The application of a synthetic biodegradable temporizing matrix in extensive burn injury: a unicenter experience of 175 cases

Objectives: Addressing extensive and deep burn wounds poses considerable challenges for both patients and surgeons. The NovoSorb® Biodegradable Temporizing Matrix (BTM) emerged as a novel dermal substitute and has been subjected to evaluation in large burn wound cases, with a specific focus on ident...

Full description

Saved in:
Bibliographic Details
Main Authors: Tapking, Christian (Author) , Panayi, Adriana C. (Author) , Hundeshagen, Gabriel (Author) , Thomas, Benjamin (Author) , Gazyakan, Emre (Author) , Bliesener, Björn (Author) , Bigdeli, Amir Khosrow (Author) , Kneser, Ulrich (Author) , Vollbach, Felix Hubertus (Author)
Format: Article (Journal)
Language:English
Published: 1 May 2024
In: Journal of Clinical Medicine
Year: 2024, Volume: 13, Issue: 9, Pages: 2661-1-2661-12
ISSN:2077-0383
DOI:10.3390/jcm13092661
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.3390/jcm13092661
Verlag, lizenzpflichtig, Volltext: https://www.mdpi.com/2077-0383/13/9/2661
Get full text
Author Notes:Christian Tapking, Adriana C. Panayi, Gabriel Hundeshagen, Benjamin F. Thomas, Emre Gazyakan, Bjoern Bliesener, Amir K. Bigdeli, Ulrich Kneser and Felix H. Vollbach

