Semi-automated reproducible target transfer for cardiac radioablation - A multi-center cross-validation study within the RAVENTA trial

Background - Stereotactic arrhythmia radioablation (STAR) is a therapeutic option for ventricular tachycardia (VT) where catheter-based ablation is not feasible or has previously failed. Target definition and its transfer from electro-anatomic maps (EAM) to radiotherapy treatment planning systems (T...

Full description

Saved in:
Bibliographic Details
Main Authors: Hohmann, Stephan (Author) , Xie, Jingyang (Author) , Eckl, Miriam (Author) , Grehn, Melanie (Author) , Karfoul, Nizar (Author) , Janorschke, Christian (Author) , Merten, Roland (Author) , Rudic, Boris (Author) , Bürgy, Daniel (Author) , Lyan, Evgeny (Author) , Krug, David (Author) , Mehrhof, Felix (Author) , Boldt, Leif-Hendrik (Author) , Corradini, Stefanie (Author) , Fanslau, Hannah (Author) , Kästner, Lena (Author) , Zaman, Adrian (Author) , Giordano, Frank Anton (Author) , Duncker, David (Author) , Dunst, Jürgen (Author) , Tilz, Roland R. (Author) , Schweikard, Achim (Author) , Blanck, Oliver (Author) , Boda-Heggemann, Judit (Author)
Format: Article (Journal)
Language:English
Published: November 2024
In: Radiotherapy and oncology
Year: 2024, Volume: 200, Pages: 1-8
ISSN:1879-0887
DOI:10.1016/j.radonc.2024.110499
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.radonc.2024.110499
Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S0167814024007692
Get full text
Author Notes:Stephan Hohmann, Jingyang Xie, Miriam Eckl, Melanie Grehn, Nizar Karfoul, Christian Janorschke, Roland Merten, Boris Rudic, Daniel Buergy, Evgeny Lyan, David Krug, Felix Mehrhof, Leif-Hendrik Boldt, Stefanie Corradini, Hannah Fanslau, Lena Kaestner, Adrian Zaman, Frank A. Giordano, David Duncker, Jürgen Dunst, Roland R. Tilz, Achim Schweikard, Oliver Blanck, Judit Boda-Heggemann

MARC

LEADER 00000caa a2200000 c 4500
001 1909455695
003 DE-627
005 20250214123513.0
007 cr uuu---uuuuu
008 241125s2024 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.radonc.2024.110499  |2 doi 
035 |a (DE-627)1909455695 
035 |a (DE-599)KXP1909455695 
035 |a (OCoLC)1475648153 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hohmann, Stephan  |e VerfasserIn  |0 (DE-588)1165354241  |0 (DE-627)1029437009  |0 (DE-576)510382827  |4 aut 
245 1 0 |a Semi-automated reproducible target transfer for cardiac radioablation - A multi-center cross-validation study within the RAVENTA trial  |c Stephan Hohmann, Jingyang Xie, Miriam Eckl, Melanie Grehn, Nizar Karfoul, Christian Janorschke, Roland Merten, Boris Rudic, Daniel Buergy, Evgeny Lyan, David Krug, Felix Mehrhof, Leif-Hendrik Boldt, Stefanie Corradini, Hannah Fanslau, Lena Kaestner, Adrian Zaman, Frank A. Giordano, David Duncker, Jürgen Dunst, Roland R. Tilz, Achim Schweikard, Oliver Blanck, Judit Boda-Heggemann 
264 1 |c November 2024 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online veröffentlicht: 4. September 2024, Artikelversion: 11. September 2024 
500 |a Gesehen am 25.11.2024 
