Evaluation of a cycle-generative adversarial network-based cone-beam CT to synthetic CT conversion algorithm for adaptive radiation therapy

Purpose - Image-guided radiation therapy could benefit from implementing adaptive radiation therapy (ART) techniques. A cycle-generative adversarial network (cycle-GAN)-based cone-beam computed tomography (CBCT)-to-synthetic CT (sCT) conversion algorithm was evaluated regarding image quality, image...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Eckl, Miriam (VerfasserIn) , Hoppen, Lea (VerfasserIn) , Sarria, Gustavo R. (VerfasserIn) , Boda-Heggemann, Judit (VerfasserIn) , Simeonova-Chergou, Anna (VerfasserIn) , Steil, Volker (VerfasserIn) , Giordano, Frank Anton (VerfasserIn) , Fleckenstein, Jens (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 24 November 2020
In: Physica medica
Year: 2020, Jahrgang: 80, Pages: 308-316
ISSN:1724-191X
DOI:10.1016/j.ejmp.2020.11.007
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.ejmp.2020.11.007
Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S1120179720302817
Volltext
Verfasserangaben:Miriam Eckl, Lea Hoppen, Gustavo R. Sarria, Judit Boda-Heggemann, Anna Simeonova-Chergou, Volker Steil, Frank A. Giordano, Jens Fleckenstein

