Josephson voltage standards as ultra-stable low-noise voltage sources for precision Penning-trap experiments

A high-precision Penning-trap experiment was operated with a programmable 20 V Josephson voltage source, providing a significantly higher stability of the electrostatic trapping potential. This increased the motional frequency stability of a trapped ion by about a factor of two with respect to state...

Full description

Saved in:
Bibliographic Details
Main Authors: Kaiser, Annabelle (Author) , Dickopf, Stefan (Author) , Door, Menno (Author) , Behr, R. (Author) , Beutel, Ute (Author) , Eliseev, Sergey (Author) , Kaushik, A. (Author) , Kromer, K. (Author) , Müller, M. (Author) , Palafox, L. (Author) , Ulmer, S. (Author) , Mooser, Andreas (Author) , Blaum, Klaus (Author)
Format: Article (Journal)
Language:English
Published: 30 May 2024
In: Applied physics letters
Year: 2024, Volume: 124, Issue: 22, Pages: 224002-1-224002-8
ISSN:1077-3118
DOI:10.1063/5.0206779
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.1063/5.0206779
Get full text
Author Notes:A. Kaiser, S. Dickopf, M. Door, R. Behr, U. Beutel, S. Eliseev, A. Kaushik, K. Kromer, M. Müller, L. Palafox, S. Ulmer, A. Mooser, and K. Blaum

