Towards substitution of invasive telemetry: an integrated home cage concept for unobtrusive monitoring of objective physiological parameters in rodents

This study presents a novel concept for a smart home cage design, tools, and software used to monitor the physiological parameters of mice and rats in animal-based experiments. The proposed system focuses on monitoring key clinical parameters, including heart rate, respiratory rate, and body tempera...

Full description

Saved in:
Bibliographic Details
Main Authors: Mösch, Lucas (Author) , Kunczik, Janosch (Author) , Breuer, Lukas (Author) , Merhof, Dorit (Author) , Gass, Peter (Author) , Potschka, Heidrun (Author) , Zechner, Dietmar (Author) , Vollmar, Brigitte (Author) , Tolba, René (Author) , Häger, Christine (Author) , Bleich, André (Author) , Czaplik, Michael (Author) , Barbosa Pereira, Carina (Author)
Format: Article (Journal)
Language:English
Published: September 7, 2023
In: PLOS ONE
Year: 2023, Volume: 18, Issue: 9, Pages: 1-19
ISSN:1932-6203
DOI:10.1371/journal.pone.0286230
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.1371/journal.pone.0286230
Verlag, kostenfrei, Volltext: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0286230
Get full text
Author Notes:Lucas Mösch, Janosch Kunczik, Lukas Breuer, Dorit Merhof, Peter Gass, Heidrun Potschka, Dietmar Zechner, Brigitte Vollmar, René Tolba, Christine Häger, André Bleich, Michael Czaplik, Carina Barbosa Pereira

