A phantom to simulate organ motion and its effect on dose distribution in carbon ion therapy for pancreatic cancer

Objective. Carbon ion radiotherapy is a promising radiation technique for malignancies like pancreatic cancer. However, organs’ motion imposes challenges for achieving homogeneous dose delivery. In this study, an anthropomorphic Pancreas Phantom for Ion-beam Therapy (PPIeT) was developed to simulate...

Full description

Saved in:
Bibliographic Details
Main Authors: Stengl, Christina (Author) , Panow, Kathrin (Author) , Arbes, Eric (Author) , Muñoz, Iván Domingo (Author) , Christensen, Jeppe Brage (Author) , Neelsen, Christian (Author) , Dinkel, Fabian (Author) , Weidner, Artur (Author) , Runz, Armin (Author) , Johnen, Wibke (Author) , Liermann, Jakob (Author) , Echner, Gernot (Author) , Vedelago, José (Author) , Jäkel, Oliver (Author)
Format: Article (Journal)
Language:English
Published: 11 December 2023
In: Physics in medicine and biology
Year: 2023, Volume: 68, Issue: 24, Pages: 1-15
ISSN:1361-6560
DOI:10.1088/1361-6560/ad0902
Online Access:Resolving-System, kostenfrei, Volltext: https://doi.org/10.1088/1361-6560/ad0902
Verlag, lizenzpflichtig, Volltext: https://dx.doi.org/10.1088/1361-6560/ad0902
Get full text
Author Notes:Christina Stengl, Kathrin Panow, Eric Arbes, Iván D. Muñoz, Jeppe B. Christensen, Christian Neelsen, Fabian Dinkel, Artur Weidner, Armin Runz, Wibke Johnen, Jakob Liermann, Gernot Echner, José Vedelago, Oliver Jäkel