MARC

LEADER 00000caa a2200000 c 4500
001 1908129344
003 DE-627
005 20241205185331.0
007 cr uuu---uuuuu
008 241111s2024 xx |||||o 00| ||eng c
024 7 |a 10.1063/5.0206779  |2 doi 
035 |a (DE-627)1908129344 
035 |a (DE-599)KXP1908129344 
035 |a (OCoLC)1475637763 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Kaiser, Annabelle  |e VerfasserIn  |0 (DE-588)1347872280  |0 (DE-627)190813268X  |4 aut 
245 1 0 |a Josephson voltage standards as ultra-stable low-noise voltage sources for precision Penning-trap experiments  |c A. Kaiser, S. Dickopf, M. Door, R. Behr, U. Beutel, S. Eliseev, A. Kaushik, K. Kromer, M. Müller, L. Palafox, S. Ulmer, A. Mooser, and K. Blaum 
264 1 |c 30 May 2024 
300 |b Illustrationen 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 11.11.2024 
520 |a A high-precision Penning-trap experiment was operated with a programmable 20 V Josephson voltage source, providing a significantly higher stability of the electrostatic trapping potential. This increased the motional frequency stability of a trapped ion by about a factor of two with respect to state-of-the-art voltage sources. An absolute axial frequency stability of 7.8(6) mHz corresponding to a relative precision of 9.7 (8) × 10 - 9 at 795 kHz was demonstrated using a trapped 9Be3+ ion as a measurement probe. The enhanced stability in the trapping potential opens up the possibility for improved determinations of the proton and antiproton magnetic moments and direct high-precision measurements of the nuclear magnetic moments of 2H, 3He, and 7Li. In the field of mass spectrometry, the developments will enable measurements of cyclotron frequency ratios and, thus, mass ratio measurements with unprecedented relative statistical uncertainties below the 10-12 level. 
700 1 |a Dickopf, Stefan  |d 1994-  |e VerfasserIn  |0 (DE-588)1335342338  |0 (DE-627)1895145139  |4 aut 
700 1 |a Door, Menno  |d 1990-  |e VerfasserIn  |0 (DE-588)1223185567  |0 (DE-627)1742598439  |4 aut 
700 1 |a Behr, R.  |e VerfasserIn  |4 aut 
700 1 |a Beutel, Ute  |e VerfasserIn  |0 (DE-588)1347877673  |0 (DE-627)1908134046  |4 aut 
700 1 |a Eliseev, Sergey  |e VerfasserIn  |0 (DE-588)1213492416  |0 (DE-627)1724149385  |4 aut 
700 1 |a Kaushik, A.  |e VerfasserIn  |4 aut 
700 1 |a Kromer, K.  |e VerfasserIn  |4 aut 
700 1 |a Müller, M.  |e VerfasserIn  |4 aut 
700 1 |a Palafox, L.  |e VerfasserIn  |4 aut 
700 1 |a Ulmer, S.  |e VerfasserIn  |4 aut 
700 1 |a Mooser, Andreas  |d 1982-  |e VerfasserIn  |0 (DE-588)1051351278  |0 (DE-627)78605137X  |0 (DE-576)406386684  |4 aut 
700 1 |a Blaum, Klaus  |d 1971-  |e VerfasserIn  |0 (DE-588)122580079  |0 (DE-627)082030170  |0 (DE-576)293334382  |4 aut 
773 0 8 |i Enthalten in  |t Applied physics letters  |d Melville, NY : American Inst. of Physics, 1962  |g 124(2024), 22 vom: Mai, Artikel-ID 224002, Seite 224002-1-224002-8  |h Online-Ressource  |w (DE-627)267324952  |w (DE-600)1469436-0  |w (DE-576)077052501  |x 1077-3118  |7 nnas  |a Josephson voltage standards as ultra-stable low-noise voltage sources for precision Penning-trap experiments 
773 1 8 |g volume:124  |g year:2024  |g number:22  |g month:05  |g elocationid:224002  |g pages:224002-1-224002-8  |g extent:8  |a Josephson voltage standards as ultra-stable low-noise voltage sources for precision Penning-trap experiments 
856 4 0 |u https://doi.org/10.1063/5.0206779  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20241111 
993 |a Article 
994 |a 2024 
998 |g 122580079  |a Blaum, Klaus  |m 122580079:Blaum, Klaus  |d 130000  |e 130000PB122580079  |k 0/130000/  |p 13  |y j 
998 |g 1347877673  |a Beutel, Ute  |m 1347877673:Beutel, Ute  |d 130000  |e 130000PB1347877673  |k 0/130000/  |p 5 
998 |g 1223185567  |a Door, Menno  |m 1223185567:Door, Menno  |d 130000  |e 130000PD1223185567  |k 0/130000/  |p 3 
999 |a KXP-PPN1908129344  |e 4612932293 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.1063/5.0206779"],"eki":["1908129344"]},"physDesc":[{"extent":"8 S.","noteIll":"Illustrationen"}],"note":["Gesehen am 11.11.2024"],"recId":"1908129344","type":{"media":"Online-Ressource","bibl":"article-journal"},"person":[{"roleDisplay":"VerfasserIn","role":"aut","family":"Kaiser","given":"Annabelle","display":"Kaiser, Annabelle"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Dickopf, Stefan","family":"Dickopf","given":"Stefan"},{"roleDisplay":"VerfasserIn","role":"aut","given":"Menno","family":"Door","display":"Door, Menno"},{"roleDisplay":"VerfasserIn","role":"aut","family":"Behr","given":"R.","display":"Behr, R."},{"display":"Beutel, Ute","given":"Ute","family":"Beutel","role":"aut","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","role":"aut","given":"Sergey","family":"Eliseev","display":"Eliseev, Sergey"},{"roleDisplay":"VerfasserIn","role":"aut","family":"Kaushik","given":"A.","display":"Kaushik, A."},{"display":"Kromer, K.","given":"K.","family":"Kromer","role":"aut","roleDisplay":"VerfasserIn"},{"display":"Müller, M.","family":"Müller","given":"M.","role":"aut","roleDisplay":"VerfasserIn"},{"display":"Palafox, L.","given":"L.","family":"Palafox","role":"aut","roleDisplay":"VerfasserIn"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Ulmer, S.","family":"Ulmer","given":"S."},{"role":"aut","roleDisplay":"VerfasserIn","display":"Mooser, Andreas","family":"Mooser","given":"Andreas"},{"roleDisplay":"VerfasserIn","role":"aut","family":"Blaum","given":"Klaus","display":"Blaum, Klaus"}],"relHost":[{"recId":"267324952","name":{"displayForm":["publ. by the American Institute of Physics"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"1962","publisherPlace":"Melville, NY","publisher":"American Inst. of Physics","dateIssuedDisp":"1962-"}],"language":["eng"],"title":[{"title":"Applied physics letters","title_sort":"Applied physics letters"}],"disp":"Josephson voltage standards as ultra-stable low-noise voltage sources for precision Penning-trap experimentsApplied physics letters","part":{"pages":"224002-1-224002-8","year":"2024","extent":"8","text":"124(2024), 22 vom: Mai, Artikel-ID 224002, Seite 224002-1-224002-8","issue":"22","volume":"124"},"id":{"zdb":["1469436-0"],"issn":["1077-3118"],"eki":["267324952"]},"corporate":[{"role":"isb","roleDisplay":"Herausgebendes Organ","display":"American Institute of Physics"}],"physDesc":[{"extent":"Online-Ressource"}],"pubHistory":["1.1962 -"],"note":["Gesehen am 17.10.13"],"titleAlt":[{"title":"Applied physics letters online"}]}],"name":{"displayForm":["A. Kaiser, S. Dickopf, M. Door, R. Behr, U. Beutel, S. Eliseev, A. Kaushik, K. Kromer, M. Müller, L. Palafox, S. Ulmer, A. Mooser, and K. Blaum"]},"language":["eng"],"origin":[{"dateIssuedDisp":"30 May 2024","dateIssuedKey":"2024"}],"title":[{"title":"Josephson voltage standards as ultra-stable low-noise voltage sources for precision Penning-trap experiments","title_sort":"Josephson voltage standards as ultra-stable low-noise voltage sources for precision Penning-trap experiments"}]} 
SRT |a KAISERANNAJOSEPHSONV3020