Spectral performance evaluation of a second-generation spectral detector CT
Purpose The aim of this study was to characterize a second-generation wide-detector dual-layer spectral computed tomography (CT) system for material quantification accuracy, acquisition parameter and patient size dependencies, and tissue characterization capabilities. Methods A phantom with multiple...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
April 2024
|
| In: |
Journal of applied clinical medical physics
Year: 2024, Jahrgang: 25, Heft: 4, Pages: e14300-1-e14300-13 |
| ISSN: | 1526-9914 |
| DOI: | 10.1002/acm2.14300 |
| Online-Zugang: | Verlag, kostenfrei, Volltext: https://doi.org/10.1002/acm2.14300 Verlag, kostenfrei, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/acm2.14300 |
| Verfasserangaben: | Leening P. Liu, Nadav Shapira, Sandra S. Halliburton, Sebastian Meyer, Amy Perkins, Harold I. Litt, Hans Ulrich Kauczor, Tim Leiner, Wolfram Stiller, Peter B. Noël |
MARC
| LEADER | 00000naa a2200000 4500 | ||
|---|---|---|---|
| 001 | 1917508700 | ||
| 003 | DE-627 | ||
| 005 | 20250218160930.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 250218s2024 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1002/acm2.14300 |2 doi | |
| 035 | |a (DE-627)1917508700 | ||
| 035 | |a (DE-599)KXP1917508700 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Liu, Leening P. |e VerfasserIn |0 (DE-588)1356735711 |0 (DE-627)1917510039 |4 aut | |
| 245 | 1 | 0 | |a Spectral performance evaluation of a second-generation spectral detector CT |c Leening P. Liu, Nadav Shapira, Sandra S. Halliburton, Sebastian Meyer, Amy Perkins, Harold I. Litt, Hans Ulrich Kauczor, Tim Leiner, Wolfram Stiller, Peter B. Noël |
| 264 | 1 | |c April 2024 | |
| 300 | |b Illustrationen | ||
| 300 | |a 13 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 18.02.2025 | ||
| 520 | |a Purpose The aim of this study was to characterize a second-generation wide-detector dual-layer spectral computed tomography (CT) system for material quantification accuracy, acquisition parameter and patient size dependencies, and tissue characterization capabilities. Methods A phantom with multiple tissue-mimicking and material-specific inserts was scanned with a dual-layer spectral detector CT using different tube voltages, collimation widths, radiation dose levels, and size configurations. Accuracy of iodine density maps and virtual monoenergetic images (MonoE) were investigated. Additionally, differences between conventional and MonoE 70 keV images were calculated to evaluate acquisition parameter and patient size dependencies. To demonstrate material quantification and differentiation, liver-mimicking inserts with adipose and iron were analyzed with a two-base decomposition utilizing MonoE 50 and 150 keV, and root mean square error (RMSE) for adipose and iron content was reported. Results Measured inserts exhibited quantitative accuracy across a wide range of MonoE levels. MonoE 70 keV images demonstrated reduced dependence compared to conventional images for phantom size (1 vs. 27 HU) and acquisition parameters, particularly tube voltage (4 vs. 37 HU). Iodine density quantification was successful with errors ranging from -0.58 to 0.44 mg/mL. Similarly, inserts with different amounts of adipose and iron were differentiated, and the small deviation in values within inserts corresponded to a RMSE of 3.49 ± 1.76% and 1.67 ± 0.84 mg/mL for adipose and iron content, respectively. Conclusion The second-generation dual-layer CT enables acquisition of quantitatively accurate spectral data without compromises from differences in patient size and acquisition parameters. | ||
| 650 | 4 | |a dual energy CT | |
| 650 | 4 | |a spectral CT | |
| 700 | 1 | |a Shapira, Nadav |e VerfasserIn |4 aut | |
| 700 | 1 | |a Halliburton, Sandra S. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Meyer, Sebastian |e VerfasserIn |4 aut | |
| 700 | 1 | |a Perkins, Amy |e VerfasserIn |4 aut | |
| 700 | 1 | |a Litt, Harold I. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Kauczor, Hans-Ulrich |d 1962- |e VerfasserIn |0 (DE-588)139267123 |0 (DE-627)70327113X |0 (DE-576)310955327 |4 aut | |
