Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI

In this methodological paper the authors report the stereotactic correlation of different magnetic resonance imaging (MRI) techniques [MR-angiography (MRA), MRI, blood bolus tagging (STAR), and functional MRI] in 10 patients with ce rebral arteriovenous malformations (AVM) and its application in pre...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Schad, Lothar R. (VerfasserIn) , Bock, Michael (VerfasserIn) , Baudendistel, Klaus (VerfasserIn) , Essig, Marco (VerfasserIn) , Debus, Jürgen (VerfasserIn) , Knopp, Michael V. (VerfasserIn) , Engenhart, Rita (VerfasserIn) , Lorenz, W. J. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 1996
In: European radiology
Year: 1996, Jahrgang: 6, Heft: 1, Pages: 38-45
ISSN:1432-1084
DOI:10.1007/BF00619950
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/BF00619950
Volltext
Verfasserangaben:L R. Schad, M. Bock, K. Baudendistel, M. Essig, J. Debus, M.V. Knopp, R. Engenhart, W.J. Lorenz

MARC

LEADER 00000caa a2200000 c 4500
001 1912044439
003 DE-627
005 20250716215259.0
007 cr uuu---uuuuu
008 241211s1996 xx |||||o 00| ||eng c
024 7 |a 10.1007/BF00619950  |2 doi 
035 |a (DE-627)1912044439 
035 |a (DE-599)KXP1912044439 
035 |a (OCoLC)1528015184 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schad, Lothar R.  |d 1956-  |e VerfasserIn  |0 (DE-588)1028817630  |0 (DE-627)731640241  |0 (DE-576)376271221  |4 aut 
245 1 0 |a Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI  |c L R. Schad, M. Bock, K. Baudendistel, M. Essig, J. Debus, M.V. Knopp, R. Engenhart, W.J. Lorenz 
264 1 |c 1996 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 11.12.2024 
520 |a In this methodological paper the authors report the stereotactic correlation of different magnetic resonance imaging (MRI) techniques [MR-angiography (MRA), MRI, blood bolus tagging (STAR), and functional MRI] in 10 patients with ce rebral arteriovenous malformations (AVM) and its application in precision radiotherapy planning. The patient's head was fixed in a stereotactic localization system that is usable at the MR and the linear accelerator installations. Byphantom measurements different materials (steel, aluminium, titanium, plastic, wood, ceramics) used for the stereotactic system were tested for mechanical stability and geometrical MR image distortion. All metallic stereotactic rings (closed rings made of massive metal) led to a more or less dramatic geometrical distortion and signal cancellation in the MR images. The best properties —nearly no distortion and high mechanical stability are provided by a ceramic ring. If necessary, the re-maining geometrical MR image distortion can be “corrected” reducing displacements to the size of a pixel) by cal culations based on modelling the distortion as a fourth-order two-dimensional polynomial. Using this method multimodality matching can be performed automatically as long as all images are acquired ill the same examination and the patient is sufficiently immobilized. Precise definition ol the target volume could be performed by the radiotherapist either directly in MR images or in calculated projecon MR angiograms obtained by a maximum-intensity projection algorithm. As a result, information about the hemodynamics of the AVM was provided by a three-dimensional (3D) phase-contrast flow measurement and a dynamic MRA with the STAR technique leading to an improved definition of the size of the nidus, the origin of the feeding arteries, and the pattern of the venous drainage. In addition functional MRI was performed in patients wit lesions close to the primary motor cortex area leading to an improved definition of structures at risk for high-dose application in radiosurgery. The differnet imaging techniques of MR provide a sensitive, noninvasive, 3D method for de fining target volume, critical structures, and for calculating dose distributions for radiosurgery of cerebral arteriovenous malformations, because dose calculation of radiosurgery at sufficient accuracy can be based on 3D MR data of the geometrical conformation of the patient's head. 
650 4 |a Arteriovenous malformations 
650 4 |a Image correlation 
650 4 |a Magnetic resonance angiography 
650 4 |a Medical Imaging 
650 4 |a Radiosurgery 
700 1 |a Bock, Michael  |e VerfasserIn  |0 (DE-588)1140749323  |0 (DE-627)898660335  |0 (DE-576)494021470  |4 aut 
