Diagnostic accuracy of optic nerve head and macula OCT parameters for detecting glaucoma in eyes with and without high axial myopia

Purpose - To characterize structural differences and assess the diagnostic accuracy of optic nerve head (ONH) and macula optical coherence tomography (OCT) parameters to detect glaucoma in eyes with and without high axial myopia. - Design - Cross-sectional study. - Methods - Three hundred sixty-eigh...

Full description

Saved in:
Bibliographic Details
Main Authors: Rezapour, Jasmin (Author) , Walker, Evan (Author) , Belghith, Akram (Author) , Bowd, Chrisotpher (Author) , Fazio, Massimo A. (Author) , Jiravarnsirikul, Anuwat (Author) , Hyman, Leslie (Author) , Jonas, Jost B. (Author) , Weinreb, Robert N. (Author) , Zangwill, Linda M. (Author)
Format: Article (Journal)
Language:English
Published: October 2024
In: American journal of ophthalmology
Year: 2024, Volume: 266, Pages: 77-91
ISSN:1879-1891
DOI:10.1016/j.ajo.2024.04.022
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ajo.2024.04.022
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S000293942400165X
Get full text
Author Notes:Jasmin Rezapour, Evan Walker, Akram Belghith, Christopher Bowd, Massimo A. Fazio, Anuwat Jiravarnsirikul, Leslie Hyman, Jost B. Jonas, Robert N. Weinreb, and Linda M. Zangwill