520 |a Background - Stereotactic arrhythmia radioablation (STAR) is a therapeutic option for ventricular tachycardia (VT) where catheter-based ablation is not feasible or has previously failed. Target definition and its transfer from electro-anatomic maps (EAM) to radiotherapy treatment planning systems (TPS) is challenging and operator-dependent. Software solutions have been developed to register EAM with cardiac CT and semi-automatically transfer 2D target surface data into 3D CT volume coordinates. Results of a cross-validation study of two conceptually different software solutions using data from the RAVENTA trial (NCT03867747) are reported. - Methods - Clinical Target Volumes (CTVs) were created from target regions delineated on EAM using two conceptually different approaches by separate investigators on data of 10 patients, blinded to each other’s results. Targets were transferred using 3D-3D registration and 2D-3D registration, respectively. The resulting CTVs were compared in a core-lab using two complementary analysis software packages for structure similarity and geometric characteristics. - Results - Volumes and surface areas of the CTVs created by both methods were comparable: 14.88 ± 11.72 ml versus 15.15 ± 11.35 ml and 44.29 ± 33.63 cm2 versus 46.43 ± 35.13 cm2. The Dice-coefficient was 0.84 ± 0.04; median surface-distance and Hausdorff-distance were 0.53 ± 0.37 mm and 6.91 ± 2.26 mm, respectively. The 3D-center-of-mass difference was 3.62 ± 0.99 mm. Geometrical volume similarity was 0.94 ± 0.05 %. - Conclusion - The STAR targets transferred from EAM to TPS using both software solutions resulted in nearly identical 3D structures. Both solutions can be used for QA (quality assurance) and EAM-to-TPS transfer of STAR-targets. Semi-automated methods could potentially help to avoid mistargeting in STAR and offer standardized workflows for methodically harmonized treatments. 
650 4 |a CARDIO-RT 
650 4 |a Cross-validation 
650 4 |a EAMapReader 
650 4 |a Quality assurance 
650 4 |a RAVENTA 
650 4 |a Semi-automated software solutions 
650 4 |a STAR 
650 4 |a Stereotactic Arrhythmia Radioablation 
650 4 |a Target transfer 
650 4 |a Target volume definition 
650 4 |a Ventricular tachycardia 
700 1 |a Xie, Jingyang  |e VerfasserIn  |4 aut 
700 1 |a Eckl, Miriam  |d 1992-  |e VerfasserIn  |0 (DE-588)1162098538  |0 (DE-627)1025541596  |0 (DE-576)507186419  |4 aut 
700 1 |a Grehn, Melanie  |e VerfasserIn  |4 aut 
700 1 |a Karfoul, Nizar  |e VerfasserIn  |4 aut 
700 1 |a Janorschke, Christian  |e VerfasserIn  |4 aut 
700 1 |a Merten, Roland  |e VerfasserIn  |4 aut 
700 1 |a Rudic, Boris  |d 1982-  |e VerfasserIn  |0 (DE-588)1024726789  |0 (DE-627)720427134  |0 (DE-576)369410599  |4 aut 
700 1 |a Bürgy, Daniel  |d 1980-  |e VerfasserIn  |0 (DE-588)141653779  |0 (DE-627)630406472  |0 (DE-576)325119031  |4 aut 
700 1 |a Lyan, Evgeny  |e VerfasserIn  |4 aut 
700 1 |a Krug, David  |e VerfasserIn  |0 (DE-588)1062940202  |0 (DE-627)807054747  |0 (DE-576)420297944  |4 aut 
700 1 |a Mehrhof, Felix  |e VerfasserIn  |4 aut 
700 1 |a Boldt, Leif-Hendrik  |d 1975-  |e VerfasserIn  |0 (DE-588)1072857413  |0 (DE-627)828415935  |0 (DE-576)434295299  |4 aut 
700 1 |a Corradini, Stefanie  |d 1984-  |e VerfasserIn  |0 (DE-588)1179853687  |0 (DE-627)1067534946  |0 (DE-576)518389340  |4 aut 
700 1 |a Fanslau, Hannah  |d 1999-  |e VerfasserIn  |0 (DE-588)1323289496  |0 (DE-627)1883296307  |4 aut 
700 1 |a Kästner, Lena  |d 1994-  |e VerfasserIn  |0 (DE-588)1255067608  |0 (DE-627)1798138344  |4 aut 
