Evaluation of parameters and nozzle tip damage after clinical use of three hydrophilic intraocular lens injector models

Purpose. To assess the nozzle tip damage and the parameters of three different hydrophilic intraocular lens (IOL) injector models. Methods. After routine cataract surgeries at the University Eye Hospital Heidelberg, all the used IOL injectors were collected from the operating room and sent to our la...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Zhang, Lu (VerfasserIn) , Schickhardt, Sonja (VerfasserIn) , Merz, Patrick (VerfasserIn) , Auffarth, Gerd U. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 30 May 2024
In: Journal of ophthalmology
Year: 2024, Pages: 1-8
ISSN:2090-0058
DOI:10.1155/2024/2360368
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1155/2024/2360368
Verlag, kostenfrei, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1155/2024/2360368
Volltext
Verfasserangaben:Lu Zhang, Sonja Schickhardt, Patrick Merz, and Gerd Uwe Auffarth

MARC

LEADER 00000caa a2200000 c 4500
001 1905362595
003 DE-627
005 20241205180511.0
007 cr uuu---uuuuu
008 241010s2024 xx |||||o 00| ||eng c
024 7 |a 10.1155/2024/2360368  |2 doi 
035 |a (DE-627)1905362595 
035 |a (DE-599)KXP1905362595 
035 |a (OCoLC)1475314961 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Zhang, Lu  |d 1990-  |e VerfasserIn  |0 (DE-588)1284342220  |0 (DE-627)1840086920  |4 aut 
245 1 0 |a Evaluation of parameters and nozzle tip damage after clinical use of three hydrophilic intraocular lens injector models  |c Lu Zhang, Sonja Schickhardt, Patrick Merz, and Gerd Uwe Auffarth 
264 1 |c 30 May 2024 
300 |b Illustrationen 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 10.10.2024 
520 |a Purpose. To assess the nozzle tip damage and the parameters of three different hydrophilic intraocular lens (IOL) injector models. Methods. After routine cataract surgeries at the University Eye Hospital Heidelberg, all the used IOL injectors were collected from the operating room and sent to our laboratory. Nozzle tip damage was assessed under a microscope and graded as follows: no damage (grade 0), slight scratches (1), deep scratches (2), extensions (3), cracks (4), and bursts (5). Each damage grade was assigned a score from 0 to 5, and the total damage score for each injector system was calculated and compared. Nozzle tip parameters (diameters and areas), plunger tip parameters, and tip angles were also measured in each model. Results. The damage scores were (median, Q3-Q1): 1 (1-1) for Accuject, 1 (1-1) for Bluemixs, and 1 (1-1) for RayOne. There was no statistically significant difference in the damage scores between the study groups (P > 0.05). The outer cross-sectional vertical and horizontal diameters were 1.69 and 1.69 mm for Accuject, 1.69 and 1.69 mm for Bluemixs, and 1.70 and 1.71 mm for RayOne. Plunger tip areas were 0.78 mm2 for Accjuect, 0.74 mm2 for Bluemixs, and 0.43 mm2 for RayOne. Plunger tip area/inner cross-sectional area of the nozzle tip (%) was 31.2% for RayOne, 66.7% for Accuject, and 63.8% for Bluemixs. The tip angles for three injector models were 56° (Accuject), 56° (Bluemixs), and 44° (RayOne). Conclusions. All the injector models showed mild to moderate damage to the nozzle tip after IOL implantation, even with smaller diameter tips. RayOne resulted in the lowest ratio between plunger tip area and inner cross-sectional area of the nozzle tip and a better distribution of damage categories than the other two groups. All three injector models had relatively small tip parameters. If smaller incisions are required in certain patients, smaller tip parameters should be considered. 
