Comparing quantitative image parameters between animal and clinical CT-scanners: a translational phantom study analysis
<sec id="sec1"><title>Purpose</title><p>This study compares phantom-based variability of extracted radiomics features from scans on a photon counting CT (PCCT) and an experimental animal PET/CT-scanner (Albira II) to investigate the potential of radiomics for transl...
Saved in:
| Main Authors: | , , , , , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
05 June 2024
|
| In: |
Frontiers in medicine
Year: 2024, Volume: 11, Pages: 1-9 |
| ISSN: | 2296-858X |
| DOI: | 10.3389/fmed.2024.1407235 |
| Online Access: | Verlag, kostenfrei, Volltext: https://doi.org/10.3389/fmed.2024.1407235 Verlag, kostenfrei, Volltext: https://www.frontiersin.org/journals/medicine/articles/10.3389/fmed.2024.1407235/full |
| Author Notes: | Abhinay Vellala, Carolin Mogler, Florian Haag, Fabian Tollens, Henning Rudolf, Friedrich Pietsch, Carmen Wängler, Björn Wängler, Stefan O. Schoenberg, Matthias F. Froelich and Alexander Hertel |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1908236108 | ||
| 003 | DE-627 | ||
| 005 | 20241205215849.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 241111s2024 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.3389/fmed.2024.1407235 |2 doi | |
| 035 | |a (DE-627)1908236108 | ||
| 035 | |a (DE-599)KXP1908236108 | ||
| 035 | |a (OCoLC)1475647093 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Vellala, Abhinay K. |e VerfasserIn |0 (DE-588)1310903700 |0 (DE-627)1871004810 |4 aut | |
| 245 | 1 | 0 | |a Comparing quantitative image parameters between animal and clinical CT-scanners |b a translational phantom study analysis |c Abhinay Vellala, Carolin Mogler, Florian Haag, Fabian Tollens, Henning Rudolf, Friedrich Pietsch, Carmen Wängler, Björn Wängler, Stefan O. Schoenberg, Matthias F. Froelich and Alexander Hertel |
| 264 | 1 | |c 05 June 2024 | |
| 300 | |b Illustrationen | ||
| 300 | |a 9 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 11.11.2024 | ||
| 520 | |a <sec id="sec1"><title>Purpose</title><p>This study compares phantom-based variability of extracted radiomics features from scans on a photon counting CT (PCCT) and an experimental animal PET/CT-scanner (Albira II) to investigate the potential of radiomics for translation from animal models to human scans. While oncological basic research in animal PET/CT has allowed an intrinsic comparison between PET and CT, but no 1:1 translation to a human CT scanner due to resolution and noise limitations, Radiomics as a statistical and thus scale-independent method can potentially close the critical gap.</p></sec><sec id="sec2"><title>Methods</title><p>Two phantoms were scanned on a PCCT and animal PET/CT-scanner with different scan parameters and then the radiomics parameters were extracted. A Principal Component Analysis (PCA) was conducted. To overcome the limitation of a small dataset, a data augmentation technique was applied. A Ridge Classifier was trained and a Feature Importance- and Cluster analysis was performed.</p></sec><sec id="sec3"><title>Results</title><p>PCA and Cluster Analysis shows a clear differentiation between phantom types while emphasizing the comparability of both scanners. The Ridge Classifier exhibited a strong training performance with 93% accuracy, but faced challenges in generalization with a test accuracy of 62%.</p></sec><sec id="sec4"><title>Conclusion</title><p>These results show that radiomics has great potential as a translational tool between animal models and human routine diagnostics, especially using the novel photon counting technique. This is another crucial step towards integration of radiomics analysis into clinical practice.</p></sec> | ||
