In vitro testing of a funnel-tip catheter with different clot types to decrease clot migration in mechanical thrombectomy

Background - Mechanical thrombectomy is the standard treatment for acute ischemic stroke in patients with large vessel occlusion and can be performed up to 24h after symptom onset. Despite high recanalization rates, embolism in new territories has been reported in 8.6% of the cases. Causes for this...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Payne, Emily Sarah (VerfasserIn) , Krost-Reuhl, Samantha (VerfasserIn) , Heimann, Axel (VerfasserIn) , Keric, Naureen (VerfasserIn) , Masomi-Bornwasser, Julia (VerfasserIn) , Gerber, Tiemo (VerfasserIn) , Seidman, Larissa (VerfasserIn) , Kirschner, Stefanie (VerfasserIn) , Brockmann, Marc Alexander (VerfasserIn) , Tanyildizi, Yasemin (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: Dec 2023
In: Interventional neuroradiology
Year: 2023, Jahrgang: 29, Heft: 6, Pages: 637-647
ISSN:2385-2011
DOI:10.1177/15910199221122843
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1177/15910199221122843
Verlag, lizenzpflichtig, Volltext: https://journals.sagepub.com/doi/10.1177/15910199221122843
Volltext
Verfasserangaben:Emily S. Payne, Samantha Krost-Reuhl, Axel Heimann, Naureen Keric, Julia Masomi-Bornwasser, Tiemo Gerber, Larissa Seidman, Stefanie Kirschner, Marc A. Brockmann and Yasemin Tanyildizi

