Advanced diffusion-weighted imaging sequences for breast MRI: comprehensive comparison of improved sequences and ultra-high B-values to identify the optimal combination
This study investigated the image quality and choice of ultra-high b-value of two DWI breast-MRI research applications. The study cohort comprised 40 patients (20 malignant lesions). In addition to s-DWI with two m-b-values (b50 and b800) and three e-b-values (e-b1500, e-b2000, and e-b2500), z-DWI a...
Gespeichert in:
| Hauptverfasser: | , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
7 February 2023
|
| In: |
Diagnostics
Year: 2023, Jahrgang: 13, Heft: 4, Pages: 1-14 |
| ISSN: | 2075-4418 |
| DOI: | 10.3390/diagnostics13040607 |
| Online-Zugang: | Verlag, kostenfrei, Volltext: https://doi.org/10.3390/diagnostics13040607 Verlag, kostenfrei, Volltext: https://www.mdpi.com/2075-4418/13/4/607 |
| Verfasserangaben: | Daniel Hausmann, Inga Todorski, Alexandra Pindur, Elisabeth Weiland, Thomas Benkert, Lars Bosshard, Michael Prummer and Rahel A. Kubik-Huch |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1898764689 | ||
| 003 | DE-627 | ||
| 005 | 20241205163010.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 240815s2023 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.3390/diagnostics13040607 |2 doi | |
| 035 | |a (DE-627)1898764689 | ||
| 035 | |a (DE-599)KXP1898764689 | ||
| 035 | |a (OCoLC)1475307970 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Hausmann, Daniel |d 1981- |e VerfasserIn |0 (DE-588)1012080293 |0 (DE-627)660894432 |0 (DE-576)344897125 |4 aut | |
| 245 | 1 | 0 | |a Advanced diffusion-weighted imaging sequences for breast MRI |b comprehensive comparison of improved sequences and ultra-high B-values to identify the optimal combination |c Daniel Hausmann, Inga Todorski, Alexandra Pindur, Elisabeth Weiland, Thomas Benkert, Lars Bosshard, Michael Prummer and Rahel A. Kubik-Huch |
| 264 | 1 | |c 7 February 2023 | |
| 300 | |b Illustrationen | ||
| 300 | |a 14 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 15.08.2024 | ||
| 520 | |a This study investigated the image quality and choice of ultra-high b-value of two DWI breast-MRI research applications. The study cohort comprised 40 patients (20 malignant lesions). In addition to s-DWI with two m-b-values (b50 and b800) and three e-b-values (e-b1500, e-b2000, and e-b2500), z-DWI and IR m-b1500 DWI were applied. z-DWI was acquired with the same measured b-values and e-b-values as the standard sequence. For IR m-b1500 DWI, b50 and b1500 were measured, and e-b2000 and e-b2500 were mathematically extrapolated. Three readers used Likert scales to independently analyze all ultra-high b-values (b1500-b2500) for each DWI with regards to scan preference and image quality. ADC values were measured in all 20 lesions. z-DWI was the most preferred (54%), followed by IR m-b1500 DWI (46%). b1500 was significantly preferred over b2000 for z-DWI and IR m-b1500 DWI (p = 0.001 and p = 0.002, respectively). Lesion detection was not significantly different among sequences or b-values (p = 0.174). There were no significant differences in measured ADC values within lesions between s-DWI (ADC: 0.97 [±0.09] × 10−3 mm2/s) and z-DWI (ADC: 0.99 [±0.11] × 10−3 mm2/s; p = 1.000). However, there was a trend toward lower values in IR m-b1500 DWI (ADC: 0.80 [±0.06] × 10−3 mm2/s) than in s-DWI (p = 0.090) and z-DWI (p = 0.110). Overall, image quality was superior and there were fewer image artifacts when using the advanced sequences (z-DWI + IR m-b1500 DWI) compared with s-DWI. Considering scan preferences, we found that the optimal combination was z-DWI with a calculated b1500, especially regarding examination time. | ||
| 650 | 4 | |a artifacts | |
| 650 | 4 | |a breast | |
| 650 | 4 | |a breast cancer | |
| 650 | 4 | |a diffusion-weighted imaging | |
| 650 | 4 | |a image quality | |
| 650 | 4 | |a magnetic resonance imaging | |
| 650 | 4 | |a noise reduction | |
| 700 | 1 | |a Todorski, Inga |e VerfasserIn |4 aut | |
