Ultra-low-dose photon-counting CT of paranasal sinus: an in vivo comparison of radiation dose and image quality to cone-beam CT
This study investigated the differences in subjective and objective image parameters as well as dose exposure of photon-counting CT (PCCT) compared to cone-beam CT (CBCT) in paranasal sinus imaging for the assessment of rhinosinusitis and sinonasal anatomy.This single-centre retrospective study incl...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
February 2024
|
| In: |
Dentomaxillofacial radiology
Year: 2024, Jahrgang: 53, Heft: 2, Pages: 103-108 |
| ISSN: | 1476-542X |
| DOI: | 10.1093/dmfr/twad010 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1093/dmfr/twad010 |
| Verfasserangaben: | Hanns Leonhard Kaatsch, MD, Florian Fulisch, MD, Daniel Dillinger, MD, Laura Kubitscheck, MD, Benjamin V. Becker, MD, Joel Piechotka, MSc, Marc A. Brockmann, MSc, Matthias F. Froelich, MD, Stefan O. Schoenberg, MD, Daniel Overhoff, Stephan Waldeck, MD |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1914630076 | ||
| 003 | DE-627 | ||
| 005 | 20250716222435.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 250115s2024 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1093/dmfr/twad010 |2 doi | |
| 035 | |a (DE-627)1914630076 | ||
| 035 | |a (DE-599)KXP1914630076 | ||
| 035 | |a (OCoLC)1528016354 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Kaatsch, Hanns Leonhard |e VerfasserIn |0 (DE-588)1353414620 |0 (DE-627)1914630505 |4 aut | |
| 245 | 1 | 0 | |a Ultra-low-dose photon-counting CT of paranasal sinus |b an in vivo comparison of radiation dose and image quality to cone-beam CT |c Hanns Leonhard Kaatsch, MD, Florian Fulisch, MD, Daniel Dillinger, MD, Laura Kubitscheck, MD, Benjamin V. Becker, MD, Joel Piechotka, MSc, Marc A. Brockmann, MSc, Matthias F. Froelich, MD, Stefan O. Schoenberg, MD, Daniel Overhoff, Stephan Waldeck, MD |
| 264 | 1 | |c February 2024 | |
| 300 | |b Illustrationen | ||
| 300 | |a 6 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Online veröffentlicht: 13. Dezember 2023 | ||
| 500 | |a Gesehen am 15.01.2025 | ||
| 520 | |a This study investigated the differences in subjective and objective image parameters as well as dose exposure of photon-counting CT (PCCT) compared to cone-beam CT (CBCT) in paranasal sinus imaging for the assessment of rhinosinusitis and sinonasal anatomy.This single-centre retrospective study included 100 patients, who underwent either clinically indicated PCCT or CBCT of the paranasal sinus. Two blinded experienced ENT radiologists graded image quality and delineation of specific anatomical structures on a 5-point Likert scale. In addition, contrast-to-noise ratio (CNR) and applied radiation doses were compared among both techniques.Image quality and delineation of bone structures in paranasal sinus PCCT was subjectively rated superior by both readers compared to CBCT (P < .001). CNR was significantly higher for photon-counting CT (P < .001). Mean effective dose for PCCT examinations was significantly lower than for CBCT (0.038 mSv ± 0.009 vs. 0.14 mSv ± 0.011; P < .001).In a performance comparison of PCCT and a modern CBCT scanner in paranasal sinus imaging, we demonstrated that first-use PCCT in clinical routine provides higher subjective image quality accompanied by higher CNR at close to a quarter of the dose exposure compared to CBCT. | ||
| 700 | 1 | |a Fulisch, Florian |e VerfasserIn |4 aut | |
| 700 | 1 | |a Dillinger, Daniel |e VerfasserIn |4 aut | |
| 700 | 1 | |a Kubitscheck, Laura |e VerfasserIn |4 aut | |
| 700 | 1 | |a Becker, Benjamin V |e VerfasserIn |4 aut | |
| 700 | 1 | |a Piechotka, Joel |e VerfasserIn |4 aut | |
| 700 | 1 | |a Brockmann, Marc A |e VerfasserIn |4 aut | |
| 700 | 1 | |a Froelich, Matthias F. |d 1991- |e VerfasserIn |0 (DE-588)1170833756 |0 (DE-627)1040131557 |0 (DE-576)512678359 |4 aut | |
| 700 | 1 | |a Schönberg, Stefan |d 1969- |e VerfasserIn |0 (DE-588)131557912 |0 (DE-627)510700624 |0 (DE-576)298584891 |4 aut | |
| 700 | 1 | |a Overhoff, Daniel |d 1984- |e VerfasserIn |0 (DE-588)1098192257 |0 (DE-627)85747944X |0 (DE-576)469013397 |4 aut | |
| 700 | 1 | |a Waldeck, Stephan |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Dentomaxillofacial radiology |d [Oxford] : Oxford University Press, 1972 |g 53(2024), 2 vom: Feb., Seite 103-108 |h Online-Ressource |w (DE-627)320440737 |w (DE-600)2004893-2 |w (DE-576)113246420 |x 1476-542X |7 nnas |a Ultra-low-dose photon-counting CT of paranasal sinus an in vivo comparison of radiation dose and image quality to cone-beam CT |