700 1 |a Baudendistel, Klaus  |e VerfasserIn  |0 (DE-588)1225704278  |0 (DE-627)1745589821  |4 aut 
700 1 |a Essig, Marco  |e VerfasserIn  |0 (DE-588)1048464490  |0 (DE-627)780470605  |0 (DE-576)172458595  |4 aut 
700 1 |a Debus, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1022671421  |0 (DE-627)717025780  |0 (DE-576)365774944  |4 aut 
700 1 |a Knopp, Michael V.  |e VerfasserIn  |0 (DE-588)1076637442  |0 (DE-627)835139344  |0 (DE-576)167521527  |4 aut 
700 1 |a Engenhart, Rita  |d 1953-  |e VerfasserIn  |0 (DE-588)173202926  |0 (DE-627)698123298  |0 (DE-576)134053044  |4 aut 
700 1 |a Lorenz, W. J.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t European radiology  |d Berlin : Springer, 1991  |g 6(1996), 1, Seite 38-45  |h Online-Ressource  |w (DE-627)268757526  |w (DE-600)1472718-3  |w (DE-576)103868070  |x 1432-1084  |7 nnas  |a Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI 
773 1 8 |g volume:6  |g year:1996  |g number:1  |g pages:38-45  |g extent:8  |a Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI 
856 4 0 |u https://doi.org/10.1007/BF00619950  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20241211 
993 |a Article 
994 |a 1996 
998 |g 173202926  |a Engenhart, Rita  |m 173202926:Engenhart, Rita  |d 50000  |e 50000PE173202926  |k 0/50000/  |p 7 
998 |g 1076637442  |a Knopp, Michael V.  |m 1076637442:Knopp, Michael V.  |d 50000  |e 50000PK1076637442  |k 0/50000/  |p 6 
998 |g 1022671421  |a Debus, Jürgen  |m 1022671421:Debus, Jürgen  |d 910000  |d 911400  |e 910000PD1022671421  |e 911400PD1022671421  |k 0/910000/  |k 1/910000/911400/  |p 5 
998 |g 1048464490  |a Essig, Marco  |m 1048464490:Essig, Marco  |d 50000  |e 50000PE1048464490  |k 0/50000/  |p 4 
998 |g 1225704278  |a Baudendistel, Klaus  |m 1225704278:Baudendistel, Klaus  |d 50000  |e 50000PB1225704278  |k 0/50000/  |p 3 
998 |g 1140749323  |a Bock, Michael  |m 1140749323:Bock, Michael  |d 910000  |d 911400  |e 910000PB1140749323  |e 911400PB1140749323  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 1028817630  |a Schad, Lothar R.  |m 1028817630:Schad, Lothar R.  |d 60000  |e 60000PS1028817630  |k 0/60000/  |p 1  |x j 
999 |a KXP-PPN1912044439  |e 4634684896 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1912044439","physDesc":[{"extent":"8 S."}],"title":[{"title_sort":"Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI","title":"Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI"}],"note":["Gesehen am 11.12.2024"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"relHost":[{"origin":[{"dateIssuedKey":"1991","dateIssuedDisp":"1991-","publisherPlace":"Berlin ; Heidelberg","publisher":"Springer"}],"title":[{"title_sort":"European radiology","title":"European radiology","subtitle":"official organ of the European Association of Radiology"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"note":["Gesehen am 06.02.2018","Ungezählte Beil.: Supplement"],"recId":"268757526","physDesc":[{"extent":"Online-Ressource"}],"disp":"Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRIEuropean radiology","pubHistory":["1.1991 -"],"titleAlt":[{"title":"European radiology / Supplement"},{"title":"European radiology supplements"}],"corporate":[{"role":"isb","display":"European Association of Radiology"}],"id":{"zdb":["1472718-3"],"issn":["1432-1084","1613-3757"],"eki":["268757526"]},"part":{"text":"6(1996), 1, Seite 38-45","extent":"8","issue":"1","pages":"38-45","volume":"6","year":"1996"}}],"person":[{"role":"aut","given":"Lothar R.","family":"Schad","display":"Schad, Lothar R."},{"family":"Bock","role":"aut","given":"Michael","display":"Bock, Michael"},{"role":"aut","given":"Klaus","family":"Baudendistel","display":"Baudendistel, Klaus"},{"display":"Essig, Marco","family":"Essig","role":"aut","given":"Marco"},{"given":"Jürgen","role":"aut","family":"Debus","display":"Debus, Jürgen"},{"display":"Knopp, Michael V.","given":"Michael V.","role":"aut","family":"Knopp"},{"display":"Engenhart, Rita","family":"Engenhart","given":"Rita","role":"aut"},{"family":"Lorenz","given":"W. J.","role":"aut","display":"Lorenz, W. J."}],"origin":[{"dateIssuedKey":"1996","dateIssuedDisp":"1996"}],"id":{"eki":["1912044439"],"doi":["10.1007/BF00619950"]},"name":{"displayForm":["L R. Schad, M. Bock, K. Baudendistel, M. Essig, J. Debus, M.V. Knopp, R. Engenhart, W.J. Lorenz"]}} 
SRT |a SCHADLOTHAIMPROVEDTA1996