"2024","extent":"9","issue":"1"},"physDesc":[{"extent":"Online-Ressource"}],"titleAlt":[{"title":"JPD"}],"title":[{"title_sort":"journal of prosthetic dentistry","title":"The journal of prosthetic dentistry"}],"disp":"Effect of scan-path length on the scanning accuracy of completely dentate and partially edentulous maxillaeThe journal of prosthetic dentistry","pubHistory":["1.1951 -"],"recId":"320495787","note":["Gesehen am 07.08.25"]}],"id":{"eki":["1890496898"],"doi":["10.1016/j.prosdent.2022.02.016"]},"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedDisp":"January 2024","dateIssuedKey":"2024"}]} 
SRT |a WALDECKERMEFFECTOFSC2024