Central and peripheral circulation differ during off-pump coronary artery bypass grafting

Background: Off-pump coronary artery bypass grafting (OPCAB) is an alternative to on-pump coronary artery bypass grafting (CABG) with cardiopulmonary bypass (CPB). During OPCAB, the temporary use of an intracoronary shunt and inotropic medication or catecholamines should keep the central hemodynamic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Saemann, Lars (VerfasserIn) , Zubarevich, Alina (VerfasserIn) , Wenzel, Folker (VerfasserIn) , Soethoff, Jasmin (VerfasserIn) , Korkmaz-İçöz, Sevil (VerfasserIn) , Hoorn, Fabio (VerfasserIn) , Karck, Matthias (VerfasserIn) , Simm, Andreas (VerfasserIn) , Szabó, Gábor (VerfasserIn) , Veres, Gábor (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 16 January 2024
In: Reviews in cardiovascular medicine
Year: 2024, Jahrgang: 25, Heft: 1, Pages: 1-6
ISSN:2153-8174
DOI:10.31083/j.rcm2501030
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.31083/j.rcm2501030
Verlag, kostenfrei, Volltext: https://www.imrpress.com/journal/RCM/25/1/10.31083/j.rcm2501030
Volltext
Verfasserangaben:Lars Saemann, Alina Zubarevich, Folker Wenzel, Jasmin Soethoff, Sevil Korkmaz-Icöz, Fabio Hoorn, Matthias Karck, Andreas Simm, Gábor Szabó, Gábor Veres