700 1 |a Zaman, Adrian  |e VerfasserIn  |4 aut 
700 1 |a Giordano, Frank Anton  |d 1980-  |e VerfasserIn  |0 (DE-588)136378455  |0 (DE-627)694333093  |0 (DE-576)300990529  |4 aut 
700 1 |a Duncker, David  |e VerfasserIn  |4 aut 
700 1 |a Dunst, Jürgen  |e VerfasserIn  |4 aut 
700 1 |a Tilz, Roland R.  |e VerfasserIn  |4 aut 
700 1 |a Schweikard, Achim  |e VerfasserIn  |4 aut 
700 1 |a Blanck, Oliver  |e VerfasserIn  |0 (DE-588)115998106X  |0 (DE-627)1023098768  |0 (DE-576)505430649  |4 aut 
700 1 |a Boda-Heggemann, Judit  |d 1977-  |e VerfasserIn  |0 (DE-588)1029853436  |0 (DE-627)734363087  |0 (DE-576)377699411  |4 aut 
773 0 8 |i Enthalten in  |t Radiotherapy and oncology  |d Amsterdam [u.a.] : Elsevier Science, 1983  |g 200(2024), Artikel-ID 110499, Seite 1-8  |h Online-Ressource  |w (DE-627)306710110  |w (DE-600)1500707-8  |w (DE-576)082435731  |x 1879-0887  |7 nnas  |a Semi-automated reproducible target transfer for cardiac radioablation - A multi-center cross-validation study within the RAVENTA trial 
773 1 8 |g volume:200  |g year:2024  |g elocationid:110499  |g pages:1-8  |g extent:8  |a Semi-automated reproducible target transfer for cardiac radioablation - A multi-center cross-validation study within the RAVENTA trial 
856 4 0 |u https://doi.org/10.1016/j.radonc.2024.110499  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0167814024007692  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20241125 
993 |a Article 
994 |a 2024 
998 |g 1029853436  |a Boda-Heggemann, Judit  |m 1029853436:Boda-Heggemann, Judit  |d 60000  |d 63000  |d 60000  |e 60000PB1029853436  |e 63000PB1029853436  |e 60000PB1029853436  |k 0/60000/  |k 1/60000/63000/  |k 0/60000/  |p 24  |y j 
998 |g 136378455  |a Giordano, Frank Anton  |m 136378455:Giordano, Frank Anton  |d 60000  |e 60000PG136378455  |k 0/60000/  |p 18 
998 |g 1255067608  |a Kästner, Lena  |m 1255067608:Kästner, Lena  |p 16 
998 |g 1323289496  |a Fanslau, Hannah  |m 1323289496:Fanslau, Hannah  |d 60000  |e 60000PF1323289496  |k 0/60000/  |p 15 
998 |g 141653779  |a Bürgy, Daniel  |m 141653779:Bürgy, Daniel  |d 60000  |d 63000  |e 60000PB141653779  |e 63000PB141653779  |k 0/60000/  |k 1/60000/63000/  |p 9 
998 |g 1024726789  |a Rudic, Boris  |m 1024726789:Rudic, Boris  |d 60000  |d 61000  |e 60000PR1024726789  |e 61000PR1024726789  |k 0/60000/  |k 1/60000/61000/  |p 8 
998 |g 1162098538  |a Eckl, Miriam  |m 1162098538:Eckl, Miriam  |d 60000  |e 60000PE1162098538  |k 0/60000/  |p 3 
999 |a KXP-PPN1909455695  |e 4622130505 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"person":[{"role":"aut","given":"Stephan","family":"Hohmann","display":"Hohmann, Stephan"},{"given":"Jingyang","role":"aut","display":"Xie, Jingyang","family":"Xie"},{"role":"aut","given":"Miriam","display":"Eckl, Miriam","family":"Eckl"},{"display":"Grehn, Melanie","family":"Grehn","role":"aut","given":"Melanie"},{"family":"Karfoul","display":"Karfoul, Nizar","given":"Nizar","role":"aut"},{"display":"Janorschke, Christian","family":"Janorschke","given":"Christian","role":"aut"},{"role":"aut","given":"Roland","family":"Merten","display":"Merten, Roland"},{"display":"Rudic, Boris","family":"Rudic","given":"Boris","role":"aut"},{"given":"Daniel","role":"aut