Comparison of automated kidney stone size measurement and volumetry in photon counting CT compared to 3rd generation dual energy CT and physically measurements: an ex vivo study

Purpose  This ex vivo study aimed to compare a newly developed dual-source photon-counting CT (PCCT) with a 3rd generation dual-source dual-energy CT (DECT) for the detection and measurement (stone lengths and volumetrics) of urinary stones. - Methods  143 urinary stones with a known geometry were p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Nestler, Tim (VerfasserIn) , Stoll, Rico (VerfasserIn) , Schmelz, Hans (VerfasserIn) , Schoch, Justine (VerfasserIn) , Hesse, Albrecht (VerfasserIn) , Nestler, Kai (VerfasserIn) , Smolka, Kerstin (VerfasserIn) , Faby, Sebastian (VerfasserIn) , Jürgens, Markus (VerfasserIn) , Schmidt, Bernhard (VerfasserIn) , Spornitz, Katja (VerfasserIn) , Overhoff, Daniel (VerfasserIn) , Waldeck, Stephan (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 22 July 2024
In: World journal of urology
Year: 2024, Jahrgang: 42, Heft: 1, Pages: 1-7
ISSN:1433-8726
DOI:10.1007/s00345-024-05114-x
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s00345-024-05114-x
Verlag, lizenzpflichtig, Volltext: https://link.springer.com/10.1007/s00345-024-05114-x
Volltext
Verfasserangaben:Tim Nestler, Rico Stoll, Hans Schmelz, Justine Schoch, Albrecht Hesse, Kai Nestler, Kerstin Smolka, Sebastian Faby, Markus Jürgens, Bernhard Schmidt, Katja Spornitz, Daniel Overhoff, Stephan Waldeck