| 650 | 4 | |a Animal Models | |
| 650 | 4 | |a Diagnostic integration | |
| 650 | 4 | |a Photon counting CT | |
| 650 | 4 | |a Radiomics | |
| 650 | 4 | |a translation | |
| 700 | 1 | |a Mogler, Carolin |d 1980- |e VerfasserIn |0 (DE-588)139825827 |0 (DE-627)613790766 |0 (DE-576)313435995 |4 aut | |
| 700 | 1 | |a Haag, Florian |e VerfasserIn |0 (DE-588)1304252728 |0 (DE-627)1860419259 |4 aut | |
| 700 | 1 | |a Tollens, Fabian |d 1993- |e VerfasserIn |0 (DE-588)1158694911 |0 (DE-627)1020771615 |0 (DE-576)504310925 |4 aut | |
| 700 | 1 | |a Rudolf, Henning |e VerfasserIn |0 (DE-588)1044452633 |0 (DE-627)772065624 |0 (DE-576)397674406 |4 aut | |
| 700 | 1 | |a Pietsch, Friedrich L. |d 2001- |e VerfasserIn |0 (DE-588)1347241817 |0 (DE-627)190758580X |4 aut | |
| 700 | 1 | |a Wängler, Carmen |d 1978- |e VerfasserIn |0 (DE-588)133775593 |0 (DE-627)556368177 |0 (DE-576)30009230X |4 aut | |
| 700 | 1 | |a Wängler, Björn |d 1975- |e VerfasserIn |0 (DE-588)129702218 |0 (DE-627)477593909 |0 (DE-576)297793888 |4 aut | |
| 700 | 1 | |a Schönberg, Stefan |d 1969- |e VerfasserIn |0 (DE-588)131557912 |0 (DE-627)510700624 |0 (DE-576)298584891 |4 aut | |
| 700 | 1 | |a Froelich, Matthias F. |d 1991- |e VerfasserIn |0 (DE-588)1170833756 |0 (DE-627)1040131557 |0 (DE-576)512678359 |4 aut | |
| 700 | 1 | |a Hertel, Alexander |d 1994- |e VerfasserIn |0 (DE-588)1259070824 |0 (DE-627)1805891758 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Frontiers in medicine |d Lausanne : Frontiers Media, 2014 |g 11(2024) vom: 5. Juni, Artikel-ID 1407235, Seite 1-9 |h Online-Ressource |w (DE-627)789482991 |w (DE-600)2775999-4 |w (DE-576)408729597 |x 2296-858X |7 nnas |a Comparing quantitative image parameters between animal and clinical CT-scanners a translational phantom study analysis |
| 773 | 1 | 8 | |g volume:11 |g year:2024 |g day:5 |g month:06 |g elocationid:1407235 |g pages:1-9 |g extent:9 |a Comparing quantitative image parameters between animal and clinical CT-scanners a translational phantom study analysis |
| 856 | 4 | 0 | |u https://doi.org/10.3389/fmed.2024.1407235 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://www.frontiersin.org/journals/medicine/articles/10.3389/fmed.2024.1407235/full |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20241111 | ||
| 993 | |a Article | ||
| 994 | |a 2024 | ||
| 998 | |g 1259070824 |a Hertel, Alexander |m 1259070824:Hertel, Alexander |p 11 |y j | ||
| 998 | |g 1170833756 |a Froelich, Matthias F. |m 1170833756:Froelich, Matthias F. |d 60000 |d 62900 |d 60000 |e 60000PF1170833756 |e 62900PF1170833756 |e 60000PF1170833756 |k 0/60000/ |k 1/60000/62900/ |k 0/60000/ |p 10 | ||
| 998 | |g 131557912 |a Schönberg, Stefan |m 131557912:Schönberg, Stefan |d 60000 |d 62900 |e 60000PS131557912 |e 62900PS131557912 |k 0/60000/ |k 1/60000/62900/ |p 9 | ||
| 998 | |g 129702218 |a Wängler, Björn |m 129702218:Wängler, Björn |d 60000 |d 62900 |e 60000PW129702218 |e 62900PW129702218 |k 0/60000/ |k 1/60000/62900/ |p 8 | ||
| 998 | |g 133775593 |a Wängler, Carmen |m 133775593:Wängler, Carmen |d 60000 |d 62900 |d 60000 |e 60000PW133775593 |e 62900PW133775593 |e 60000PW133775593 |k 0/60000/ |k 1/60000/62900/ |k 0/60000/ |p 7 | ||
