Dosimetric study for breathing-induced motion effects in an abdominal pancreas phantom for carbon ion mini-beam radiotherapy

Background Particle mini-beam therapy exhibits promise in sparing healthy tissue through spatial fractionation, particularly notable for heavy ions, further enhancing the already favorable differential biological effectiveness at both target and entrance regions. However, breathing-induced organ mot...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Stengl, Christina (VerfasserIn) , Muñoz, Iván Domingo (VerfasserIn) , Arbes, Eric (VerfasserIn) , Rauth, Evelyn (VerfasserIn) , Christensen, Jeppe Brage (VerfasserIn) , Vedelago, José (VerfasserIn) , Runz, Armin (VerfasserIn) , Jäkel, Oliver (VerfasserIn) , Seco, Joao (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: August 2024
In: Medical physics
Year: 2024, Jahrgang: 51, Heft: 8, Pages: 5618-5631
ISSN:2473-4209
DOI:10.1002/mp.17077
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1002/mp.17077
Verlag, kostenfrei, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/mp.17077
Volltext
Verfasserangaben:Christina Stengl, Iván D. Muñoz, Eric Arbes, Evelyn Rauth, Jeppe B. Christensen, José Vedelago, Armin Runz, Oliver Jäkel, Joao Seco

MARC

LEADER 00000caa a2200000 c 4500
001 190232949X
003 DE-627
005 20250730164338.0
007 cr uuu---uuuuu
008 240911s2024 xx |||||o 00| ||eng c
024 7 |a 10.1002/mp.17077  |2 doi 
035 |a (DE-627)190232949X 
035 |a (DE-599)KXP190232949X 
035 |a (OCoLC)1475311460 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Stengl, Christina  |d 1997-  |e VerfasserIn  |0 (DE-588)1372195602  |0 (DE-627)193157782X  |4 aut 
245 1 0 |a Dosimetric study for breathing-induced motion effects in an abdominal pancreas phantom for carbon ion mini-beam radiotherapy  |c Christina Stengl, Iván D. Muñoz, Eric Arbes, Evelyn Rauth, Jeppe B. Christensen, José Vedelago, Armin Runz, Oliver Jäkel, Joao Seco 
264 1 |c August 2024 
300 |b Illustrationen 
300 |a 14 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online veröffentlicht: 17. April 2024 
500 |a Gesehen am 11.09.2024 
520 |a Background Particle mini-beam therapy exhibits promise in sparing healthy tissue through spatial fractionation, particularly notable for heavy ions, further enhancing the already favorable differential biological effectiveness at both target and entrance regions. However, breathing-induced organ motion affects particle mini-beam irradiation schemes since the organ displacements exceed the mini-beam structure dimensions, decreasing the advantages of spatial fractionation. Purpose In this study, the impact of breathing-induced organ motion on the dose distribution was examined at the target and organs at risk(OARs) during carbon ion mini-beam irradiation for pancreatic cancer. Methods As a first step, the carbon ion mini-beam pattern was characterized with Monte Carlo simulations. To analyze the impact of breathing-induced organ motion on the dose distribution of a virtual pancreas tumor as target and related OARs, the anthropomorphic Pancreas Phantom for Ion beam Therapy (PPIeT) was irradiated with carbon ions. A mini-beam collimator was used to deliver a spatially fractionated dose distribution. During irradiation, varying breathing motion amplitudes were induced, ranging from 5 to 15 mm. Post-irradiation, the 2D dose pattern was analyzed, focusing on the full width at half maximum (FWHM), center-to-center distance (ctc), and the peak-to-valley dose ratio (PVDR). Results The mini-beam pattern was visible within OARs, while in the virtual pancreas tumor a more homogeneous dose distribution was achieved. Applied motion affected the mini-beam pattern within the kidney, one of the OARs, reducing the PVDR from 3.78 ±\pm\ 0.12 to 1.478 ±\pm\ 0.070 for the 15 mm motion amplitude. In the immobile OARs including the spine and the skin at the back, the PVDR did not change within 3.4% comparing reference and motion conditions. Conclusions This study provides an initial understanding of how breathing-induced organ motion affects spatial fractionation during carbon ion irradiation, using an anthropomorphic phantom. A decrease in the PVDR was observed in the right kidney when breathing-induced motion was applied, potentially increasing the risk of damage to OARs. Therefore, further studies are needed to explore the clinical viability of mini-beam radiotherapy with carbon ions when irradiating abdominal regions. 
650 4 |a breathing-induced motion 
650 4 |a mini-beam irradiation 
650 4 |a pancreas phantom 
650 4 |a spatial fractionation 
700 1 |a Muñoz, Iván Domingo  |d 1984-  |e VerfasserIn  |0 (DE-588)1300351586  |0 (DE-627)1858138191  |4 aut 
700 1 |a Arbes, Eric  |e VerfasserIn  |0 (DE-588)1341660753  |0 (DE-627)1902332237  |4 aut 