MARC

LEADER 00000caa a2200000 c 4500
001 1895492483
003 DE-627
005 20250118002145.0
007 cr uuu---uuuuu
008 240716s2023 xx |||||o 00| ||eng c
024 7 |a 10.1177/15910199221122843  |2 doi 
035 |a (DE-627)1895492483 
035 |a (DE-599)KXP1895492483 
035 |a (OCoLC)1475302714 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Payne, Emily Sarah  |d 1996-  |e VerfasserIn  |0 (DE-588)1251767559  |0 (DE-627)1789514878  |4 aut 
245 1 0 |a In vitro testing of a funnel-tip catheter with different clot types to decrease clot migration in mechanical thrombectomy  |c Emily S. Payne, Samantha Krost-Reuhl, Axel Heimann, Naureen Keric, Julia Masomi-Bornwasser, Tiemo Gerber, Larissa Seidman, Stefanie Kirschner, Marc A. Brockmann and Yasemin Tanyildizi 
264 1 |c Dec 2023 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Erstmals online veröffentlicht: 1. September 2022 
500 |a Gesehen am 16.07.2024 
520 |a Background - Mechanical thrombectomy is the standard treatment for acute ischemic stroke in patients with large vessel occlusion and can be performed up to 24h after symptom onset. Despite high recanalization rates, embolism in new territories has been reported in 8.6% of the cases. Causes for this could be clot abruption during stent retrieval into the smaller opening of a standard distal access catheter, and antegrade blood flow via collaterals despite proximal balloon protection. A funnel-shaped tip with a larger internal diameter was developed to increase the rate of first-pass recanalization and to improve the safety and efficacy of mechanical thrombectomy. - Methods - This in vitro study compared the efficacy of a funnel-shaped tip with a standard tip in combination with different clot compositions. Mechanical thrombectomy was performed 80 times for each tip, using two stent retrievers (Trevo XP ProVue 3/20 mm, 4/20 mm) and four different clot types (hard vs. soft clots, 0-24h vs. 72h aged clots). - Results - Significantly higher first-pass recanalization rates (mTICI 3) were observed for the funnel-shaped tip, 70.0% versus 30.0% for the standard tip (absolute difference, 32; relative difference 57.1%; P < .001), regardless of the clot type and stent retriever. Recanalization could be increased using harder Chandler loop clots versus softer statically generated clots, as well as 0-24h versus 72h aged clots, respectively. - Conclusion - The funnel-shaped tip achieved higher first-pass recanalization rates than the smaller standard tip and lower rates of clot abruption at the tip. Clot compositions and aging times impacted recanalization rates. 
700 1 |a Krost-Reuhl, Samantha  |e VerfasserIn  |4 aut 
700 1 |a Heimann, Axel  |e VerfasserIn  |4 aut 
700 1 |a Keric, Naureen  |e VerfasserIn  |4 aut 
700 1 |a Masomi-Bornwasser, Julia  |e VerfasserIn  |4 aut 
700 1 |a Gerber, Tiemo  |e VerfasserIn  |4 aut 
700 1 |a Seidman, Larissa  |e VerfasserIn  |4 aut 
700 1 |a Kirschner, Stefanie  |d 1980-  |e VerfasserIn  |0 (DE-588)1075006708  |0 (DE-627)832847429  |0 (DE-576)443195234  |4 aut 
700 1 |8 1\p  |a Brockmann, Marc Alexander  |d 1974-  |e VerfasserIn  |0 (DE-588)128367334  |0 (DE-627)706967704  |0 (DE-576)297104489  |4 aut 
700 1 |a Tanyildizi, Yasemin  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Interventional neuroradiology  |d London : Sage Publishing, 1995  |g 29(2023), 6 vom: Dez., Seite 637-647  |h Online-Ressource  |w (DE-627)634383299  |w (DE-600)2571161-1  |w (DE-576)351479112  |x 2385-2011  |7 nnas  |a In vitro testing of a funnel-tip catheter with different clot types to decrease clot migration in mechanical thrombectomy 
773 1 8 |g volume:29  |g year:2023  |g number:6  |g month:12  |g pages:637-647  |g extent:11  |a In vitro testing of a funnel-tip catheter with different clot types to decrease clot migration in mechanical thrombectomy 
856 4 0 |u https://doi.org/10.1177/15910199221122843  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.sagepub.com/doi/10.1177/15910199221122843  |x Verlag  |z lizenzpflichtig  |3 Volltext 
883 |8 1\p  |a cgwrk  |d 20241001  |q DE-101  |u https://d-nb.info/provenance/plan#cgwrk 
951 |a AR 
992 |a 20240716 
993 |a Article 
994 |a 2023 
998 |g 1075006708  |a Kirschner, Stefanie  |m 1075006708:Kirschner, Stefanie  |d 60000  |d 60200  |d 60210  |e 60000PK1075006708  |e 60200PK1075006708  |e 60210PK1075006708  |k 0/60000/  |k 1/60000/60200/  |k 2/60000/60200/60210/  |p 8 
999 |a KXP-PPN1895492483  |e 4551535877 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"recId":"1895492483","note":["Erstmals online veröffentlicht: 1. September 2022","Gesehen am 16.07.2024"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"family":"Payne","given":"Emily Sarah","roleDisplay":"VerfasserIn","display":"Payne, Emily Sarah","role":"aut"},{"family":"Krost-Reuhl","given":"Samantha","roleDisplay":"VerfasserIn","display":"Krost-Reuhl, Samantha","role":"aut"},{"roleDisplay":"VerfasserIn","display":"Heimann, Axel","role":"aut","family":"Heimann","given":"Axel"},{"role":"aut","display":"Keric, Naureen","roleDisplay":"VerfasserIn","given":"Naureen","family":"Keric"},{"given":"Julia","family":"Masomi-Bornwasser","role":"aut","roleDisplay":"VerfasserIn","display":"Masomi-Bornwasser, Julia"},{"family":"Gerber","given":"Tiemo","roleDisplay":"VerfasserIn","display":"Gerber, Tiemo","role":"aut"},{"family":"Seidman","given":"Larissa","display":"Seidman, Larissa","roleDisplay":"VerfasserIn","role":"aut"},{"given":"Stefanie","family":"Kirschner","role":"aut","roleDisplay":"VerfasserIn","display":"Kirschner, Stefanie"},{"given":"Marc Alexander","family":"Brockmann","role":"aut","roleDisplay":"VerfasserIn","display":"Brockmann, Marc Alexander"},{"roleDisplay":"VerfasserIn","display":"Tanyildizi, Yasemin","role":"aut","family":"Tanyildizi","given":"Yasemin"}],"title":[{"title":"In vitro testing of a funnel-tip catheter with different clot types to decrease clot migration in mechanical thrombectomy","title_sort":"In vitro testing of a funnel-tip catheter with different clot types to decrease clot migration in mechanical thrombectomy"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisherPlace":"London ; Milano","publisher":"Sage Publishing ; Ed. del Centauro","dateIssuedKey":"1995","dateIssuedDisp":"1995-"}],"id":{"issn":["2385-2011"],"zdb":["2571161-1"],"eki":["634383299"]},"pubHistory":["1.1995 -"],"part":{"year":"2023","issue":"6","pages":"637-647","text":"29(2023), 6 vom: Dez., Seite 637-647","volume":"29","extent":"11"},"titleAlt":[{"title":"INR"}],"note":["Gesehen am 20.01.2017"],"disp":"In vitro testing of a funnel-tip catheter with different clot types to decrease clot migration in mechanical thrombectomyInterventional neuroradiology","type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"recId":"634383299","title":[{"title_sort":"Interventional neuroradiology","title":"Interventional neuroradiology","subtitle":"INR : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences"}]}],"physDesc":[{"extent":"11 S."}],"name":{"displayForm":["Emily S. Payne, Samantha Krost-Reuhl, Axel Heimann, Naureen Keric, Julia Masomi-Bornwasser, Tiemo Gerber, Larissa Seidman, Stefanie Kirschner, Marc A. Brockmann and Yasemin Tanyildizi"]},"id":{"eki":["1895492483"],"doi":["10.1177/15910199221122843"]},"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"Dec 2023"}]} 
SRT |a PAYNEEMILYINVITROTES2023