MARC

LEADER 00000caa a2200000 c 4500
001 1890729051
003 DE-627
005 20250730164344.0
007 cr uuu---uuuuu
008 240605s2023 xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/ad0902  |2 doi 
035 |a (DE-627)1890729051 
035 |a (DE-599)KXP1890729051 
035 |a (OCoLC)1443679431 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Stengl, Christina  |d 1997-  |e VerfasserIn  |0 (DE-588)1372195602  |0 (DE-627)193157782X  |4 aut 
245 1 2 |a A phantom to simulate organ motion and its effect on dose distribution in carbon ion therapy for pancreatic cancer  |c Christina Stengl, Kathrin Panow, Eric Arbes, Iván D. Muñoz, Jeppe B. Christensen, Christian Neelsen, Fabian Dinkel, Artur Weidner, Armin Runz, Wibke Johnen, Jakob Liermann, Gernot Echner, José Vedelago, Oliver Jäkel 
264 1 |c 11 December 2023 
300 |a 15 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 05.06.2024 
520 |a Objective. Carbon ion radiotherapy is a promising radiation technique for malignancies like pancreatic cancer. However, organs’ motion imposes challenges for achieving homogeneous dose delivery. In this study, an anthropomorphic Pancreas Phantom for Ion-beam Therapy (PPIeT) was developed to simulate breathing and gastrointestinal motion during radiotherapy. Approach. The developed phantom contains a pancreas, two kidneys, a duodenum, a spine and a spinal cord. The shell of the organs was 3D printed and filled with agarose-based mixtures. Hounsfield Units (HU) of PPIeTs’ organs were measured by CT. The pancreas motion amplitude in cranial-caudal (CC) direction was evaluated from patients’ 4D CT data. Motions within the obtained range were simulated and analyzed in PPIeT using MRI. Additionally, GI motion was mimicked by changing the volume of the duodenum and quantified by MRI. A patient-like treatment plan was calculated for carbon ions, and the phantom was irradiated in a static and moving condition. Dose measurements in the organs were performed using an ionization chamber and dosimetric films. Main results. PPIeT presented tissue equivalent HU and reproducible breathing-induced CC displacements of the pancreas between (3.98 ± 0.36) mm and a maximum of (18.19 ± 0.44) mm. The observed maximum change in distance of (14.28 ± 0.12) mm between pancreas and duodenum was consistent with findings in patients. Carbon ion irradiation revealed homogenous coverage of the virtual tumor at the pancreas in static condition with a 1% deviation from the treatment plan. Instead, the dose delivery during motion with the maximum amplitude yielded an underdosage of 21% at the target and an increased uncertainty by two orders of magnitude. Significance. A dedicated phantom was designed and developed for breathing motion assessment of dose deposition during carbon ion radiotherapy. PPIeT is a unique tool for dose verification in the pancreas and its organs at risk during end-to-end tests. 
700 1 |a Panow, Kathrin  |e VerfasserIn  |4 aut 
700 1 |a Arbes, Eric  |e VerfasserIn  |4 aut 
700 1 |a Muñoz, Iván Domingo  |d 1984-  |e VerfasserIn  |0 (DE-588)1300351586  |0 (DE-627)1858138191  |4 aut 
700 1 |a Christensen, Jeppe Brage  |e VerfasserIn  |0 (DE-588)1300351934  |0 (DE-627)1858138582  |4 aut 
700 1 |a Neelsen, Christian  |e VerfasserIn  |0 (DE-588)1300124385  |0 (DE-627)1857979745  |4 aut 
700 1 |a Dinkel, Fabian  |e VerfasserIn  |4 aut 
700 1 |a Weidner, Artur  |d 1990-  |e VerfasserIn  |0 (DE-588)1253804214  |0 (DE-627)1796131563  |4 aut 
700 1 |a Runz, Armin  |e VerfasserIn  |0 (DE-588)116699953X  |0 (DE-627)1030846480  |0 (DE-576)510993516  |4 aut 
700 1 |a Johnen, Wibke  |e VerfasserIn  |0 (DE-588)1166999270  |0 (DE-627)1030846324  |0 (DE-576)510993192  |4 aut 
700 1 |a Liermann, Jakob  |d 1989-  |e VerfasserIn  |0 (DE-588)1147779287  |0 (DE-627)1007181842  |0 (DE-576)496034170  |4 aut 
700 1 |a Echner, Gernot  |e VerfasserIn  |0 (DE-588)1197152849  |0 (DE-627)1678952621  |4 aut 
700 1 |a Vedelago, José  |e VerfasserIn  |0 (DE-588)1251835139  |0 (DE-627)1789602149  |4 aut 
700 1 |a Jäkel, Oliver  |d 1964-  |e VerfasserIn  |0 (DE-588)1050056302  |0 (DE-627)783260709  |0 (DE-576)404358705  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 68(2023), 24, Artikel-ID 245013, Seite 1-15  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a A phantom to simulate organ motion and its effect on dose distribution in carbon ion therapy for pancreatic cancer 
773 1 8 |g volume:68  |g year:2023  |g number:24  |g elocationid:245013  |g pages:1-15  |g extent:15  |a A phantom to simulate organ motion and its effect on dose distribution in carbon ion therapy for pancreatic cancer 
