Online MR-guided proton and ion beam radiotherapy: investigation of image quality

Objective. Magnetic resonance (MR) images free of artefacts are of pivotal importance for MR-guided ion radiotherapy. This study investigates MR image quality for simultaneous irradiation in an experimental setup using phantom imaging as well as in-vivo imaging. Observed artefacts are described with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Paul, Katharina (VerfasserIn) , Dorsch, Stefan (VerfasserIn) , Elter, Alina (VerfasserIn) , Beyer, Cedric (VerfasserIn) , Naumann, Jakob (VerfasserIn) , Hansmann, Tim (VerfasserIn) , Feldmeier, Elisabeth (VerfasserIn) , Haberer, Thomas (VerfasserIn) , Karger, Christian (VerfasserIn) , Debus, Jürgen (VerfasserIn) , Klüter, Sebastian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 13 September 2024
In: Physics in medicine and biology
Year: 2024, Jahrgang: 69, Heft: 18, Pages: 1-14
ISSN:1361-6560
DOI:10.1088/1361-6560/ad7453
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1088/1361-6560/ad7453
Verlag, kostenfrei, Volltext: https://dx.doi.org/10.1088/1361-6560/ad7453
Volltext
Verfasserangaben:K Paul, S Dorsch, A Elter, C Beyer, J Naumann, T Hansmann, E Feldmeier, T Haberer, C P Karger, J Debus and S Klüter