","display":"Bürgy, Daniel","family":"Bürgy"},{"family":"Lyan","display":"Lyan, Evgeny","role":"aut","given":"Evgeny"},{"role":"aut","given":"David","family":"Krug","display":"Krug, David"},{"given":"Felix","role":"aut","display":"Mehrhof, Felix","family":"Mehrhof"},{"role":"aut","given":"Leif-Hendrik","family":"Boldt","display":"Boldt, Leif-Hendrik"},{"family":"Corradini","display":"Corradini, Stefanie","role":"aut","given":"Stefanie"},{"given":"Hannah","role":"aut","display":"Fanslau, Hannah","family":"Fanslau"},{"role":"aut","given":"Lena","family":"Kästner","display":"Kästner, Lena"},{"given":"Adrian","role":"aut","family":"Zaman","display":"Zaman, Adrian"},{"display":"Giordano, Frank Anton","family":"Giordano","role":"aut","given":"Frank Anton"},{"given":"David","role":"aut","display":"Duncker, David","family":"Duncker"},{"family":"Dunst","display":"Dunst, Jürgen","given":"Jürgen","role":"aut"},{"role":"aut","given":"Roland R.","display":"Tilz, Roland R.","family":"Tilz"},{"family":"Schweikard","display":"Schweikard, Achim","role":"aut","given":"Achim"},{"role":"aut","given":"Oliver","family":"Blanck","display":"Blanck, Oliver"},{"family":"Boda-Heggemann","display":"Boda-Heggemann, Judit","given":"Judit","role":"aut"}],"name":{"displayForm":["Stephan Hohmann, Jingyang Xie, Miriam Eckl, Melanie Grehn, Nizar Karfoul, Christian Janorschke, Roland Merten, Boris Rudic, Daniel Buergy, Evgeny Lyan, David Krug, Felix Mehrhof, Leif-Hendrik Boldt, Stefanie Corradini, Hannah Fanslau, Lena Kaestner, Adrian Zaman, Frank A. Giordano, David Duncker, Jürgen Dunst, Roland R. Tilz, Achim Schweikard, Oliver Blanck, Judit Boda-Heggemann"]},"physDesc":[{"extent":"8 S."}],"relHost":[{"disp":"Semi-automated reproducible target transfer for cardiac radioablation - A multi-center cross-validation study within the RAVENTA trialRadiotherapy and oncology","type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 30.05.15","Ungezählte Beil.: Supplement"],"pubHistory":["1.1983 -"],"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedDisp":"1983-","publisher":"Elsevier Science","dateIssuedKey":"1983"}],"title":[{"subtitle":"journal of the European Society for Therapeutic Radiology and Oncology","title_sort":"Radiotherapy and oncology","title":"Radiotherapy and oncology"}],"id":{"eki":["306710110"],"issn":["1879-0887"],"zdb":["1500707-8"]},"recId":"306710110","physDesc":[{"extent":"Online-Ressource"}],"part":{"extent":"8","text":"200(2024), Artikel-ID 110499, Seite 1-8","volume":"200","pages":"1-8","year":"2024"},"titleAlt":[{"title":"The green journal"}],"language":["eng"]}],"recId":"1909455695","id":{"eki":["1909455695"],"doi":["10.1016/j.radonc.2024.110499"]},"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"November 2024"}],"note":["Online veröffentlicht: 4. September 2024, Artikelversion: 11. September 2024","Gesehen am 25.11.2024"],"title":[{"title_sort":"Semi-automated reproducible target transfer for cardiac radioablation - A multi-center cross-validation study within the RAVENTA trial","title":"Semi-automated reproducible target transfer for cardiac radioablation - A multi-center cross-validation study within the RAVENTA trial"}],"type":{"media":"Online-Ressource","bibl":"article-journal"}} 
SRT |a HOHMANNSTESEMIAUTOMA2024