MARC

LEADER 00000caa a2200000 c 4500
001 1896605060
003 DE-627
005 20241205154559.0
007 cr uuu---uuuuu
008 240726s2024 xx |||||o 00| ||eng c
024 7 |a 10.31083/j.rcm2501030  |2 doi 
035 |a (DE-627)1896605060 
035 |a (DE-599)KXP1896605060 
035 |a (OCoLC)1475304621 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Saemann, Lars  |d 1994-  |e VerfasserIn  |0 (DE-588)1203655118  |0 (DE-627)1688668497  |4 aut 
245 1 0 |a Central and peripheral circulation differ during off-pump coronary artery bypass grafting  |c Lars Saemann, Alina Zubarevich, Folker Wenzel, Jasmin Soethoff, Sevil Korkmaz-Icöz, Fabio Hoorn, Matthias Karck, Andreas Simm, Gábor Szabó, Gábor Veres 
264 1 |c 16 January 2024 
300 |b Illustrationen 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 26.07.2024 
520 |a Background: Off-pump coronary artery bypass grafting (OPCAB) is an alternative to on-pump coronary artery bypass grafting (CABG) with cardiopulmonary bypass (CPB). During OPCAB, the temporary use of an intracoronary shunt and inotropic medication or catecholamines should keep the central hemodynamics constant. Nevertheless, the need for conversion to on-pump CABG often occurs unexpectedly, most likely due to circulation instability. Circulation instability can appear first in peripheral body parts; therefore, peripheral microcirculation might serve as a predictor for the upcoming conversion to on-pump CABG. We investigated the impact of coronary artery ligation and shunt insertion during OPCAB on cutaneous microcirculation (cLDP) with Laser Doppler Perfusion Technology and transcutaneous oxygen partial pressure (tcpO2). Methods: In a pig model of OPCAB, peripheral circulation was evaluated after cLDP (N = 17) and tcpO2 (N = 6) monitoring. Systolic, diastolic, and mean arterial pressure were also observed to prove the independence of perfusion measurement results from hemodynamic parameters. Results: Ligation time during cLDP and tcpO2 monitoring were 101 ± 49 s and 83 ± 33 s, respectively. Shunt time was 11 ± 3 min during cLDP and 13 ± 2 min during tcpO2 measurement. Ligation of the left anterior descending coronary artery (LAD) reduced cLDP significantly to 88 ± 14% (p = 0.007) and tcpO2 to 71 ± 25% (p = 0.038). Inserting a temporary shunt into the LAD significantly improved cLDP (p = 0.006) and tcpO2 (p = 0.015) compared to ligation. cLDP was restored to 99%, and tcpO2 was restored to 91% of the baseline level before ligation. All hemodynamic parameters remained stable and did not change significantly during OPCAB. Conclusions: Although hemodynamic parameters stayed constant, peripheral microcirculation was influenced markedly during OPCAB. Inserting a temporary shut into the LAD leads to a complete normalization of peripheral microcirculation, regarding evaluation by cLDP and tcpO2. 
700 1 |a Zubarevich, Alina  |d 1986-  |e VerfasserIn  |0 (DE-588)118859303X  |0 (DE-627)1667542192  |4 aut 
700 1 |a Wenzel, Folker  |d 1970-  |e VerfasserIn  |0 (DE-588)120100584  |0 (DE-627)08044671X  |0 (DE-576)292041837  |4 aut 
700 1 |a Soethoff, Jasmin  |d 1992-  |e VerfasserIn  |0 (DE-588)123766506X  |0 (DE-627)1764593464  |4 aut 
700 1 |a Korkmaz-İçöz, Sevil  |e VerfasserIn  |0 (DE-588)1062748697  |0 (DE-627)806830336  |0 (DE-576)420147845  |4 aut 
700 1 |a Hoorn, Fabio  |e VerfasserIn  |0 (DE-588)130810393X  |0 (DE-627)186887754X  |4 aut 
700 1 |a Karck, Matthias  |d 1961-  |e VerfasserIn  |0 (DE-588)130833525  |0 (DE-627)505909340  |0 (DE-576)298366169  |4 aut 
700 1 |a Simm, Andreas  |e VerfasserIn  |4 aut 
700 1 |a Szabó, Gábor  |d 1969-  |e VerfasserIn  |0 (DE-588)1022955152  |0 (DE-627)717338681  |0 (DE-576)366215485  |4 aut 
700 1 |a Veres, Gábor  |e VerfasserIn  |0 (DE-588)1080537139  |0 (DE-627)844782319  |0 (DE-576)453604927  |4 aut 
773 0 8 |i Enthalten in  |t Reviews in cardiovascular medicine  |d New York, NY : MedReview LLC, 2000  |g 25(2024), 1, Artikel-ID 30, Seite 1-6  |h Online-Ressource  |w (DE-627)363773541  |w (DE-600)2108911-5  |w (DE-576)475542460  |x 2153-8174  |7 nnas  |a Central and peripheral circulation differ during off-pump coronary artery bypass grafting 
773 1 8 |g volume:25  |g year:2024  |g number:1  |g elocationid:30  |g pages:1-6  |g extent:6  |a Central and peripheral circulation differ during off-pump coronary artery bypass grafting 
856 4 0 |u https://doi.org/10.31083/j.rcm2501030  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.imrpress.com/journal/RCM/25/1/10.31083/j.rcm2501030  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20240726 
993 |a Article 
994 |a 2024 
998 |g 1080537139  |a Veres, Gábor  |m 1080537139:Veres, Gábor  |d 50000  |e 50000PV1080537139  |k 0/50000/  |p 10  |y j 
998 |g 1022955152  |a Szabó, Gábor  |m 1022955152:Szabó, Gábor  |d 910000  |d 910200  |d 50000  |e 910000PS1022955152  |e 910200PS1022955152  |e 50000PS1022955152  |k 0/910000/  |k 1/910000/910200/  |k 0/50000/  |p 9 
998 |g 130833525  |a Karck, Matthias  |m 130833525:Karck, Matthias  |d 910000  |d 910200  |e 910000PK130833525  |e 910200PK130833525  |k 0/910000/  |k 1/910000/910200/  |p 7 
998 |g 1062748697  |a Korkmaz-İçöz, Sevil  |m 1062748697:Korkmaz-İçöz, Sevil  |d 910000  |d 910200  |e 910000PK1062748697  |e 910200PK1062748697  |k 0/910000/  |k 1/910000/910200/  |p 5 
999 |a KXP-PPN1896605060  |e 4557322875 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 26.07.2024"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title_sort":"Central and peripheral circulation differ during off-pump coronary artery bypass grafting","title":"Central and peripheral circulation differ during off-pump coronary artery bypass grafting"}],"relHost":[{"titleAlt":[{"title":"Cardiovascular medicine"}],"pubHistory":["1.2000 -"],"id":{"zdb":["2108911-5"],"eki":["363773541"],"issn":["2153-8174"]},"part":{"volume":"25","year":"2024","text":"25(2024), 1, Artikel-ID 30, Seite 1-6","extent":"6","issue":"1","pages":"1-6"},"origin":[{"publisher":"MedReview LLC ; MedReview LLC","dateIssuedDisp":"2000-","dateIssuedKey":"2000","publisherPlace":"New York, NY ; Mercer Island, WA"}],"title":[{"title_sort":"Reviews in cardiovascular medicine","title":"Reviews in cardiovascular medicine"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 26.04.22"],"recId":"363773541","physDesc":[{"extent":"Online-Ressource"}],"disp":"Central and peripheral circulation differ during off-pump coronary artery bypass graftingReviews in cardiovascular medicine"}],"person":[{"family":"Saemann","given":"Lars","role":"aut","display":"Saemann, Lars"},{"display":"Zubarevich, Alina","family":"Zubarevich","role":"aut","given":"Alina"},{"family":"Wenzel","given":"Folker","role":"aut","display":"Wenzel, Folker"},{"display":"Soethoff, Jasmin","family":"Soethoff","given":"Jasmin","role":"aut"},{"given":"Sevil","role":"aut","family":"Korkmaz-İçöz","display":"Korkmaz-İçöz, Sevil"},{"given":"Fabio","role":"aut","family":"Hoorn","display":"Hoorn, Fabio"},{"display":"Karck, Matthias","family":"Karck","role":"aut","given":"Matthias"},{"display":"Simm, Andreas","given":"Andreas","role":"aut","family":"Simm"},{"family":"Szabó","given":"Gábor","role":"aut","display":"Szabó, Gábor"},{"display":"Veres, Gábor","family":"Veres","role":"aut","given":"Gábor"}],"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"16 January 2024"}],"physDesc":[{"noteIll":"Illustrationen","extent":"6 S."}],"recId":"1896605060","id":{"eki":["1896605060"],"doi":["10.31083/j.rcm2501030"]},"name":{"displayForm":["Lars Saemann, Alina Zubarevich, Folker Wenzel, Jasmin Soethoff, Sevil Korkmaz-Icöz, Fabio Hoorn, Matthias Karck, Andreas Simm, Gábor Szabó, Gábor Veres"]}} 
SRT |a SAEMANNLARCENTRALAND1620