MARC

LEADER 00000caa a2200000 c 4500
001 1903773016
003 DE-627
005 20241205174910.0
007 cr uuu---uuuuu
008 240930s2024 xx |||||o 00| ||eng c
024 7 |a 10.3390/jcm13092661  |2 doi 
035 |a (DE-627)1903773016 
035 |a (DE-599)KXP1903773016 
035 |a (OCoLC)1475313699 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Tapking, Christian  |d 1989-  |e VerfasserIn  |0 (DE-588)1160736014  |0 (DE-627)1024161870  |0 (DE-576)506160041  |4 aut 
245 1 4 |a The application of a synthetic biodegradable temporizing matrix in extensive burn injury  |b a unicenter experience of 175 cases  |c Christian Tapking, Adriana C. Panayi, Gabriel Hundeshagen, Benjamin F. Thomas, Emre Gazyakan, Bjoern Bliesener, Amir K. Bigdeli, Ulrich Kneser and Felix H. Vollbach 
264 1 |c 1 May 2024 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 30.09.2024 
520 |a Objectives: Addressing extensive and deep burn wounds poses considerable challenges for both patients and surgeons. The NovoSorb® Biodegradable Temporizing Matrix (BTM) emerged as a novel dermal substitute and has been subjected to evaluation in large burn wound cases, with a specific focus on identifying risk factors associated with suboptimal take rates. Methods: All patients with burn wounds greater than 10% body surface that underwent BTM treatment between March 2020 and November 2023 were eligible for inclusion. Univariate analyses and linear regression models were employed to discern risk factors and predictors influencing the take rates of both the BTM and split-thickness skin grafts (STSGs). Results: A total of 175 patients (mean age 56.2 ± 19.8 years, 70.3% male) were evaluated. The mean take rates of the BTM and STSGs were 82.0 ± 24.7% and 87.3 ± 19.0%, respectively. There were significant negative correlations between BTM take and the number of surgeries before BTM application (r = −0.19, p = 0.01), %TBSA and STSG take (r = −0.36, p = <0.001) and significant positive correlations between BTM and STSG take (r = 0.41, p ≤ 0.001) in addition to NPWT and STSG take (r = 0.21, p = 0.01). Multivariate regression analyses showed that a larger number of surgeries prior to BTM application (OR −3.41, 95% CI −6.82, −0.03, p = 0.04) was associated with poorer BTM take. Allograft treatment before BTM application (OR −14.7, 95% CI −23.0, −6.43,p = 0.01) and failed treatment with STSG before BTM application (OR −20.8, 95% CI −36.3, −5.23, p ≤ 0.01) were associated with poorer STSG take, whereas higher BTM take rates were associated with overall higher STSG take (OR −0.15, 95% 0.05, 0.26, p = 0.01). The Meek technique was used in 24 patients and showed similar take rates (BTM: 76.3 ± 28.0%, p = 0.22; STSG: 80.7 ± 21.1, p = 0.07). Conclusions: This study summarizes our findings on the application of a BTM in the context of large burn wounds. The results demonstrate that successful treatment can be achieved even in patients with extensive burns, resulting in satisfying take rates for both the BTM and STSG. The data underscore the importance of promptly applying a BTM to debrided wounds and indicate good results when using Meek. 
650 4 |a Biodegradable Temporizing Matrix 
650 4 |a BTM 
650 4 |a burns 
650 4 |a dermis substitute 
650 4 |a efficacy 
650 4 |a Meek 
650 4 |a risk factors 
700 1 |a Panayi, Adriana C.  |e VerfasserIn  |0 (DE-588)1219589268  |0 (DE-627)173552431X  |4 aut 
700 1 |a Hundeshagen, Gabriel  |d 1986-  |e VerfasserIn  |0 (DE-588)1058341057  |0 (DE-627)796708711  |0 (DE-576)414384938  |4 aut 
700 1 |a Thomas, Benjamin  |d 1988-  |e VerfasserIn  |0 (DE-588)1179968891  |0 (DE-627)1067579796  |0 (DE-576)518441296  |4 aut 
700 1 |a Gazyakan, Emre  |d 1973-  |e VerfasserIn  |0 (DE-588)123466563  |0 (DE-627)706309049  |0 (DE-576)293720916  |4 aut 
700 1 |a Bliesener, Björn  |d 1977-  |e VerfasserIn  |0 (DE-588)13024970X  |0 (DE-627)495830798  |0 (DE-576)298087553  |4 aut 
700 1 |a Bigdeli, Amir Khosrow  |d 1980-  |e VerfasserIn  |0 (DE-588)141636246  |0 (DE-627)630399433  |0 (DE-576)325071306  |4 aut 
700 1 |a Kneser, Ulrich  |d 1972-  |e VerfasserIn  |0 (DE-588)123065119  |0 (DE-627)706147219  |0 (DE-576)293539987  |4 aut 
700 1 |a Vollbach, Felix Hubertus  |e VerfasserIn  |0 (DE-588)125753985X  |0 (DE-627)1801818576  |4 aut 
773 0 8 |i Enthalten in  |t Journal of Clinical Medicine  |d Basel : MDPI, 2012  |g 13(2024), 9, Artikel-ID 2661, Seite 2661-1-2661-12  |h Online-Ressource  |w (DE-627)718632478  |w (DE-600)2662592-1  |w (DE-576)365782718  |x 2077-0383  |7 nnas  |a The application of a synthetic biodegradable temporizing matrix in extensive burn injury a unicenter experience of 175 cases 
773 1 8 |g volume:13  |g year:2024  |g number:9  |g elocationid:2661  |g pages:2661-1-2661-12  |g extent:12  |a The application of a synthetic biodegradable temporizing matrix in extensive burn injury a unicenter experience of 175 cases 
856 4 0 |u https://doi.org/10.3390/jcm13092661  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.mdpi.com/2077-0383/13/9/2661  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20240930 
993 |a Article 
994 |a 2024 
998 |g 123065119  |a Kneser, Ulrich  |m 123065119:Kneser, Ulrich  |d 50000  |e 50000PK123065119  |k 0/50000/  |p 8 
998 |g 141636246  |a Bigdeli, Amir Khosrow  |m 141636246:Bigdeli, Amir Khosrow  |d 50000  |e 50000PB141636246  |k 0/50000/  |p 7 
998 |g 123466563  |a Gazyakan, Emre  |m 123466563:Gazyakan, Emre  |d 50000  |e 50000PG123466563  |k 0/50000/  |p 5 
998 |g 1179968891  |a Thomas, Benjamin  |m 1179968891:Thomas, Benjamin  |p 4 
998 |g 1058341057  |a Hundeshagen, Gabriel  |m 1058341057:Hundeshagen, Gabriel  |d 50000  |e 50000PH1058341057  |k 0/50000/  |p 3 
999 |a KXP-PPN1903773016  |e 4584733368 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.3390/jcm13092661"],"eki":["1903773016"]},"title":[{"subtitle":"a unicenter experience of 175 cases","title":"The application of a synthetic biodegradable temporizing matrix in extensive burn injury","title_sort":"application of a synthetic biodegradable temporizing matrix in extensive burn injury"}],"recId":"1903773016","note":["Gesehen am 30.09.2024"],"person":[{"roleDisplay":"VerfasserIn","family":"Tapking","display":"Tapking, Christian","role":"aut","given":"Christian"},{"roleDisplay":"VerfasserIn","family":"Panayi","given":"Adriana C.","role":"aut","display":"Panayi, Adriana C."},{"given":"Gabriel","display":"Hundeshagen, Gabriel","role":"aut","family":"Hundeshagen","roleDisplay":"VerfasserIn"},{"given":"Benjamin","display":"Thomas, Benjamin","role":"aut","roleDisplay":"VerfasserIn","family":"Thomas"},{"roleDisplay":"VerfasserIn","family":"Gazyakan","role":"aut","display":"Gazyakan, Emre","given":"Emre"},{"display":"Bliesener, Björn","role":"aut","given":"Björn","roleDisplay":"VerfasserIn","family":"Bliesener"},{"given":"Amir Khosrow","display":"Bigdeli, Amir Khosrow","role":"aut","family":"Bigdeli","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","family":"Kneser","role":"aut","display":"Kneser, Ulrich","given":"Ulrich"},{"family":"Vollbach","roleDisplay":"VerfasserIn","display":"Vollbach, Felix Hubertus","role":"aut","given":"Felix Hubertus"}],"name":{"displayForm":["Christian Tapking, Adriana C. Panayi, Gabriel Hundeshagen, Benjamin F. Thomas, Emre Gazyakan, Bjoern Bliesener, Amir K. Bigdeli, Ulrich Kneser and Felix H. Vollbach"]},"physDesc":[{"extent":"12 S."}],"relHost":[{"disp":"The application of a synthetic biodegradable temporizing matrix in extensive burn injury a unicenter experience of 175 casesJournal of Clinical Medicine","note":["Gesehen am 12.06.20"],"title":[{"subtitle":"open access journal","title":"Journal of Clinical Medicine","title_sort":"Journal of Clinical Medicine"}],"id":{"issn":["2077-0383"],"eki":["718632478"],"zdb":["2662592-1"]},"type":{"media":"Online-Ressource","bibl":"periodical"},"origin":[{"dateIssuedDisp":"2012-","dateIssuedKey":"2012","publisherPlace":"Basel","publisher":"MDPI"}],"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"part":{"issue":"9","volume":"13","text":"13(2024), 9, Artikel-ID 2661, Seite 2661-1-2661-12","pages":"2661-1-2661-12","extent":"12","year":"2024"},"recId":"718632478","pubHistory":["1.2012 -"]}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedDisp":"1 May 2024","dateIssuedKey":"2024"}]} 
SRT |a TAPKINGCHRAPPLICATIO1202