MARC

LEADER 00000caa a2200000 c 4500
001 1895437024
003 DE-627
005 20241205151754.0
007 cr uuu---uuuuu
008 240715s2020 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejmp.2020.11.007  |2 doi 
035 |a (DE-627)1895437024 
035 |a (DE-599)KXP1895437024 
035 |a (OCoLC)1475302496 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Eckl, Miriam  |d 1992-  |e VerfasserIn  |0 (DE-588)1162098538  |0 (DE-627)1025541596  |0 (DE-576)507186419  |4 aut 
245 1 0 |a Evaluation of a cycle-generative adversarial network-based cone-beam CT to synthetic CT conversion algorithm for adaptive radiation therapy  |c Miriam Eckl, Lea Hoppen, Gustavo R. Sarria, Judit Boda-Heggemann, Anna Simeonova-Chergou, Volker Steil, Frank A. Giordano, Jens Fleckenstein 
264 1 |c 24 November 2020 
300 |b Illustrationen 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 15.07.2024 
520 |a Purpose - Image-guided radiation therapy could benefit from implementing adaptive radiation therapy (ART) techniques. A cycle-generative adversarial network (cycle-GAN)-based cone-beam computed tomography (CBCT)-to-synthetic CT (sCT) conversion algorithm was evaluated regarding image quality, image segmentation and dosimetric accuracy for head and neck (H&N), thoracic and pelvic body regions. - Methods - Using a cycle-GAN, three body site-specific models were priorly trained with independent paired CT and CBCT datasets of a kV imaging system (XVI, Elekta). sCT were generated based on first-fraction CBCT for 15 patients of each body region. Mean errors (ME) and mean absolute errors (MAE) were analyzed for the sCT. On the sCT, manually delineated structures were compared to deformed structures from the planning CT (pCT) and evaluated with standard segmentation metrics. Treatment plans were recalculated on sCT. A comparison of clinically relevant dose-volume parameters (D98, D50 and D2 of the target volume) and 3D-gamma (3%/3mm) analysis were performed. - Results - The mean ME and MAE were 1.4, 29.6, 5.4 Hounsfield units (HU) and 77.2, 94.2, 41.8 HU for H&N, thoracic and pelvic region, respectively. Dice similarity coefficients varied between 66.7 ± 8.3% (seminal vesicles) and 94.9 ± 2.0% (lungs). Maximum mean surface distances were 6.3 mm (heart), followed by 3.5 mm (brainstem). The mean dosimetric differences of the target volumes did not exceed 1.7%. Mean 3D gamma pass rates greater than 97.8% were achieved in all cases. - Conclusions - The presented method generates sCT images with a quality close to pCT and yielded clinically acceptable dosimetric deviations. Thus, an important prerequisite towards clinical implementation of CBCT-based ART is fulfilled. 
650 4 |a Adaptive radiation therapy 
650 4 |a Cone-beam CT 
650 4 |a Cycle-generative adversarial network-based image correction 
650 4 |a Synthetic CT 
700 1 |a Hoppen, Lea  |d 1990-  |e VerfasserIn  |0 (DE-588)1321125313  |0 (DE-627)1881258432  |4 aut 
700 1 |a Sarria, Gustavo R.  |e VerfasserIn  |0 (DE-588)1272014541  |0 (DE-627)1820779203  |4 aut 
700 1 |a Boda-Heggemann, Judit  |d 1977-  |e VerfasserIn  |0 (DE-588)1029853436  |0 (DE-627)734363087  |0 (DE-576)377699411  |4 aut 
700 1 |a Simeonova-Chergou, Anna  |d 1980-  |e VerfasserIn  |0 (DE-588)1022879944  |0 (DE-627)71732477X  |0 (DE-576)363041532  |4 aut 
700 1 |a Steil, Volker  |d 1957-  |e VerfasserIn  |0 (DE-588)1048197352  |0 (DE-627)779967224  |0 (DE-576)402012747  |4 aut 
700 1 |a Giordano, Frank Anton  |d 1980-  |e VerfasserIn  |0 (DE-588)136378455  |0 (DE-627)694333093  |0 (DE-576)300990529  |4 aut 
700 1 |a Fleckenstein, Jens  |d 1981-  |e VerfasserIn  |0 (DE-588)102911918X  |0 (DE-627)732477212  |0 (DE-576)376584599  |4 aut 
773 0 8 |i Enthalten in  |t Physica medica  |d Amsterdam : Elsevier, 1996  |g 80(2020) vom: Dez., Seite 308-316  |h Online-Ressource  |w (DE-627)364471417  |w (DE-600)2110535-2  |w (DE-576)272350176  |x 1724-191X  |7 nnas  |a Evaluation of a cycle-generative adversarial network-based cone-beam CT to synthetic CT conversion algorithm for adaptive radiation therapy 
773 1 8 |g volume:80  |g year:2020  |g month:12  |g pages:308-316  |g extent:9  |a Evaluation of a cycle-generative adversarial network-based cone-beam CT to synthetic CT conversion algorithm for adaptive radiation therapy 
856 4 0 |u https://doi.org/10.1016/j.ejmp.2020.11.007  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1120179720302817  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20240715 
993 |a Article 
994 |a 2020 
998 |g 102911918X  |a Fleckenstein, Jens  |m 102911918X:Fleckenstein, Jens  |d 60000  |e 60000PF102911918X  |k 0/60000/  |p 8  |y j 
998 |g 136378455  |a Giordano, Frank Anton  |m 136378455:Giordano, Frank Anton  |d 60000  |e 60000PG136378455  |k 0/60000/  |p 7 
998 |g 1048197352  |a Steil, Volker  |m 1048197352:Steil, Volker  |d 60000  |e 60000PS1048197352  |k 0/60000/  |p 6 
998 |g 1022879944  |a Simeonova-Chergou, Anna  |m 1022879944:Simeonova-Chergou, Anna  |d 60000  |e 60000PS1022879944  |k 0/60000/  |p 5 
998 |g 1029853436  |a Boda-Heggemann, Judit  |m 1029853436:Boda-Heggemann, Judit  |d 60000  |d 63000  |e 60000PB1029853436  |e 63000PB1029853436  |k 0/60000/  |k 1/60000/63000/  |p 4 
998 |g 1272014541  |a Sarria, Gustavo R.  |m 1272014541:Sarria, Gustavo R.  |d 60000  |d 63000  |e 60000PS1272014541  |e 63000PS1272014541  |k 0/60000/  |k 1/60000/63000/  |p 3 
998 |g 1321125313  |a Hoppen, Lea  |m 1321125313:Hoppen, Lea  |d 60000  |e 60000PH1321125313  |k 0/60000/  |p 2 
998 |g 1162098538  |a Eckl, Miriam  |m 1162098538:Eckl, Miriam  |d 60000  |e 60000PE1162098538  |k 0/60000/  |p 1  |x j 
999 |a KXP-PPN1895437024  |e 4551137936 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"role":"aut","given":"Miriam","family":"Eckl","display":"Eckl, Miriam"},{"display":"Hoppen, Lea","family":"Hoppen","role":"aut","given":"Lea"},{"display":"Sarria, Gustavo R.","family":"Sarria","given":"Gustavo R.","role":"aut"},{"given":"Judit","role":"aut","display":"Boda-Heggemann, Judit","family":"Boda-Heggemann"},{"display":"Simeonova-Chergou, Anna","family":"Simeonova-Chergou","given":"Anna","role":"aut"},{"given":"Volker","role":"aut","family":"Steil","display":"Steil, Volker"},{"display":"Giordano, Frank Anton","family":"Giordano","given":"Frank Anton","role":"aut"},{"display":"Fleckenstein, Jens","family":"Fleckenstein","role":"aut","given":"Jens"}],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"2020","dateIssuedDisp":"24 November 2020"}],"note":["Gesehen am 15.07.2024"],"title":[{"title":"Evaluation of a cycle-generative adversarial network-based cone-beam CT to synthetic CT conversion algorithm for adaptive radiation therapy","title_sort":"Evaluation of a cycle-generative adversarial network-based cone-beam CT to synthetic CT conversion algorithm for adaptive radiation therapy"}],"id":{"eki":["1895437024"],"doi":["10.1016/j.ejmp.2020.11.007"]},"name":{"displayForm":["Miriam Eckl, Lea Hoppen, Gustavo R. Sarria, Judit Boda-Heggemann, Anna Simeonova-Chergou, Volker Steil, Frank A. Giordano, Jens Fleckenstein"]},"physDesc":[{"noteIll":"Illustrationen","extent":"9 S."}],"relHost":[{"part":{"pages":"308-316","year":"2020","extent":"9","text":"80(2020) vom: Dez., Seite 308-316","volume":"80"},"language":["eng"],"id":{"zdb":["2110535-2"],"issn":["1724-191X"],"eki":["364471417"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"364471417","type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Evaluation of a cycle-generative adversarial network-based cone-beam CT to synthetic CT conversion algorithm for adaptive radiation therapyPhysica medica","title":[{"subtitle":"European journal of medical physics ; an international journal devoted to the applications of physics to medicine and biology","title_sort":"Physica medica","title":"Physica medica"}],"origin":[{"publisher":"Elsevier ; Istituti Editoriali e Poligrafici Internazionali","dateIssuedKey":"1996","dateIssuedDisp":"1996-","publisherPlace":"Amsterdam ; Pisa"}],"note":["Fortsetzung der Druck-Ausgabe","Gesehen am 12.11.2021"],"pubHistory":["Nachgewiesen 12.1996 -"]}],"recId":"1895437024"} 
SRT |a ECKLMIRIAMEVALUATION2420