| 700 | 1 | |a Pindur, Alexandra |e VerfasserIn |4 aut | |
| 700 | 1 | |a Weiland, Elisabeth |e VerfasserIn |4 aut | |
| 700 | 1 | |a Benkert, Thomas |e VerfasserIn |4 aut | |
| 700 | 1 | |a Bosshard, Lars |e VerfasserIn |4 aut | |
| 700 | 1 | |a Prummer, Michael |e VerfasserIn |4 aut | |
| 700 | 1 | |a Kubik-Huch, Rahel A. |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Diagnostics |d Basel : MDPI, 2011 |g 13(2023), 4, Artikel-ID 607, Seite 1-14 |h Online-Ressource |w (DE-627)718627814 |w (DE-600)2662336-5 |w (DE-576)365413917 |x 2075-4418 |7 nnas |a Advanced diffusion-weighted imaging sequences for breast MRI comprehensive comparison of improved sequences and ultra-high B-values to identify the optimal combination |
| 773 | 1 | 8 | |g volume:13 |g year:2023 |g number:4 |g elocationid:607 |g pages:1-14 |g extent:14 |a Advanced diffusion-weighted imaging sequences for breast MRI comprehensive comparison of improved sequences and ultra-high B-values to identify the optimal combination |
| 856 | 4 | 0 | |u https://doi.org/10.3390/diagnostics13040607 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://www.mdpi.com/2075-4418/13/4/607 |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20240815 | ||
| 993 | |a Article | ||
| 994 | |a 2023 | ||
| 998 | |g 1012080293 |a Hausmann, Daniel |m 1012080293:Hausmann, Daniel |d 60000 |d 65200 |e 60000PH1012080293 |e 65200PH1012080293 |k 0/60000/ |k 1/60000/65200/ |p 1 |x j | ||
| 999 | |a KXP-PPN1898764689 |e 4566414531 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"title":[{"title_sort":"Advanced diffusion-weighted imaging sequences for breast MRI","subtitle":"comprehensive comparison of improved sequences and ultra-high B-values to identify the optimal combination","title":"Advanced diffusion-weighted imaging sequences for breast MRI"}],"person":[{"family":"Hausmann","given":"Daniel","display":"Hausmann, Daniel","roleDisplay":"VerfasserIn","role":"aut"},{"roleDisplay":"VerfasserIn","display":"Todorski, Inga","role":"aut","family":"Todorski","given":"Inga"},{"roleDisplay":"VerfasserIn","display":"Pindur, Alexandra","role":"aut","family":"Pindur","given":"Alexandra"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Weiland, Elisabeth","given":"Elisabeth","family":"Weiland"},{"family":"Benkert","given":"Thomas","display":"Benkert, Thomas","roleDisplay":"VerfasserIn","role":"aut"},{"roleDisplay":"VerfasserIn","display":"Bosshard, Lars","role":"aut","family":"Bosshard","given":"Lars"},{"roleDisplay":"VerfasserIn","display":"Prummer, Michael","role":"aut","family":"Prummer","given":"Michael"},{"roleDisplay":"VerfasserIn","display":"Kubik-Huch, Rahel A.","role":"aut","family":"Kubik-Huch","given":"Rahel A."}],"recId":"1898764689","language":["eng"],"note":["Gesehen am 15.08.2024"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["1898764689"],"doi":["10.3390/diagnostics13040607"]},"origin":[{"dateIssuedDisp":"7 February 2023","dateIssuedKey":"2023"}],"name":{"displayForm":["Daniel Hausmann, Inga Todorski, Alexandra Pindur, Elisabeth Weiland, Thomas Benkert, Lars Bosshard, Michael Prummer and Rahel A. Kubik-Huch"]},"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"dateIssuedDisp":"2011-","publisher":"MDPI","dateIssuedKey":"2011","publisherPlace":"Basel"}],"id":{"issn":["2075-4418"],"eki":["718627814"],"zdb":["2662336-5"]},"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 28.05.2020"],"disp":"Advanced diffusion-weighted imaging sequences for breast MRI comprehensive comparison of improved sequences and ultra-high B-values to identify the optimal combinationDiagnostics","language":["eng"],"recId":"718627814","pubHistory":["1.2011 -"],"part":{"year":"2023","issue":"4","pages":"1-14","text":"13(2023), 4, Artikel-ID 607, Seite 1-14","volume":"13","extent":"14"},"title":[{"title":"Diagnostics","subtitle":"open access journal","title_sort":"Diagnostics"}]}],"physDesc":[{"extent":"14 S.","noteIll":"Illustrationen"}]} | ||
| SRT | |a HAUSMANNDAADVANCEDDI7202 | ||