856 4 0 |u https://doi.org/10.1088/1361-6560/ad0902  |x Resolving-System  |x Verlag  |z kostenfrei  |3 Volltext 
856 4 0 |u https://dx.doi.org/10.1088/1361-6560/ad0902  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20240605 
993 |a Article 
994 |a 2023 
998 |g 1050056302  |a Jäkel, Oliver  |m 1050056302:Jäkel, Oliver  |d 50000  |e 50000PJ1050056302  |k 0/50000/  |p 14  |y j 
998 |g 1251835139  |a Vedelago, José  |m 1251835139:Vedelago, José  |d 910000  |d 911400  |e 910000PV1251835139  |e 911400PV1251835139  |k 0/910000/  |k 1/910000/911400/  |p 13 
998 |g 1197152849  |a Echner, Gernot  |m 1197152849:Echner, Gernot  |p 12 
998 |g 1147779287  |a Liermann, Jakob  |m 1147779287:Liermann, Jakob  |d 910000  |d 911400  |e 910000PL1147779287  |e 911400PL1147779287  |k 0/910000/  |k 1/910000/911400/  |p 11 
998 |g 1166999270  |a Johnen, Wibke  |m 1166999270:Johnen, Wibke  |p 10 
998 |g 116699953X  |a Runz, Armin  |m 116699953X:Runz, Armin  |p 9 
998 |g 1253804214  |a Weidner, Artur  |m 1253804214:Weidner, Artur  |d 50000  |e 50000PW1253804214  |k 0/50000/  |p 8 
998 |g 1300124385  |a Neelsen, Christian  |m 1300124385:Neelsen, Christian  |p 6 
998 |g 1300351934  |a Christensen, Jeppe Brage  |m 1300351934:Christensen, Jeppe Brage  |p 5 
998 |g 1300351586  |a Muñoz, Iván Domingo  |m 1300351586:Muñoz, Iván Domingo  |d 130000  |e 130000PM1300351586  |k 0/130000/  |p 4 
998 |g 1372195602  |a Stengl, Christina  |m 1372195602:Stengl, Christina  |d 50000  |e 50000PS1372195602  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1890729051  |e 4534803559 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"15 S."}],"title":[{"title_sort":"phantom to simulate organ motion and its effect on dose distribution in carbon ion therapy for pancreatic cancer","title":"A phantom to simulate organ motion and its effect on dose distribution in carbon ion therapy for pancreatic cancer"}],"relHost":[{"disp":"A phantom to simulate organ motion and its effect on dose distribution in carbon ion therapy for pancreatic cancerPhysics in medicine and biology","origin":[{"dateIssuedDisp":"1956-","dateIssuedKey":"1956","publisherPlace":"Bristol","publisher":"IOP Publ."}],"id":{"issn":["1361-6560"],"zdb":["1473501-5"],"eki":["269016163"]},"recId":"269016163","type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["1.1956 -"],"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"language":["eng"],"part":{"pages":"1-15","year":"2023","issue":"24","extent":"15","text":"68(2023), 24, Artikel-ID 245013, Seite 1-15","volume":"68"},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Physics in medicine and biology","title_sort":"Physics in medicine and biology","subtitle":"an official journal of the Institute of Physics and Engineering in Medicine"}]}],"name":{"displayForm":["Christina Stengl, Kathrin Panow, Eric Arbes, Iván D. Muñoz, Jeppe B. Christensen, Christian Neelsen, Fabian Dinkel, Artur Weidner, Armin Runz, Wibke Johnen, Jakob Liermann, Gernot Echner, José Vedelago, Oliver Jäkel"]},"origin":[{"dateIssuedDisp":"11 December 2023","dateIssuedKey":"2023"}],"recId":"1890729051","id":{"eki":["1890729051"],"doi":["10.1088/1361-6560/ad0902"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"display":"Stengl, Christina","family":"Stengl","role":"aut","given":"Christina"},{"display":"Panow, Kathrin","family":"Panow","role":"aut","given":"Kathrin"},{"family":"Arbes","role":"aut","display":"Arbes, Eric","given":"Eric"},{"given":"Iván Domingo","display":"Muñoz, Iván Domingo","role":"aut","family":"Muñoz"},{"given":"Jeppe Brage","display":"Christensen, Jeppe Brage","family":"Christensen","role":"aut"},{"given":"Christian","role":"aut","family":"Neelsen","display":"Neelsen, Christian"},{"family":"Dinkel","role":"aut","display":"Dinkel, Fabian","given":"Fabian"},{"family":"Weidner","role":"aut","display":"Weidner, Artur","given":"Artur"},{"given":"Armin","family":"Runz","role":"aut","display":"Runz, Armin"},{"given":"Wibke","display":"Johnen, Wibke","role":"aut","family":"Johnen"},{"role":"aut","family":"Liermann","display":"Liermann, Jakob","given":"Jakob"},{"given":"Gernot","display":"Echner, Gernot","role":"aut","family":"Echner"},{"family":"Vedelago","role":"aut","display":"Vedelago, José","given":"José"},{"role":"aut","family":"Jäkel","display":"Jäkel, Oliver","given":"Oliver"}],"note":["Gesehen am 05.06.2024"],"language":["eng"]} 
SRT |a STENGLCHRIPHANTOMTOS1120