Potential of photon counting computed tomography derived spectral reconstructions to reduce beam-hardening artifacts in chest CT

Purpose - Aim of the recent study is to point out a method to optimize quality of CT scans in oncological patients with port systems. This study investigates the potential of photon counting computed tomography (PCCT) for reduction of beam hardening artifacts caused by port-implants in chest imaging...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Haag, Florian (VerfasserIn) , Große Hokamp, Nils (VerfasserIn) , Overhoff, Daniel (VerfasserIn) , Dasegowda, Giridhar (VerfasserIn) , Kuru, Mustafa (VerfasserIn) , Nörenberg, Dominik (VerfasserIn) , Schönberg, Stefan (VerfasserIn) , Kalra, Mannudeep K. (VerfasserIn) , Froelich, Matthias F. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 29 March 2024
In: European journal of radiology
Year: 2024, Jahrgang: 175, Pages: 111448-1-111448-11
ISSN:1872-7727
DOI:10.1016/j.ejrad.2024.111448
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ejrad.2024.111448
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X24001645
Volltext
Verfasserangaben:Florian Haag, Nils Große Hokamp, Daniel Overhoff, Giridhar Dasegowda, Mustafa Kuru, Dominik Nörenberg, Stefan O. Schoenberg, Mannudeep K. Kalra, Matthias F. Froelich