MARC

LEADER 00000caa a2200000 c 4500
001 1909072826
003 DE-627
005 20241205221709.0
007 cr uuu---uuuuu
008 241120s2024 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ajo.2024.04.022  |2 doi 
035 |a (DE-627)1909072826 
035 |a (DE-599)KXP1909072826 
035 |a (OCoLC)1475647725 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Rezapour, Jasmin  |d 1988-  |e VerfasserIn  |0 (DE-588)1074554957  |0 (DE-627)832289752  |0 (DE-576)442742959  |4 aut 
245 1 0 |a Diagnostic accuracy of optic nerve head and macula OCT parameters for detecting glaucoma in eyes with and without high axial myopia  |c Jasmin Rezapour, Evan Walker, Akram Belghith, Christopher Bowd, Massimo A. Fazio, Anuwat Jiravarnsirikul, Leslie Hyman, Jost B. Jonas, Robert N. Weinreb, and Linda M. Zangwill 
264 1 |c October 2024 
300 |b Illustrationen 
300 |a 15 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online verfügbar: 15. Mai 2024, Artikelversion: 10. Juni 2024 
500 |a Gesehen am 20.11.2024 
520 |a Purpose - To characterize structural differences and assess the diagnostic accuracy of optic nerve head (ONH) and macula optical coherence tomography (OCT) parameters to detect glaucoma in eyes with and without high axial myopia. - Design - Cross-sectional study. - Methods - Three hundred sixty-eight glaucoma and 411 healthy eyes with no axial myopia, 393 glaucoma and 271 healthy eyes with mild axial myopia and 124 glaucoma and 85 healthy eyes with high axial myopia were included. Global and sectoral peripapillary retinal nerve fiber layer thickness (pRNFLT), Bruch's membrane opening minimum rim width (BMO-MRW), ganglion cell inner plexiform layer thickness (GCIPLT), and macula RNFLT (mRNFLT) were compared and the diagnostic accuracy for glaucoma detection was evaluated using the adjusted area under the receiver operating characteristic curve (AUC). - Results - Diagnostic accuracy for ONH and macula parameters to detect glaucoma was generally high and differed by myopia group. For ONH parameters the diagnostic accuracy was highest for global (AUC = 0.95) and inferotemporal (AUC = 0.91) pRNFLT for high myopes and global BMO-MRW for nonmyopes (AUC = 1.0) and mild myopes (AUC = 0.97). For macula parameters, the diagnostic accuracy was higher in high myopes with 6 of the 11 GCIPLT global/sectors having adjusted AUCs > 0.90 compared to nonhigh myopes with no AUCs > 0.90. In all myopia groups, mRNFLT had lower AUCs than GCIPLT. - Conclusions - The diagnostic accuracy for pRNFL and GCIPL was high for high axial myopic eyes and shows promise for glaucoma detection in high myopes. Further analysis is needed to determine whether the high diagnostic accuracy can be confirmed in other populations. 
700 1 |a Walker, Evan  |e VerfasserIn  |4 aut 
700 1 |a Belghith, Akram  |e VerfasserIn  |4 aut 
700 1 |a Bowd, Chrisotpher  |e VerfasserIn  |4 aut 
700 1 |a Fazio, Massimo A.  |e VerfasserIn  |4 aut 
700 1 |a Jiravarnsirikul, Anuwat  |e VerfasserIn  |4 aut 
700 1 |a Hyman, Leslie  |e VerfasserIn  |4 aut 
700 1 |a Jonas, Jost B.  |d 1958-  |e VerfasserIn  |0 (DE-588)1028286732  |0 (DE-627)730536823  |0 (DE-576)37578537X  |4 aut 
700 1 |a Weinreb, Robert N.  |e VerfasserIn  |4 aut 
700 1 |a Zangwill, Linda M.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t American journal of ophthalmology  |d New York, NY : Elsevier Science, 1918  |g 266(2024), Seite 77-91  |h Online-Ressource  |w (DE-627)320596281  |w (DE-600)2019600-3  |w (DE-576)121466353  |x 1879-1891  |7 nnas  |a Diagnostic accuracy of optic nerve head and macula OCT parameters for detecting glaucoma in eyes with and without high axial myopia 
773 1 8 |g volume:266  |g year:2024  |g pages:77-91  |g extent:15  |a Diagnostic accuracy of optic nerve head and macula OCT parameters for detecting glaucoma in eyes with and without high axial myopia 
856 4 0 |u https://doi.org/10.1016/j.ajo.2024.04.022  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S000293942400165X  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20241120 
993 |a Article 
994 |a 2024 
998 |g 1028286732  |a Jonas, Jost B.  |m 1028286732:Jonas, Jost B.  |d 60000  |e 60000PJ1028286732  |k 0/60000/  |p 8 
999 |a KXP-PPN1909072826  |e 4617022376 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Online verfügbar: 15. Mai 2024, Artikelversion: 10. Juni 2024","Gesehen am 20.11.2024"],"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"October 2024"}],"title":[{"title_sort":"Diagnostic accuracy of optic nerve head and macula OCT parameters for detecting glaucoma in eyes with and without high axial myopia","title":"Diagnostic accuracy of optic nerve head and macula OCT parameters for detecting glaucoma in eyes with and without high axial myopia"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1909072826","relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"name":{"displayForm":["Frank W. Newell, ed.-in-chief [u.a.]"]},"recId":"320596281","id":{"eki":["320596281"],"issn":["1879-1891"],"zdb":["2019600-3"]},"title":[{"title":"American journal of ophthalmology","subtitle":"AJO","title_sort":"American journal of ophthalmology"}],"note":["Gesehen am 21.09.2020","Ungezählte Beil.: Supplement"],"pubHistory":["Nachgewiesen 3.Ser. 1.1918 -"],"origin":[{"publisher":"Elsevier Science","dateIssuedKey":"1918","dateIssuedDisp":"1918-","publisherPlace":"New York, NY"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Diagnostic accuracy of optic nerve head and macula OCT parameters for detecting glaucoma in eyes with and without high axial myopiaAmerican journal of ophthalmology","language":["eng"],"titleAlt":[{"title":"AJO"}],"part":{"volume":"266","extent":"15","text":"266(2024), Seite 77-91","pages":"77-91","year":"2024"}}],"name":{"displayForm":["Jasmin Rezapour, Evan Walker, Akram Belghith, Christopher Bowd, Massimo A. Fazio, Anuwat Jiravarnsirikul, Leslie Hyman, Jost B. Jonas, Robert N. Weinreb, and Linda M. Zangwill"]},"physDesc":[{"noteIll":"Illustrationen","extent":"15 S."}],"id":{"doi":["10.1016/j.ajo.2024.04.022"],"eki":["1909072826"]},"person":[{"role":"aut","given":"Jasmin","family":"Rezapour","display":"Rezapour, Jasmin"},{"role":"aut","given":"Evan","display":"Walker, Evan","family":"Walker"},{"family":"Belghith","display":"Belghith, Akram","given":"Akram","role":"aut"},{"role":"aut","given":"Chrisotpher","family":"Bowd","display":"Bowd, Chrisotpher"},{"given":"Massimo A.","role":"aut","family":"Fazio","display":"Fazio, Massimo A."},{"display":"Jiravarnsirikul, Anuwat","family":"Jiravarnsirikul","given":"Anuwat","role":"aut"},{"display":"Hyman, Leslie","family":"Hyman","role":"aut","given":"Leslie"},{"family":"Jonas","display":"Jonas, Jost B.","given":"Jost B.","role":"aut"},{"role":"aut","given":"Robert N.","display":"Weinreb, Robert N.","family":"Weinreb"},{"family":"Zangwill","display":"Zangwill, Linda M.","given":"Linda M.","role":"aut"}],"language":["eng"]} 
SRT |a REZAPOURJADIAGNOSTIC2024