700 1 |a Schickhardt, Sonja  |e VerfasserIn  |0 (DE-588)121213723X  |0 (DE-627)1700745808  |4 aut 
700 1 |a Merz, Patrick  |e VerfasserIn  |0 (DE-588)1052826318  |0 (DE-627)789090384  |0 (DE-576)408561726  |4 aut 
700 1 |a Auffarth, Gerd U.  |d 1964-  |e VerfasserIn  |0 (DE-588)123385261  |0 (DE-627)577130420  |0 (DE-576)293687277  |4 aut 
773 0 8 |i Enthalten in  |t Journal of ophthalmology  |d [Hoboken, NJ] : Wiley, 2009  |g (2024), Artikel-ID 2360368, Seite 1-8  |h Online-Ressource  |w (DE-627)62318270X  |w (DE-600)2546525-9  |w (DE-576)321467523  |x 2090-0058  |7 nnas  |a Evaluation of parameters and nozzle tip damage after clinical use of three hydrophilic intraocular lens injector models 
773 1 8 |g year:2024  |g elocationid:2360368  |g pages:1-8  |g extent:8  |a Evaluation of parameters and nozzle tip damage after clinical use of three hydrophilic intraocular lens injector models 
856 4 0 |u https://doi.org/10.1155/2024/2360368  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1155/2024/2360368  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20241010 
993 |a Article 
994 |a 2024 
998 |g 123385261  |a Auffarth, Gerd U.  |m 123385261:Auffarth, Gerd U.  |d 910000  |d 910900  |e 910000PA123385261  |e 910900PA123385261  |k 0/910000/  |k 1/910000/910900/  |p 4  |y j 
998 |g 1052826318  |a Merz, Patrick  |m 1052826318:Merz, Patrick  |d 910000  |d 910900  |e 910000PM1052826318  |e 910900PM1052826318  |k 0/910000/  |k 1/910000/910900/  |p 3 
998 |g 121213723X  |a Schickhardt, Sonja  |m 121213723X:Schickhardt, Sonja  |d 910000  |d 910900  |e 910000PS121213723X  |e 910900PS121213723X  |k 0/910000/  |k 1/910000/910900/  |p 2 
998 |g 1284342220  |a Zhang, Lu  |m 1284342220:Zhang, Lu  |p 1  |x j 
999 |a KXP-PPN1905362595  |e 4591106772 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"note":["Gesehen am 10.10.2024"],"relHost":[{"language":["eng"],"pubHistory":["2009 -"],"title":[{"title_sort":"Journal of ophthalmology","title":"Journal of ophthalmology"}],"disp":"Evaluation of parameters and nozzle tip damage after clinical use of three hydrophilic intraocular lens injector modelsJournal of ophthalmology","origin":[{"dateIssuedDisp":"2024-","dateIssuedKey":"2024","publisherPlace":"[Hoboken, NJ] ; New York, NY","publisher":"Wiley ; Hindawi"}],"part":{"pages":"1-8","extent":"8","text":"(2024), Artikel-ID 2360368, Seite 1-8","year":"2024"},"id":{"zdb":["2546525-9"],"eki":["62318270X"],"issn":["2090-0058"]},"note":["Gesehen am 08.09.2021"],"recId":"62318270X","physDesc":[{"extent":"Online-Ressource"}],"type":{"bibl":"periodical","media":"Online-Ressource"}}],"recId":"1905362595","physDesc":[{"extent":"8 S.","noteIll":"Illustrationen"}],"name":{"displayForm":["Lu Zhang, Sonja Schickhardt, Patrick Merz, and Gerd Uwe Auffarth"]},"title":[{"title_sort":"Evaluation of parameters and nozzle tip damage after clinical use of three hydrophilic intraocular lens injector models","title":"Evaluation of parameters and nozzle tip damage after clinical use of three hydrophilic intraocular lens injector models"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"eki":["1905362595"],"doi":["10.1155/2024/2360368"]},"person":[{"given":"Lu","family":"Zhang","display":"Zhang, Lu","role":"aut"},{"display":"Schickhardt, Sonja","role":"aut","family":"Schickhardt","given":"Sonja"},{"given":"Patrick","family":"Merz","role":"aut","display":"Merz, Patrick"},{"family":"Auffarth","role":"aut","display":"Auffarth, Gerd U.","given":"Gerd U."}],"origin":[{"dateIssuedDisp":"30 May 2024","dateIssuedKey":"2024"}]} 
SRT |a ZHANGLUSCHEVALUATION3020