MARC

LEADER 00000caa a2200000 c 4500
001 1907035478
003 DE-627
005 20241220171137.0
007 cr uuu---uuuuu
008 241028s2024 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejrad.2024.111448  |2 doi 
035 |a (DE-627)1907035478 
035 |a (DE-599)KXP1907035478 
035 |a (OCoLC)1475324371 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Haag, Florian  |e VerfasserIn  |0 (DE-588)1304252728  |0 (DE-627)1860419259  |4 aut 
245 1 0 |a Potential of photon counting computed tomography derived spectral reconstructions to reduce beam-hardening artifacts in chest CT  |c Florian Haag, Nils Große Hokamp, Daniel Overhoff, Giridhar Dasegowda, Mustafa Kuru, Dominik Nörenberg, Stefan O. Schoenberg, Mannudeep K. Kalra, Matthias F. Froelich 
264 1 |c 29 March 2024 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 28.10.2024 
520 |a Purpose - Aim of the recent study is to point out a method to optimize quality of CT scans in oncological patients with port systems. This study investigates the potential of photon counting computed tomography (PCCT) for reduction of beam hardening artifacts caused by port-implants in chest imaging by means of spectral reconstructions. - Method - In this retrospective single-center study, 8 ROIs for 19 spectral reconstructions (polyenergetic imaging, monoenergetic reconstructions from 40 to 190 keV as well as iodine maps and virtual non contrast (VNC)) of 49 patients with pectoral port systems undergoing PCCT of the chest for staging of oncologic disease were measured. Mean values and standard deviation (SD) Hounsfield unit measurements of port-chamber associated hypo- and hyperdense artifacts, bilateral muscles and vessels has been carried out. Also, a structured assessment of artifacts and imaging findings was performed by two radiologists. - Results - A significant association of keV with iodine contrast as well as artifact intensity was noted (all p < 0.001). In qualitative assessment, utilization of 120 keV monoenergetic reconstructions could reduce severe and pronounced artifacts completely, as compared to lower keV reconstructions (p < 0.001). Regarding imaging findings, no significant difference between monoenergetic reconstructions was noted (all p > 0.05). In cases with very high iodine concentrations in the subclavian vein, image distortions were noted at 40 keV images (p < 0.01). - Conclusions - The present study demonstrates that PCCT derived spectral reconstructions can be used in oncological imaging of the thorax to reduce port-derived beam-hardening artefacts. When evaluating image data sets within a staging, it can be particularly helpful to consider the 120 keV VMIs, in which the artefacts are comparatively low. 
650 4 |a Artifacts 
650 4 |a Photon Counting Computed Tomography 
650 4 |a Port system 
650 4 |a Protocol optimization 
650 4 |a Staging 
700 1 |a Große Hokamp, Nils  |d 1988-  |e VerfasserIn  |0 (DE-588)1147488991  |0 (DE-627)1006213716  |0 (DE-576)495817007  |4 aut 
700 1 |a Overhoff, Daniel  |d 1984-  |e VerfasserIn  |0 (DE-588)1098192257  |0 (DE-627)85747944X  |0 (DE-576)469013397  |4 aut 
700 1 |a Dasegowda, Giridhar  |e VerfasserIn  |4 aut 
700 1 |a Kuru, Mustafa  |d 1995-  |e VerfasserIn  |0 (DE-588)1344150012  |0 (DE-627)1904904017  |4 aut 
700 1 |a Nörenberg, Dominik  |e VerfasserIn  |0 (DE-588)1064719996  |0 (DE-627)814432123  |0 (DE-576)424084228  |4 aut 
700 1 |a Schönberg, Stefan  |d 1969-  |e VerfasserIn  |0 (DE-588)131557912  |0 (DE-627)510700624  |0 (DE-576)298584891  |4 aut 
700 1 |a Kalra, Mannudeep K.  |e VerfasserIn  |0 (DE-588)136151833  |0 (DE-627)59933553X  |0 (DE-576)306309602  |4 aut 
700 1 |a Froelich, Matthias F.  |d 1991-  |e VerfasserIn  |0 (DE-588)1170833756  |0 (DE-627)1040131557  |0 (DE-576)512678359  |4 aut 
773 0 8 |i Enthalten in  |t European journal of radiology  |d Amsterdam [u.a.] : Elsevier Science, 1990  |g 175(2024), Artikel-ID 111448, Seite 111448-1-111448-11  |h Online-Ressource  |w (DE-627)32044483X  |w (DE-600)2005350-2  |w (DE-576)099718138  |x 1872-7727  |7 nnas  |a Potential of photon counting computed tomography derived spectral reconstructions to reduce beam-hardening artifacts in chest CT 
773 1 8 |g volume:175  |g year:2024  |g elocationid:111448  |g pages:111448-1-111448-11  |g extent:11  |a Potential of photon counting computed tomography derived spectral reconstructions to reduce beam-hardening artifacts in chest CT 
856 4 0 |u https://doi.org/10.1016/j.ejrad.2024.111448  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0720048X24001645  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20241028 
993 |a Article 
994 |a 2024 
998 |g 1344150012  |a Kuru, Mustafa  |m 1344150012:Kuru, Mustafa  |d 60000  |e 60000PK1344150012  |k 0/60000/  |p 5 
998 |g 1170833756  |a Froelich, Matthias F.  |m 1170833756:Froelich, Matthias F.  |d 60000  |d 62900  |d 60000  |e 60000PF1170833756  |e 62900PF1170833756  |e 60000PF1170833756  |k 0/60000/  |k 1/60000/62900/  |k 0/60000/  |p 9  |y j 
998 |g 131557912  |a Schönberg, Stefan  |m 131557912:Schönberg, Stefan  |d 60000  |d 62900  |e 60000PS131557912  |e 62900PS131557912  |k 0/60000/  |k 1/60000/62900/  |p 4 
998 |g 1064719996  |a Nörenberg, Dominik  |m 1064719996:Nörenberg, Dominik  |d 60000  |d 62900  |e 60000PN1064719996  |e 62900PN1064719996  |k 0/60000/  |k 1/60000/62900/  |p 3 
998 |g 1098192257  |a Overhoff, Daniel  |m 1098192257:Overhoff, Daniel  |d 60000  |d 62900  |e 60000PO1098192257  |e 62900PO1098192257  |k 0/60000/  |k 1/60000/62900/  |p 2 
998 |g 1304252728  |a Haag, Florian  |m 1304252728:Haag, Florian  |d 60000  |d 62900  |e 60000PH1304252728  |e 62900PH1304252728  |k 0/60000/  |k 1/60000/62900/  |p 1  |x j 
999 |a KXP-PPN1907035478  |e 4603619715 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"disp":"Potential of photon counting computed tomography derived spectral reconstructions to reduce beam-hardening artifacts in chest CTEuropean journal of radiology","note":["Gesehen am 05.02.20"],"id":{"zdb":["2005350-2"],"eki":["32044483X"],"issn":["1872-7727"]},"title":[{"subtitle":"EJR","title":"European journal of radiology","title_sort":"European journal of radiology"}],"origin":[{"dateIssuedDisp":"1990-","publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1990","publisher":"Elsevier Science"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"part":{"text":"175(2024), Artikel-ID 111448, Seite 111448-1-111448-11","volume":"175","year":"2024","extent":"11","pages":"111448-1-111448-11"},"recId":"32044483X","pubHistory":["Nachgewiesen 10.1990 -"],"titleAlt":[{"title":"EJR"}]}],"physDesc":[{"extent":"11 S."}],"person":[{"given":"Florian","role":"aut","display":"Haag, Florian","roleDisplay":"VerfasserIn","family":"Haag"},{"family":"Große Hokamp","roleDisplay":"VerfasserIn","role":"aut","display":"Große Hokamp, Nils","given":"Nils"},{"display":"Overhoff, Daniel","role":"aut","given":"Daniel","roleDisplay":"VerfasserIn","family":"Overhoff"},{"family":"Dasegowda","roleDisplay":"VerfasserIn","given":"Giridhar","display":"Dasegowda, Giridhar","role":"aut"},{"given":"Mustafa","role":"aut","display":"Kuru, Mustafa","family":"Kuru","roleDisplay":"VerfasserIn"},{"given":"Dominik","display":"Nörenberg, Dominik","role":"aut","family":"Nörenberg","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","family":"Schönberg","given":"Stefan","display":"Schönberg, Stefan","role":"aut"},{"given":"Mannudeep K.","display":"Kalra, Mannudeep K.","role":"aut","family":"Kalra","roleDisplay":"VerfasserIn"},{"given":"Matthias F.","role":"aut","display":"Froelich, Matthias F.","roleDisplay":"VerfasserIn","family":"Froelich"}],"name":{"displayForm":["Florian Haag, Nils Große Hokamp, Daniel Overhoff, Giridhar Dasegowda, Mustafa Kuru, Dominik Nörenberg, Stefan O. Schoenberg, Mannudeep K. Kalra, Matthias F. Froelich"]},"language":["eng"],"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"29 March 2024"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 28.10.2024"],"title":[{"title":"Potential of photon counting computed tomography derived spectral reconstructions to reduce beam-hardening artifacts in chest CT","title_sort":"Potential of photon counting computed tomography derived spectral reconstructions to reduce beam-hardening artifacts in chest CT"}],"id":{"doi":["10.1016/j.ejrad.2024.111448"],"eki":["1907035478"]},"recId":"1907035478"} 
SRT |a HAAGFLORIAPOTENTIALO2920