MARC

LEADER 00000caa a2200000 c 4500
001 1899289933
003 DE-627
005 20241205164326.0
007 cr uuu---uuuuu
008 240821s2023 xx |||||o 00| ||eng c
024 7 |a 10.1371/journal.pone.0286230  |2 doi 
035 |a (DE-627)1899289933 
035 |a (DE-599)KXP1899289933 
035 |a (OCoLC)1475308630 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Mösch, Lucas  |e VerfasserIn  |0 (DE-588)1339548291  |0 (DE-627)1899179313  |4 aut 
245 1 0 |a Towards substitution of invasive telemetry  |b an integrated home cage concept for unobtrusive monitoring of objective physiological parameters in rodents  |c Lucas Mösch, Janosch Kunczik, Lukas Breuer, Dorit Merhof, Peter Gass, Heidrun Potschka, Dietmar Zechner, Brigitte Vollmar, René Tolba, Christine Häger, André Bleich, Michael Czaplik, Carina Barbosa Pereira 
264 1 |c September 7, 2023 
300 |b Illustrationen, Tabellen, Diagramme 
300 |a 19 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 21.08.2024 
520 |a This study presents a novel concept for a smart home cage design, tools, and software used to monitor the physiological parameters of mice and rats in animal-based experiments. The proposed system focuses on monitoring key clinical parameters, including heart rate, respiratory rate, and body temperature, and can also assess activity and circadian rhythm. As the basis of the smart home cage system, an in-depth analysis of the requirements was performed, including camera positioning, imaging system types, resolution, frame rates, external illumination, video acquisition, data storage, and synchronization. Two different camera perspectives were considered, and specific camera models, including two near-infrared and two thermal cameras, were selected to meet the requirements. The developed specifications, hardware models, and software are freely available via GitHub. During the first testing phase, the system demonstrated the potential of extracting vital parameters such as respiratory and heart rate. This technology has the potential to reduce the need for implantable sensors while providing reliable and accurate physiological data, leading to refinement and improvement in laboratory animal care. 
650 4 |a Animal welfare 
650 4 |a Cameras 
650 4 |a Circadian rhythms 
650 4 |a Computer hardware 
650 4 |a Light 
650 4 |a Near-infrared spectroscopy 
650 4 |a Physiological parameters 
650 4 |a Rodents 
700 1 |a Kunczik, Janosch  |e VerfasserIn  |4 aut 
700 1 |a Breuer, Lukas  |e VerfasserIn  |4 aut 
700 1 |a Merhof, Dorit  |e VerfasserIn  |4 aut 
700 1 |a Gass, Peter  |d 1963-  |e VerfasserIn  |0 (DE-588)13015945X  |0 (DE-627)492009694  |0 (DE-576)298033771  |4 aut 
700 1 |a Potschka, Heidrun  |d 1968-  |e VerfasserIn  |0 (DE-588)1052446922  |0 (DE-627)788514059  |0 (DE-576)408167890  |4 aut 
700 1 |a Zechner, Dietmar  |d 1969-  |e VerfasserIn  |0 (DE-588)1103836145  |0 (DE-627)861562283  |0 (DE-576)470784342  |4 aut 
700 1 |a Vollmar, Brigitte  |d 1961-  |e VerfasserIn  |0 (DE-588)136319564  |0 (DE-627)578555565  |0 (DE-576)300960565  |4 aut 
700 1 |a Tolba, René  |e VerfasserIn  |4 aut 
700 1 |a Häger, Christine  |e VerfasserIn  |4 aut 
700 1 |a Bleich, André  |e VerfasserIn  |4 aut 
700 1 |a Czaplik, Michael  |d 1979-  |e VerfasserIn  |0 (DE-588)13582284X  |0 (DE-627)571676901  |0 (DE-576)300665350  |4 aut 
700 1 |a Barbosa Pereira, Carina  |e VerfasserIn  |0 (DE-588)1162502231  |0 (DE-627)1026599342  |0 (DE-576)507436296  |4 aut 
773 0 8 |i Enthalten in  |t PLOS ONE  |d San Francisco, California, US : PLOS, 2006  |g 18(2023), 9, Artikel-ID e0286230, Seite 1-19  |h Online-Ressource  |w (DE-627)523574592  |w (DE-600)2267670-3  |w (DE-576)281331979  |x 1932-6203  |7 nnas  |a Towards substitution of invasive telemetry an integrated home cage concept for unobtrusive monitoring of objective physiological parameters in rodents 
773 1 8 |g volume:18  |g year:2023  |g number:9  |g elocationid:e0286230  |g pages:1-19  |g extent:19  |a Towards substitution of invasive telemetry an integrated home cage concept for unobtrusive monitoring of objective physiological parameters in rodents 
856 4 0 |u https://doi.org/10.1371/journal.pone.0286230  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0286230  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20240821 
993 |a Article 
994 |a 2023 
998 |g 13015945X  |a Gass, Peter  |m 13015945X:Gass, Peter  |d 60000  |e 60000PG13015945X  |k 0/60000/  |p 5 
999 |a KXP-PPN1899289933  |e 4569408540 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"name":{"displayForm":["Public Library of Science"]},"id":{"zdb":["2267670-3"],"eki":["523574592"],"issn":["1932-6203"]},"origin":[{"dateIssuedDisp":"2006-","publisher":"PLOS ; PLoS","dateIssuedKey":"2006","publisherPlace":"San Francisco, California, US ; Lawrence, Kan."}],"recId":"523574592","corporate":[{"roleDisplay":"Herausgebendes Organ","display":"Public Library of Science","role":"isb"}],"language":["eng"],"disp":"Towards substitution of invasive telemetry an integrated home cage concept for unobtrusive monitoring of objective physiological parameters in rodentsPLOS ONE","type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Schreibweise des Titels bis 2012: PLoS ONE","Gesehen am 20.03.19"],"part":{"pages":"1-19","issue":"9","year":"2023","extent":"19","text":"18(2023), 9, Artikel-ID e0286230, Seite 1-19","volume":"18"},"pubHistory":["1.2006 -"],"title":[{"title":"PLOS ONE","title_sort":"PLOS ONE"}]}],"physDesc":[{"extent":"19 S.","noteIll":"Illustrationen, Tabellen, Diagramme"}],"name":{"displayForm":["Lucas Mösch, Janosch Kunczik, Lukas Breuer, Dorit Merhof, Peter Gass, Heidrun Potschka, Dietmar Zechner, Brigitte Vollmar, René Tolba, Christine Häger, André Bleich, Michael Czaplik, Carina Barbosa Pereira"]},"id":{"doi":["10.1371/journal.pone.0286230"],"eki":["1899289933"]},"origin":[{"dateIssuedKey":"2023","dateIssuedDisp":"September 7, 2023"}],"recId":"1899289933","language":["eng"],"note":["Gesehen am 21.08.2024"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"role":"aut","display":"Mösch, Lucas","roleDisplay":"VerfasserIn","given":"Lucas","family":"Mösch"},{"display":"Kunczik, Janosch","roleDisplay":"VerfasserIn","role":"aut","family":"Kunczik","given":"Janosch"},{"roleDisplay":"VerfasserIn","display":"Breuer, Lukas","role":"aut","family":"Breuer","given":"Lukas"},{"given":"Dorit","family":"Merhof","role":"aut","display":"Merhof, Dorit","roleDisplay":"VerfasserIn"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Gass, Peter","given":"Peter","family":"Gass"},{"roleDisplay":"VerfasserIn","display":"Potschka, Heidrun","role":"aut","family":"Potschka","given":"Heidrun"},{"roleDisplay":"VerfasserIn","display":"Zechner, Dietmar","role":"aut","family":"Zechner","given":"Dietmar"},{"given":"Brigitte","family":"Vollmar","role":"aut","display":"Vollmar, Brigitte","roleDisplay":"VerfasserIn"},{"given":"René","family":"Tolba","role":"aut","roleDisplay":"VerfasserIn","display":"Tolba, René"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Häger, Christine","given":"Christine","family":"Häger"},{"given":"André","family":"Bleich","role":"aut","roleDisplay":"VerfasserIn","display":"Bleich, André"},{"given":"Michael","family":"Czaplik","role":"aut","display":"Czaplik, Michael","roleDisplay":"VerfasserIn"},{"given":"Carina","family":"Barbosa Pereira","role":"aut","display":"Barbosa Pereira, Carina","roleDisplay":"VerfasserIn"}],"title":[{"title_sort":"Towards substitution of invasive telemetry","subtitle":"an integrated home cage concept for unobtrusive monitoring of objective physiological parameters in rodents","title":"Towards substitution of invasive telemetry"}]} 
SRT |a MOESCHLUCATOWARDSSUB7202