Assessment of the axial resolution of a compact gamma camera with coded aperture collimator
Purpose: Handheld gamma cameras with coded aperture collimators are under investigation for intraoperative imaging in nuclear medicine. Coded apertures are a promising collimation technique for applications such as lymph node localization due to their high sensitivity and the possibility of 3D imagi...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
21 March 2024
|
| In: |
EJNMMI Physics
Year: 2024, Jahrgang: 11, Pages: 1-21 |
| ISSN: | 2197-7364 |
| DOI: | 10.1186/s40658-024-00631-5 |
| Online-Zugang: | Verlag, kostenfrei, Volltext: https://doi.org/10.1186/s40658-024-00631-5 |
| Verfasserangaben: | Tobias Meißner, Laura Antonia Cerbone, Paolo Russo, Werner Nahm and Jürgen Hesser |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1899074023 | ||
| 003 | DE-627 | ||
| 005 | 20241205163449.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 240819s2024 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1186/s40658-024-00631-5 |2 doi | |
| 035 | |a (DE-627)1899074023 | ||
| 035 | |a (DE-599)KXP1899074023 | ||
| 035 | |a (OCoLC)1475308193 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Meißner, Tobias |e VerfasserIn |0 (DE-588)1014101379 |0 (DE-627)705167224 |0 (DE-576)348311613 |4 aut | |
| 245 | 1 | 0 | |a Assessment of the axial resolution of a compact gamma camera with coded aperture collimator |c Tobias Meißner, Laura Antonia Cerbone, Paolo Russo, Werner Nahm and Jürgen Hesser |
| 264 | 1 | |c 21 March 2024 | |
| 300 | |b Illustrationen | ||
| 300 | |a 21 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 19.08.2024 | ||
| 520 | |a Purpose: Handheld gamma cameras with coded aperture collimators are under investigation for intraoperative imaging in nuclear medicine. Coded apertures are a promising collimation technique for applications such as lymph node localization due to their high sensitivity and the possibility of 3D imaging. We evaluated the axial resolution and computational performance of two reconstruction methods. Methods: An experimental gamma camera was set up consisting of the pixelated semiconductor detector Timepix3 and MURA mask of rank 31 with round holes of 0.08 mm in diameter in a 0.11 mm thick Tungsten sheet. A set of measurements was taken where a point-like gamma source was placed centrally at 21 different positions within the range of 12–100 mm. For each source position, the detector image was reconstructed in 0.5 mm steps around the true source position, resulting in an image stack. The axial resolution was assessed by the full width at half maximum (FWHM) of the contrast-to-noise ratio (CNR) profile along the z-axis of the stack. Two reconstruction methods were compared: MURA Decoding and a 3D maximum likelihood expectation maximization algorithm (3D-MLEM). Results: While taking 4400 times longer in computation, 3D-MLEM yielded a smaller axial FWHM and a higher CNR. The axial resolution degraded from 5.3 mm and 1.8 mm at 12 mm to 42.2 mm and 13.5 mm at 100 mm for MURA Decoding and 3D-MLEM respectively. Conclusion: Our results show that the coded aperture enables the depth estimation of single point-like sources in the near field. Here, 3D-MLEM offered a better axial resolution but was computationally much slower than MURA Decoding, whose reconstruction time is compatible with real-time imaging. | ||
| 650 | 4 | |a Axial resolution | |
| 650 | 4 | |a Coded aperture | |
| 650 | 4 | |a Compact gamma camera | |
| 650 | 4 | |a Image reconstruction | |
| 650 | 4 | |a Intraoperative imaging | |
| 650 | 4 | |a Radioguided surgery | |
| 650 | 4 | |a Timepix3 | |
| 700 | 1 | |a Cerbone, Laura Antonia |e VerfasserIn |4 aut | |
| 700 | 1 | |a Russo, Paolo |e VerfasserIn |4 aut | |
| 700 | 1 | |a Nahm, Werner |e VerfasserIn |4 aut | |
| 700 | 1 | |a Hesser, Jürgen |d 1964- |e VerfasserIn |0 (DE-588)1020647353 |0 (DE-627)691291071 |0 (DE-576)361513739 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t EJNMMI Physics |d Berlin : SpringerOpen, 2014 |g 11(2024), Artikel-ID 30, Seite 1-21 |h Online-Ressource |w (DE-627)785697993 |w (DE-600)2768912-8 |w (DE-576)405822499 |x 2197-7364 |7 nnas |a Assessment of the axial resolution of a compact gamma camera with coded aperture collimator |
| 773 | 1 | 8 | |g volume:11 |g year:2024 |g elocationid:30 |g pages:1-21 |g extent:21 |a Assessment of the axial resolution of a compact gamma camera with coded aperture collimator |
| 856 | 4 | 0 | |u https://doi.org/10.1186/s40658-024-00631-5 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20240819 | ||
| 993 | |a Article | ||
| 994 | |a 2024 | ||
| 998 | |g 1020647353 |a Hesser, Jürgen |m 1020647353:Hesser, Jürgen |d 60000 |d 65200 |e 60000PH1020647353 |e 65200PH1020647353 |k 0/60000/ |k 1/60000/65200/ |p 5 |y j | ||
| 998 | |g 1014101379 |a Meißner, Tobias |m 1014101379:Meißner, Tobias |d 60000 |d 65200 |e 60000PM1014101379 |e 65200PM1014101379 |k 0/60000/ |k 1/60000/65200/ |p 1 |x j | ||
| 999 | |a KXP-PPN1899074023 |e 4567990900 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"recId":"1899074023","physDesc":[{"noteIll":"Illustrationen","extent":"21 S."}],"name":{"displayForm":["Tobias Meißner, Laura Antonia Cerbone, Paolo Russo, Werner Nahm and Jürgen Hesser"]},"id":{"doi":["10.1186/s40658-024-00631-5"],"eki":["1899074023"]},"relHost":[{"id":{"zdb":["2768912-8"],"issn":["2197-7364"],"eki":["785697993"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"785697993","pubHistory":["1.2014 -"],"part":{"year":"2024","text":"11(2024), Artikel-ID 30, Seite 1-21","pages":"1-21","extent":"21","volume":"11"},"origin":[{"dateIssuedDisp":"2014-","publisherPlace":"Berlin ; Heidelberg","dateIssuedKey":"2014","publisher":"SpringerOpen"}],"note":["Gesehen am 29.05.20"],"title":[{"title":"EJNMMI Physics","title_sort":"EJNMMI Physics"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"disp":"Assessment of the axial resolution of a compact gamma camera with coded aperture collimatorEJNMMI Physics"}],"person":[{"family":"Meißner","display":"Meißner, Tobias","given":"Tobias","role":"aut"},{"role":"aut","given":"Laura Antonia","display":"Cerbone, Laura Antonia","family":"Cerbone"},{"display":"Russo, Paolo","family":"Russo","role":"aut","given":"Paolo"},{"family":"Nahm","display":"Nahm, Werner","role":"aut","given":"Werner"},{"family":"Hesser","display":"Hesser, Jürgen","role":"aut","given":"Jürgen"}],"language":["eng"],"note":["Gesehen am 19.08.2024"],"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"21 March 2024"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title_sort":"Assessment of the axial resolution of a compact gamma camera with coded aperture collimator","title":"Assessment of the axial resolution of a compact gamma camera with coded aperture collimator"}]} | ||
| SRT | |a MEISSNERTOASSESSMENT2120 | ||