MARC

LEADER 00000caa a2200000 c 4500
001 1914500903
003 DE-627
005 20250716222008.0
007 cr uuu---uuuuu
008 250113s2024 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00345-024-05114-x  |2 doi 
035 |a (DE-627)1914500903 
035 |a (DE-599)KXP1914500903 
035 |a (OCoLC)1528016047 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Nestler, Tim  |e VerfasserIn  |0 (DE-588)1229721606  |0 (DE-627)175187883X  |4 aut 
245 1 0 |a Comparison of automated kidney stone size measurement and volumetry in photon counting CT compared to 3rd generation dual energy CT and physically measurements  |b an ex vivo study  |c Tim Nestler, Rico Stoll, Hans Schmelz, Justine Schoch, Albrecht Hesse, Kai Nestler, Kerstin Smolka, Sebastian Faby, Markus Jürgens, Bernhard Schmidt, Katja Spornitz, Daniel Overhoff, Stephan Waldeck 
264 1 |c 22 July 2024 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 13.01.2025 
520 |a Purpose  This ex vivo study aimed to compare a newly developed dual-source photon-counting CT (PCCT) with a 3rd generation dual-source dual-energy CT (DECT) for the detection and measurement (stone lengths and volumetrics) of urinary stones. - Methods  143 urinary stones with a known geometry were physically measured and defined as reference values. Next, urinary stones were placed in an anthropomorphic abdomen-model and were scanned with DECT and PCCT. Images were read by two experienced examiners and automatically evaluated using a specific software. - Results  DECT and PCCT showed a high sensitivity for manual stone detection of 97.9% and 94.4%, and for automatic detection of 93.0% and 87.4%, respectively. Compared to that uric acid and xanthine stones were recognized slightly worse by DECT and PCCT with manual stone detection (93.3% and 82.2%), and with automatic detection (77.8% and 60.0%). All other stone entities were completely recognized. By comparing the maximum diameter of the reference value and DECT, Pearson-correlation was 0.96 (p < 0.001) for manual and 0.97 (p < 0.001) for automatic measurement, and for PCCT it was 0.94 (p < 0.001) for manual and 0.97 (p < 0.001) for automatic measurements. DECT and PCCT can also reliably determine volume manually and automatically with a Pearson-correlation of 0.99 (p < 0.001), respectively. - Conclusion  Both CTs showed comparable results in stone detection, length measurement and volumetry compared to the reference values. Automatic measurement tends to underestimate the maximum diameter. DECT proved to be slightly superior in the recognition of xanthine and uric acid stones. 
700 1 |a Stoll, Rico  |e VerfasserIn  |4 aut 
700 1 |a Schmelz, Hans  |e VerfasserIn  |4 aut 
700 1 |a Schoch, Justine  |e VerfasserIn  |4 aut 
700 1 |a Hesse, Albrecht  |e VerfasserIn  |4 aut 
700 1 |a Nestler, Kai  |e VerfasserIn  |0 (DE-588)1081965606  |0 (DE-627)846931966  |0 (DE-576)455008175  |4 aut 
700 1 |a Smolka, Kerstin  |d 1974-  |e VerfasserIn  |0 (DE-588)136947921  |0 (DE-627)589451642  |0 (DE-576)301505500  |4 aut 
700 1 |a Faby, Sebastian  |e VerfasserIn  |4 aut 
700 1 |a Jürgens, Markus  |e VerfasserIn  |4 aut 
700 1 |a Schmidt, Bernhard  |e VerfasserIn  |4 aut 
700 1 |a Spornitz, Katja  |e VerfasserIn  |4 aut 
700 1 |a Overhoff, Daniel  |d 1984-  |e VerfasserIn  |0 (DE-588)1098192257  |0 (DE-627)85747944X  |0 (DE-576)469013397  |4 aut 
700 1 |a Waldeck, Stephan  |e VerfasserIn  |0 (DE-588)1285323718  |0 (DE-627)184121423X  |0 (DE-576)134501519  |4 aut 
773 0 8 |i Enthalten in  |t World journal of urology  |d Berlin : Springer, 1983  |g 42(2024), 1, Artikel-ID 433, Seite 1-7  |h Online-Ressource  |w (DE-627)254910874  |w (DE-600)1463303-6  |w (DE-576)074754505  |x 1433-8726  |7 nnas  |a Comparison of automated kidney stone size measurement and volumetry in photon counting CT compared to 3rd generation dual energy CT and physically measurements an ex vivo study 
773 1 8 |g volume:42  |g year:2024  |g number:1  |g elocationid:433  |g pages:1-7  |g extent:7  |a Comparison of automated kidney stone size measurement and volumetry in photon counting CT compared to 3rd generation dual energy CT and physically measurements an ex vivo study 
856 4 0 |u https://doi.org/10.1007/s00345-024-05114-x  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://link.springer.com/10.1007/s00345-024-05114-x  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20250113 
993 |a Article 
994 |a 2024 
998 |g 1098192257  |a Overhoff, Daniel  |m 1098192257:Overhoff, Daniel  |d 60000  |d 62900  |e 60000PO1098192257  |e 62900PO1098192257  |k 0/60000/  |k 1/60000/62900/  |p 12 
999 |a KXP-PPN1914500903  |e 4650890004 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"22 July 2024"}],"id":{"doi":["10.1007/s00345-024-05114-x"],"eki":["1914500903"]},"name":{"displayForm":["Tim Nestler, Rico Stoll, Hans Schmelz, Justine Schoch, Albrecht Hesse, Kai Nestler, Kerstin Smolka, Sebastian Faby, Markus Jürgens, Bernhard Schmidt, Katja Spornitz, Daniel Overhoff, Stephan Waldeck"]},"physDesc":[{"extent":"7 S."}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["1433-8726"],"eki":["254910874"],"zdb":["1463303-6"]},"origin":[{"dateIssuedKey":"1983","publisher":"Springer","dateIssuedDisp":"1983-","publisherPlace":"Berlin ; Heidelberg"}],"recId":"254910874","language":["eng"],"disp":"Comparison of automated kidney stone size measurement and volumetry in photon counting CT compared to 3rd generation dual energy CT and physically measurements an ex vivo studyWorld journal of urology","type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 06.12.05","Teils ungezählte Beil.: Supplement"],"part":{"issue":"1","pages":"1-7","year":"2024","extent":"7","text":"42(2024), 1, Artikel-ID 433, Seite 1-7","volume":"42"},"pubHistory":["1.1983 -"],"title":[{"title":"World journal of urology","title_sort":"World journal of urology"}]}],"title":[{"subtitle":"an ex vivo study","title":"Comparison of automated kidney stone size measurement and volumetry in photon counting CT compared to 3rd generation dual energy CT and physically measurements","title_sort":"Comparison of automated kidney stone size measurement and volumetry in photon counting CT compared to 3rd generation dual energy CT and physically measurements"}],"person":[{"roleDisplay":"VerfasserIn","display":"Nestler, Tim","role":"aut","family":"Nestler","given":"Tim"},{"role":"aut","display":"Stoll, Rico","roleDisplay":"VerfasserIn","given":"Rico","family":"Stoll"},{"given":"Hans","family":"Schmelz","role":"aut","roleDisplay":"VerfasserIn","display":"Schmelz, Hans"},{"display":"Schoch, Justine","roleDisplay":"VerfasserIn","role":"aut","family":"Schoch","given":"Justine"},{"display":"Hesse, Albrecht","roleDisplay":"VerfasserIn","role":"aut","family":"Hesse","given":"Albrecht"},{"role":"aut","display":"Nestler, Kai","roleDisplay":"VerfasserIn","given":"Kai","family":"Nestler"},{"given":"Kerstin","family":"Smolka","role":"aut","roleDisplay":"VerfasserIn","display":"Smolka, Kerstin"},{"family":"Faby","given":"Sebastian","roleDisplay":"VerfasserIn","display":"Faby, Sebastian","role":"aut"},{"family":"Jürgens","given":"Markus","roleDisplay":"VerfasserIn","display":"Jürgens, Markus","role":"aut"},{"display":"Schmidt, Bernhard","roleDisplay":"VerfasserIn","role":"aut","family":"Schmidt","given":"Bernhard"},{"role":"aut","display":"Spornitz, Katja","roleDisplay":"VerfasserIn","given":"Katja","family":"Spornitz"},{"role":"aut","display":"Overhoff, Daniel","roleDisplay":"VerfasserIn","given":"Daniel","family":"Overhoff"},{"roleDisplay":"VerfasserIn","display":"Waldeck, Stephan","role":"aut","family":"Waldeck","given":"Stephan"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 13.01.2025"],"recId":"1914500903","language":["eng"]} 
SRT |a NESTLERTIMCOMPARISON2220