| 998 | |g 1347241817 |a Pietsch, Friedrich L. |m 1347241817:Pietsch, Friedrich L. |p 6 | ||
| 998 | |g 1044452633 |a Rudolf, Henning |m 1044452633:Rudolf, Henning |d 60000 |d 62900 |e 60000PR1044452633 |e 62900PR1044452633 |k 0/60000/ |k 1/60000/62900/ |p 5 | ||
| 998 | |g 1158694911 |a Tollens, Fabian |m 1158694911:Tollens, Fabian |d 60000 |d 62900 |e 60000PT1158694911 |e 62900PT1158694911 |k 0/60000/ |k 1/60000/62900/ |p 4 | ||
| 998 | |g 1304252728 |a Haag, Florian |m 1304252728:Haag, Florian |d 60000 |d 62900 |e 60000PH1304252728 |e 62900PH1304252728 |k 0/60000/ |k 1/60000/62900/ |p 3 | ||
| 998 | |g 1310903700 |a Vellala, Abhinay K. |m 1310903700:Vellala, Abhinay K. |d 60000 |d 62900 |e 60000PV1310903700 |e 62900PV1310903700 |k 0/60000/ |k 1/60000/62900/ |p 1 |x j | ||
| 999 | |a KXP-PPN1908236108 |e 461317984X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"person":[{"given":"Abhinay K.","role":"aut","display":"Vellala, Abhinay K.","family":"Vellala"},{"family":"Mogler","role":"aut","given":"Carolin","display":"Mogler, Carolin"},{"display":"Haag, Florian","role":"aut","given":"Florian","family":"Haag"},{"display":"Tollens, Fabian","given":"Fabian","role":"aut","family":"Tollens"},{"display":"Rudolf, Henning","role":"aut","given":"Henning","family":"Rudolf"},{"family":"Pietsch","display":"Pietsch, Friedrich L.","role":"aut","given":"Friedrich L."},{"display":"Wängler, Carmen","role":"aut","given":"Carmen","family":"Wängler"},{"family":"Wängler","given":"Björn","role":"aut","display":"Wängler, Björn"},{"family":"Schönberg","display":"Schönberg, Stefan","given":"Stefan","role":"aut"},{"given":"Matthias F.","role":"aut","display":"Froelich, Matthias F.","family":"Froelich"},{"family":"Hertel","role":"aut","given":"Alexander","display":"Hertel, Alexander"}],"name":{"displayForm":["Abhinay Vellala, Carolin Mogler, Florian Haag, Fabian Tollens, Henning Rudolf, Friedrich Pietsch, Carmen Wängler, Björn Wängler, Stefan O. Schoenberg, Matthias F. Froelich and Alexander Hertel"]},"relHost":[{"title":[{"title":"Frontiers in medicine","title_sort":"Frontiers in medicine"}],"language":["eng"],"part":{"pages":"1-9","extent":"9","volume":"11","text":"11(2024) vom: 5. Juni, Artikel-ID 1407235, Seite 1-9","year":"2024"},"pubHistory":["2014 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"FMED"},{"title":"Front. Med."}],"recId":"789482991","origin":[{"publisherPlace":"Lausanne","dateIssuedKey":"2014","publisher":"Frontiers Media","dateIssuedDisp":"2014-"}],"disp":"Comparing quantitative image parameters between animal and clinical CT-scanners a translational phantom study analysisFrontiers in medicine","id":{"eki":["789482991"],"zdb":["2775999-4"],"issn":["2296-858X"]},"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 09.02.2021"]}],"note":["Gesehen am 11.11.2024"],"physDesc":[{"extent":"9 S.","noteIll":"Illustrationen"}],"id":{"eki":["1908236108"],"doi":["10.3389/fmed.2024.1407235"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"05 June 2024"}],"recId":"1908236108","language":["eng"],"title":[{"title":"Comparing quantitative image parameters between animal and clinical CT-scanners","subtitle":"a translational phantom study analysis","title_sort":"Comparing quantitative image parameters between animal and clinical CT-scanners"}]} | ||
| SRT | |a VELLALAABHCOMPARINGQ0520 | ||