A servo-control system for open- and closed-loop blood pressure regulation

An electropneumatic servo-control system is described that can reduce and control arterial blood pressure in experimental animals. The device has been proved useful in the analysis of pressure-dependent physiological processes and allows the following two modes of operation: 1) a conventional open-l...

Full description

Saved in:
Bibliographic Details
Main Authors: Nafz, Benno (Author) , Persson, Pontus B. (Author) , Ehmke, Heimo (Author) , Kirchheim, Hartmut (Author)
Format: Article (Journal)
Language:English
Published: February 1992
In: American journal of physiology. Renal physiology
Year: 1992, Volume: 262, Issue: 2, Pages: F320-F325
ISSN:1522-1466
DOI:10.1152/ajprenal.1992.262.2.F320
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1152/ajprenal.1992.262.2.F320
Verlag, lizenzpflichtig, Volltext: https://journals.physiology.org/doi/abs/10.1152/ajprenal.1992.262.2.F320
Get full text
Author Notes:B. Nafz, P.B. Persson, H. Ehmke, H.R. Kirchheim

MARC

LEADER 00000caa a2200000 c 4500
001 1909464678
003 DE-627
005 20241205222703.0
007 cr uuu---uuuuu
008 241125s1992 xx |||||o 00| ||eng c
024 7 |a 10.1152/ajprenal.1992.262.2.F320  |2 doi 
035 |a (DE-627)1909464678 
035 |a (DE-599)KXP1909464678 
035 |a (OCoLC)1475648073 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Nafz, Benno  |d 1966-  |e VerfasserIn  |0 (DE-588)129456179  |0 (DE-627)397663471  |0 (DE-576)297668781  |4 aut 
245 1 2 |a A servo-control system for open- and closed-loop blood pressure regulation  |c B. Nafz, P.B. Persson, H. Ehmke, H.R. Kirchheim 
264 1 |c February 1992 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 25.11.2025 
520 |a An electropneumatic servo-control system is described that can reduce and control arterial blood pressure in experimental animals. The device has been proved useful in the analysis of pressure-dependent physiological processes and allows the following two modes of operation: 1) a conventional open-loop setting that will reduce arterial pressure to a preselected set point and 2) a closed-loop mode that enables an adjustment to a dynamic pressure set point (i.e., the controlled pressure is reduced to a constant value below a reference pressure). A pneumatic servo-control mechanism was chosen to provide minimal control latency. The accuracy of the system under physiological conditions is well within +/- 1 mmHg. The device can be useful in a number of studies demanding a precise regulation of local arterial pressure, such as experiments on blood flow autoregulation, arterial baroreceptor reflexes, and all experiments involving the study of pressure-dependent excretory and incretory functions of the kidney. The closed-loop setting is useful for studying physiological feedback systems. 
700 1 |a Persson, Pontus B.  |e VerfasserIn  |0 (DE-588)1112496696  |0 (DE-627)866476806  |0 (DE-576)164907696  |4 aut 
700 1 |a Ehmke, Heimo  |e VerfasserIn  |0 (DE-588)1027511597  |0 (DE-627)729273695  |0 (DE-576)373290314  |4 aut 
700 1 |a Kirchheim, Hartmut  |d 1934-  |e VerfasserIn  |0 (DE-588)1018414541  |0 (DE-627)690601158  |0 (DE-576)355743469  |4 aut 
773 0 8 |i Enthalten in  |t American journal of physiology. Renal physiology  |d Bethesda, Md. : Soc., 1977  |g 262(1992), 2, Seite F320-F325  |h Online-Ressource  |w (DE-627)270426051  |w (DE-600)1477287-5  |w (DE-576)079718787  |x 1522-1466  |7 nnas  |a A servo-control system for open- and closed-loop blood pressure regulation 
773 1 8 |g volume:262  |g year:1992  |g number:2  |g pages:F320-F325  |g extent:6  |a A servo-control system for open- and closed-loop blood pressure regulation 
856 4 0 |u https://doi.org/10.1152/ajprenal.1992.262.2.F320  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.physiology.org/doi/abs/10.1152/ajprenal.1992.262.2.F320  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20241125 
993 |a Article 
994 |a 1992 
998 |g 1018414541  |a Kirchheim, Hartmut  |m 1018414541:Kirchheim, Hartmut  |d 50000  |d 53200  |e 50000PK1018414541  |e 53200PK1018414541  |k 0/50000/  |k 1/50000/53200/  |p 4  |y j 
998 |g 1027511597  |a Ehmke, Heimo  |m 1027511597:Ehmke, Heimo  |d 50000  |d 53200  |e 50000PE1027511597  |e 53200PE1027511597  |k 0/50000/  |k 1/50000/53200/  |p 3 
998 |g 1112496696  |a Persson, Pontus B.  |m 1112496696:Persson, Pontus B.  |d 50000  |d 53200  |e 50000PP1112496696  |e 53200PP1112496696  |k 0/50000/  |k 1/50000/53200/  |p 2 
999 |a KXP-PPN1909464678  |e 4622150344 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"recId":"1909464678","type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 25.11.2025"],"person":[{"roleDisplay":"VerfasserIn","display":"Nafz, Benno","role":"aut","family":"Nafz","given":"Benno"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Persson, Pontus B.","given":"Pontus B.","family":"Persson"},{"roleDisplay":"VerfasserIn","display":"Ehmke, Heimo","role":"aut","family":"Ehmke","given":"Heimo"},{"family":"Kirchheim","given":"Hartmut","display":"Kirchheim, Hartmut","roleDisplay":"VerfasserIn","role":"aut"}],"title":[{"title":"A servo-control system for open- and closed-loop blood pressure regulation","title_sort":"servo-control system for open- and closed-loop blood pressure regulation"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["1477287-5"],"eki":["270426051"],"issn":["1522-1466"]},"origin":[{"publisherPlace":"Bethesda, Md.","publisher":"Soc.","dateIssuedKey":"1977","dateIssuedDisp":"1977-"}],"name":{"displayForm":["publ. by the American Physiological Society"]},"part":{"text":"262(1992), 2, Seite F320-F325","volume":"262","extent":"6","year":"1992","pages":"F320-F325","issue":"2"},"titleAlt":[{"title":"American journal of physiology / Renal physiology"},{"title":"Renal, fluid and electrolyte physiology"}],"pubHistory":["232.1977 -"],"language":["eng"],"corporate":[{"display":"American Physiological Society","roleDisplay":"Herausgebendes Organ","role":"isb"}],"recId":"270426051","disp":"A servo-control system for open- and closed-loop blood pressure regulationAmerican journal of physiology. Renal physiology","type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 05.02.20"],"title":[{"title_sort":"American journal of physiology","title":"American journal of physiology","partname":"Renal physiology"}]}],"physDesc":[{"extent":"6 S."}],"name":{"displayForm":["B. Nafz, P.B. Persson, H. Ehmke, H.R. Kirchheim"]},"id":{"eki":["1909464678"],"doi":["10.1152/ajprenal.1992.262.2.F320"]},"origin":[{"dateIssuedKey":"1992","dateIssuedDisp":"February 1992"}]} 
SRT |a NAFZBENNOPSERVOCONTR1992