700 1 |a Rauth, Evelyn  |e VerfasserIn  |0 (DE-588)134166015X  |0 (DE-627)1902331761  |4 aut 
700 1 |a Christensen, Jeppe Brage  |e VerfasserIn  |0 (DE-588)1300351934  |0 (DE-627)1858138582  |4 aut 
700 1 |a Vedelago, José  |e VerfasserIn  |0 (DE-588)1251835139  |0 (DE-627)1789602149  |4 aut 
700 1 |a Runz, Armin  |e VerfasserIn  |0 (DE-588)116699953X  |0 (DE-627)1030846480  |0 (DE-576)510993516  |4 aut 
700 1 |a Jäkel, Oliver  |d 1964-  |e VerfasserIn  |0 (DE-588)1050056302  |0 (DE-627)783260709  |0 (DE-576)404358705  |4 aut 
700 1 |a Seco, Joao  |e VerfasserIn  |0 (DE-588)1120955866  |0 (DE-627)874146615  |0 (DE-576)480627010  |4 aut 
773 0 8 |i Enthalten in  |t Medical physics  |d Hoboken, NJ : Wiley, 1974  |g 51(2024), 8 vom: Aug., Seite 5618-5631  |h Online-Ressource  |w (DE-627)265784867  |w (DE-600)1466421-5  |w (DE-576)074891243  |x 2473-4209  |7 nnas  |a Dosimetric study for breathing-induced motion effects in an abdominal pancreas phantom for carbon ion mini-beam radiotherapy 
773 1 8 |g volume:51  |g year:2024  |g number:8  |g month:08  |g pages:5618-5631  |g extent:14  |a Dosimetric study for breathing-induced motion effects in an abdominal pancreas phantom for carbon ion mini-beam radiotherapy 
856 4 0 |u https://doi.org/10.1002/mp.17077  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/mp.17077  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20240911 
993 |a Article 
994 |a 2024 
998 |g 1120955866  |a Seco, Joao  |m 1120955866:Seco, Joao  |d 130000  |e 130000PS1120955866  |k 0/130000/  |p 9  |y j 
998 |g 1050056302  |a Jäkel, Oliver  |m 1050056302:Jäkel, Oliver  |d 50000  |e 50000PJ1050056302  |k 0/50000/  |p 8 
998 |g 1251835139  |a Vedelago, José  |m 1251835139:Vedelago, José  |d 910000  |d 911400  |e 910000PV1251835139  |e 911400PV1251835139  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 134166015X  |a Rauth, Evelyn  |m 134166015X:Rauth, Evelyn  |p 4 
998 |g 1341660753  |a Arbes, Eric  |m 1341660753:Arbes, Eric  |p 3 
998 |g 1300351586  |a Muñoz, Iván Domingo  |m 1300351586:Muñoz, Iván Domingo  |d 910000  |d 911400  |e 910000PM1300351586  |e 911400PM1300351586  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 1372195602  |a Stengl, Christina  |m 1372195602:Stengl, Christina  |d 50000  |e 50000PS1372195602  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN190232949X  |e 457877760X 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"190232949X","physDesc":[{"noteIll":"Illustrationen","extent":"14 S."}],"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"August 2024"}],"person":[{"display":"Stengl, Christina","given":"Christina","role":"aut","family":"Stengl"},{"given":"Iván Domingo","role":"aut","family":"Muñoz","display":"Muñoz, Iván Domingo"},{"display":"Arbes, Eric","family":"Arbes","role":"aut","given":"Eric"},{"role":"aut","given":"Evelyn","family":"Rauth","display":"Rauth, Evelyn"},{"role":"aut","given":"Jeppe Brage","family":"Christensen","display":"Christensen, Jeppe Brage"},{"display":"Vedelago, José","role":"aut","given":"José","family":"Vedelago"},{"family":"Runz","role":"aut","given":"Armin","display":"Runz, Armin"},{"family":"Jäkel","role":"aut","given":"Oliver","display":"Jäkel, Oliver"},{"display":"Seco, Joao","family":"Seco","given":"Joao","role":"aut"}],"relHost":[{"origin":[{"dateIssuedKey":"1974","dateIssuedDisp":"1974-","publisherPlace":"Hoboken, NJ ; College Park, Md. ; New York, NY","publisher":"Wiley ; AAPM ; [Verlag nicht ermittelbar]"}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 01.08.2025"],"title":[{"title":"Medical physics","title_sort":"Medical physics"}],"physDesc":[{"extent":"Online-Ressource"}],"recId":"265784867","disp":"Dosimetric study for breathing-induced motion effects in an abdominal pancreas phantom for carbon ion mini-beam radiotherapyMedical physics","name":{"displayForm":["American Association of Physicists in Medicine ; American Institute of Physics"]},"titleAlt":[{"title":"Medical physics online"}],"pubHistory":["1.1974 -"],"id":{"zdb":["1466421-5"],"issn":["2473-4209","1522-8541"],"eki":["265784867"]},"part":{"year":"2024","volume":"51","pages":"5618-5631","issue":"8","extent":"14","text":"51(2024), 8 vom: Aug., Seite 5618-5631"}}],"title":[{"title":"Dosimetric study for breathing-induced motion effects in an abdominal pancreas phantom for carbon ion mini-beam radiotherapy","title_sort":"Dosimetric study for breathing-induced motion effects in an abdominal pancreas phantom for carbon ion mini-beam radiotherapy"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["Online veröffentlicht: 17. April 2024","Gesehen am 11.09.2024"],"name":{"displayForm":["Christina Stengl, Iván D. Muñoz, Eric Arbes, Evelyn Rauth, Jeppe B. Christensen, José Vedelago, Armin Runz, Oliver Jäkel, Joao Seco"]},"id":{"doi":["10.1002/mp.17077"],"eki":["190232949X"]}} 
SRT |a STENGLCHRIDOSIMETRIC2024