| 700 | 1 | |a Leiner, Tim |e VerfasserIn |4 aut | |
| 700 | 1 | |a Stiller, Wolfram |d 1976- |e VerfasserIn |0 (DE-588)105822672X |0 (DE-627)796627495 |0 (DE-576)414249496 |4 aut | |
| 700 | 1 | |a Noël, Peter B. |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of applied clinical medical physics |d Reston, Va. : ACMP, 2000 |g 25(2024), 4 vom: Apr., Artikel-ID e14300, Seite e14300-1-e14300-13 |h Online-Ressource |w (DE-627)312202091 |w (DE-600)2010347-5 |w (DE-576)281192669 |x 1526-9914 |7 nnns |a Spectral performance evaluation of a second-generation spectral detector CT |
| 773 | 1 | 8 | |g volume:25 |g year:2024 |g number:4 |g month:04 |g elocationid:e14300 |g pages:e14300-1-e14300-13 |g extent:13 |a Spectral performance evaluation of a second-generation spectral detector CT |
| 856 | 4 | 0 | |u https://doi.org/10.1002/acm2.14300 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://onlinelibrary.wiley.com/doi/abs/10.1002/acm2.14300 |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20250218 | ||
| 993 | |a Article | ||
| 994 | |a 2024 | ||
| 998 | |g 105822672X |a Stiller, Wolfram |m 105822672X:Stiller, Wolfram |d 910000 |d 911400 |d 50000 |e 910000PS105822672X |e 911400PS105822672X |e 50000PS105822672X |k 0/910000/ |k 1/910000/911400/ |k 0/50000/ |p 9 | ||
| 998 | |g 139267123 |a Kauczor, Hans-Ulrich |m 139267123:Kauczor, Hans-Ulrich |d 910000 |d 911400 |e 910000PK139267123 |e 911400PK139267123 |k 0/910000/ |k 1/910000/911400/ |p 7 | ||
| 999 | |a KXP-PPN1917508700 |e 4666056424 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"disp":"Spectral performance evaluation of a second-generation spectral detector CTJournal of applied clinical medical physics","physDesc":[{"extent":"Online-Ressource"}],"name":{"displayForm":["American College of Medical Physics"]},"pubHistory":["1.2000 -"],"origin":[{"publisher":"ACMP","dateIssuedDisp":"2000-","dateIssuedKey":"2000","publisherPlace":"Reston, Va."}],"part":{"text":"25(2024), 4 vom: Apr., Artikel-ID e14300, Seite e14300-1-e14300-13","extent":"13","year":"2024","issue":"4","volume":"25","pages":"e14300-1-e14300-13"},"recId":"312202091","id":{"issn":["1526-9914"],"zdb":["2010347-5"],"eki":["312202091"]},"note":["Gesehen am 17. Januar 2017"],"title":[{"title_sort":"Journal of applied clinical medical physics","title":"Journal of applied clinical medical physics"}]}],"id":{"doi":["10.1002/acm2.14300"],"eki":["1917508700"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"recId":"1917508700","origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"April 2024"}],"title":[{"title_sort":"Spectral performance evaluation of a second-generation spectral detector CT","title":"Spectral performance evaluation of a second-generation spectral detector CT"}],"name":{"displayForm":["Leening P. Liu, Nadav Shapira, Sandra S. Halliburton, Sebastian Meyer, Amy Perkins, Harold I. Litt, Hans Ulrich Kauczor, Tim Leiner, Wolfram Stiller, Peter B. Noël"]},"physDesc":[{"noteIll":"Illustrationen","extent":"S.13"}],"person":[{"roleDisplay":"VerfasserIn","given":"Leening P.","family":"Liu","display":"Liu, Leening P.","role":"aut"},{"role":"aut","display":"Shapira, Nadav","family":"Shapira","given":"Nadav","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","given":"Sandra S.","family":"Halliburton","role":"aut","display":"Halliburton, Sandra S."},{"role":"aut","display":"Meyer, Sebastian","family":"Meyer","given":"Sebastian","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","given":"Amy","family":"Perkins","display":"Perkins, Amy","role":"aut"},{"given":"Harold I.","roleDisplay":"VerfasserIn","role":"aut","display":"Litt, Harold I.","family":"Litt"},{"display":"Kauczor, Hans-Ulrich","role":"aut","family":"Kauczor","given":"Hans-Ulrich","roleDisplay":"VerfasserIn"},{"given":"Tim","roleDisplay":"VerfasserIn","role":"aut","display":"Leiner, Tim","family":"Leiner"},{"given":"Wolfram","roleDisplay":"VerfasserIn","display":"Stiller, Wolfram","role":"aut","family":"Stiller"},{"display":"Noël, Peter B.","role":"aut","family":"Noël","given":"Peter B.","roleDisplay":"VerfasserIn"}],"language":["eng"],"note":["Gesehen am 18.02.2025"]} | ||
| SRT | |a LIULEENINGSPECTRALPE2024 | ||