| 773 | 1 | 8 | |g volume:53 |g year:2024 |g number:2 |g month:02 |g pages:103-108 |g extent:6 |a Ultra-low-dose photon-counting CT of paranasal sinus an in vivo comparison of radiation dose and image quality to cone-beam CT |
| 856 | 4 | 0 | |u https://doi.org/10.1093/dmfr/twad010 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20250115 | ||
| 993 | |a Article | ||
| 994 | |a 2024 | ||
| 998 | |g 1098192257 |a Overhoff, Daniel |m 1098192257:Overhoff, Daniel |d 60000 |d 62900 |e 60000PO1098192257 |e 62900PO1098192257 |k 0/60000/ |k 1/60000/62900/ |p 10 | ||
| 998 | |g 131557912 |a Schönberg, Stefan |m 131557912:Schönberg, Stefan |d 60000 |d 62900 |e 60000PS131557912 |e 62900PS131557912 |k 0/60000/ |k 1/60000/62900/ |p 9 | ||
| 998 | |g 1170833756 |a Froelich, Matthias F. |m 1170833756:Froelich, Matthias F. |d 60000 |d 62900 |d 60000 |d 61800 |e 60000PF1170833756 |e 62900PF1170833756 |e 60000PF1170833756 |e 61800PF1170833756 |k 0/60000/ |k 1/60000/62900/ |k 0/60000/ |k 1/60000/61800/ |p 8 | ||
| 999 | |a KXP-PPN1914630076 |e 4651821162 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"person":[{"given":"Hanns Leonhard","display":"Kaatsch, Hanns Leonhard","role":"aut","roleDisplay":"VerfasserIn","family":"Kaatsch"},{"display":"Fulisch, Florian","role":"aut","given":"Florian","roleDisplay":"VerfasserIn","family":"Fulisch"},{"family":"Dillinger","roleDisplay":"VerfasserIn","display":"Dillinger, Daniel","role":"aut","given":"Daniel"},{"roleDisplay":"VerfasserIn","family":"Kubitscheck","given":"Laura","display":"Kubitscheck, Laura","role":"aut"},{"roleDisplay":"VerfasserIn","family":"Becker","given":"Benjamin V","role":"aut","display":"Becker, Benjamin V"},{"given":"Joel","display":"Piechotka, Joel","role":"aut","roleDisplay":"VerfasserIn","family":"Piechotka"},{"roleDisplay":"VerfasserIn","family":"Brockmann","role":"aut","display":"Brockmann, Marc A","given":"Marc A"},{"roleDisplay":"VerfasserIn","family":"Froelich","role":"aut","display":"Froelich, Matthias F.","given":"Matthias F."},{"role":"aut","display":"Schönberg, Stefan","given":"Stefan","family":"Schönberg","roleDisplay":"VerfasserIn"},{"family":"Overhoff","roleDisplay":"VerfasserIn","role":"aut","display":"Overhoff, Daniel","given":"Daniel"},{"given":"Stephan","display":"Waldeck, Stephan","role":"aut","family":"Waldeck","roleDisplay":"VerfasserIn"}],"physDesc":[{"noteIll":"Illustrationen","extent":"6 S."}],"name":{"displayForm":["Hanns Leonhard Kaatsch, MD, Florian Fulisch, MD, Daniel Dillinger, MD, Laura Kubitscheck, MD, Benjamin V. Becker, MD, Joel Piechotka, MSc, Marc A. Brockmann, MSc, Matthias F. Froelich, MD, Stefan O. Schoenberg, MD, Daniel Overhoff, Stephan Waldeck, MD"]},"relHost":[{"recId":"320440737","pubHistory":["1.1972 -"],"titleAlt":[{"title":"journal of the International Association of Dentomaxillofacial Radiology"},{"title":"DMFR"}],"corporate":[{"display":"International Association of Dentomaxillofacial Radiology","role":"isb","roleDisplay":"Herausgebendes Organ"}],"language":["eng"],"origin":[{"dateIssuedKey":"1972","publisherPlace":"[Oxford] ; [Erscheinungsort nicht ermittelbar] ; London ; Hoboken, NJ","dateIssuedDisp":"1972-","publisher":"Oxford University Press ; Nature Publ. Group ; British Institute of Radiology ; Wiley"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"part":{"pages":"103-108","year":"2024","extent":"6","volume":"53","issue":"2","text":"53(2024), 2 vom: Feb., Seite 103-108"},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"subtitle":"DMFR : a journal of head and neck imaging","title":"Dentomaxillofacial radiology","title_sort":"Dentomaxillofacial radiology"}],"id":{"eki":["320440737"],"zdb":["2004893-2"],"issn":["1476-542X"]},"note":["Gesehen am 10.07.24"],"disp":"Ultra-low-dose photon-counting CT of paranasal sinus an in vivo comparison of radiation dose and image quality to cone-beam CTDentomaxillofacial radiology"}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"February 2024"}],"title":[{"title":"Ultra-low-dose photon-counting CT of paranasal sinus","title_sort":"Ultra-low-dose photon-counting CT of paranasal sinus","subtitle":"an in vivo comparison of radiation dose and image quality to cone-beam CT"}],"id":{"eki":["1914630076"],"doi":["10.1093/dmfr/twad010"]},"recId":"1914630076","note":["Online veröffentlicht: 13. Dezember 2023","Gesehen am 15.01.2025"]} | ||
| SRT | |a KAATSCHHANULTRALOWDO2024 | ||