MARC

LEADER 00000caa a2200000 c 4500
001 1918898766
003 DE-627
005 20250716234844.0
007 cr uuu---uuuuu
008 250303s2024 xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/ad7453  |2 doi 
035 |a (DE-627)1918898766 
035 |a (DE-599)KXP1918898766 
035 |a (OCoLC)1528019902 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Paul, Katharina  |e VerfasserIn  |0 (DE-588)1079849041  |0 (DE-627)842377573  |0 (DE-576)453053793  |4 aut 
245 1 0 |a Online MR-guided proton and ion beam radiotherapy  |b investigation of image quality  |c K Paul, S Dorsch, A Elter, C Beyer, J Naumann, T Hansmann, E Feldmeier, T Haberer, C P Karger, J Debus and S Klüter 
264 1 |c 13 September 2024 
300 |b Illustrationen 
300 |a 14 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 03.03.2025 
520 |a Objective. Magnetic resonance (MR) images free of artefacts are of pivotal importance for MR-guided ion radiotherapy. This study investigates MR image quality for simultaneous irradiation in an experimental setup using phantom imaging as well as in-vivo imaging. Observed artefacts are described within the study and their cause is investigated with the goal to find conclusions and solutions for potential future hybrid devices. Approach. An open MR scanner with a field strength of 0.25 T has been installed in front of an ion beamline. Simultaneous magnetic resonance imaging and irradiation using raster scanning were performed to analyze image quality in dedicated phantoms. Magnetic field measurements were performed to assist the explanation of observed artifacts. In addition, in-vivo images were acquired by operating the magnets for beam scanning without transporting a beam. Main Results. The additional frequency component within the isocenter caused by the fringe field of the horizontal beam scanning magnet correlates with the amplitude and frequency of the scanning magnet steering and can cause ghosting artifacts in the images. These are amplified with high currents and fast operating of the scanning magnet. Applying a real-time capable pulse sequence in-vivo revealed no ghosting artifacts despite a continuously changing current pattern and a clinical treatment plan activation scheme, suggesting that the use of fast imaging is beneficial for the aim of creating high quality in-beam MR images. This result suggests, that the influence of the scanning magnets on the MR acquisition might be of negligible importance and does not need further measures like extensive magnetic shielding of the scanning magnets. Significance. Our study delimited artefacts observed in MR images acquired during simultaneous raster scanning ion beam irradiation. The application of a fast pulse sequence showed no image artefacts and holds the potential that online MR imaging in future hybrid devices might be feasible. 
700 1 |a Dorsch, Stefan  |d 1989-  |e VerfasserIn  |0 (DE-588)1187162752  |0 (DE-627)1666316008  |4 aut 
700 1 |a Elter, Alina  |d 1994-  |e VerfasserIn  |0 (DE-588)1199970298  |0 (DE-627)1682114309  |4 aut 
700 1 |a Beyer, Cedric  |e VerfasserIn  |0 (DE-588)135843087X  |0 (DE-627)1918903999  |4 aut 
700 1 |a Naumann, Jakob  |d 1969-  |e VerfasserIn  |0 (DE-588)123702291  |0 (DE-627)706401565  |0 (DE-576)293834199  |4 aut 
700 1 |a Hansmann, Tim  |e VerfasserIn  |4 aut 
700 1 |a Feldmeier, Elisabeth  |e VerfasserIn  |4 aut 
700 1 |a Haberer, Thomas  |d 1960-  |e VerfasserIn  |0 (DE-588)123579198  |0 (DE-627)706353714  |0 (DE-576)214902188  |4 aut 
700 1 |a Karger, Christian  |e VerfasserIn  |0 (DE-588)1077113641  |0 (DE-627)836027280  |0 (DE-576)170866459  |4 aut 
700 1 |a Debus, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1022671421  |0 (DE-627)717025780  |0 (DE-576)365774944  |4 aut 
700 1 |a Klüter, Sebastian  |d 1980-  |e VerfasserIn  |0 (DE-588)1071160796  |0 (DE-627)825622646  |0 (DE-576)311255248  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 69(2024), 18, Artikel-ID 185013, Seite 1-14  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Online MR-guided proton and ion beam radiotherapy investigation of image quality 
773 1 8 |g volume:69  |g year:2024  |g number:18  |g elocationid:185013  |g pages:1-14  |g extent:14  |a Online MR-guided proton and ion beam radiotherapy investigation of image quality 
856 4 0 |u https://doi.org/10.1088/1361-6560/ad7453  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://dx.doi.org/10.1088/1361-6560/ad7453  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20250303 
993 |a Article 
994 |a 2024 
998 |g 1071160796  |a Klüter, Sebastian  |m 1071160796:Klüter, Sebastian  |d 910000  |d 911400  |e 910000PK1071160796  |e 911400PK1071160796  |k 0/910000/  |k 1/910000/911400/  |p 11  |y j 
998 |g 1022671421  |a Debus, Jürgen  |m 1022671421:Debus, Jürgen  |d 910000  |d 911400  |e 910000PD1022671421  |e 911400PD1022671421  |k 0/910000/  |k 1/910000/911400/  |p 10 
998 |g 1077113641  |a Karger, Christian  |m 1077113641:Karger, Christian  |d 50000  |e 50000PK1077113641  |k 0/50000/  |p 9 
998 |g 123579198  |a Haberer, Thomas  |m 123579198:Haberer, Thomas  |d 910000  |d 950000  |d 950400  |e 910000PH123579198  |e 950000PH123579198  |e 950400PH123579198  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 8 
998 |g 135843087X  |a Beyer, Cedric  |m 135843087X:Beyer, Cedric  |d 910000  |d 911400  |e 910000PB135843087X  |e 911400PB135843087X  |k 0/910000/  |k 1/910000/911400/  |p 4 
998 |g 1187162752  |a Dorsch, Stefan  |m 1187162752:Dorsch, Stefan  |d 910000  |d 911400  |e 910000PD1187162752  |e 911400PD1187162752  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 1079849041  |a Paul, Katharina  |m 1079849041:Paul, Katharina  |d 910000  |d 911400  |e 910000PP1079849041  |e 911400PP1079849041  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1918898766  |e 4680569212 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"noteIll":"Illustrationen","extent":"14 S."}],"recId":"1918898766","note":["Gesehen am 03.03.2025"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"title":[{"title_sort":"Online MR-guided proton and ion beam radiotherapy","title":"Online MR-guided proton and ion beam radiotherapy","subtitle":"investigation of image quality"}],"relHost":[{"pubHistory":["1.1956 -"],"origin":[{"dateIssuedDisp":"1956-","dateIssuedKey":"1956","publisherPlace":"Bristol","publisher":"IOP Publ."}],"title":[{"subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title_sort":"Physics in medicine and biology","title":"Physics in medicine and biology"}],"part":{"text":"69(2024), 18, Artikel-ID 185013, Seite 1-14","extent":"14","issue":"18","pages":"1-14","volume":"69","year":"2024"},"id":{"issn":["1361-6560"],"eki":["269016163"],"zdb":["1473501-5"]},"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"269016163","physDesc":[{"extent":"Online-Ressource"}],"disp":"Online MR-guided proton and ion beam radiotherapy investigation of image qualityPhysics in medicine and biology"}],"person":[{"display":"Paul, Katharina","role":"aut","given":"Katharina","family":"Paul"},{"display":"Dorsch, Stefan","family":"Dorsch","role":"aut","given":"Stefan"},{"display":"Elter, Alina","family":"Elter","role":"aut","given":"Alina"},{"family":"Beyer","given":"Cedric","role":"aut","display":"Beyer, Cedric"},{"display":"Naumann, Jakob","role":"aut","given":"Jakob","family":"Naumann"},{"role":"aut","given":"Tim","family":"Hansmann","display":"Hansmann, Tim"},{"display":"Feldmeier, Elisabeth","family":"Feldmeier","given":"Elisabeth","role":"aut"},{"display":"Haberer, Thomas","role":"aut","given":"Thomas","family":"Haberer"},{"display":"Karger, Christian","role":"aut","given":"Christian","family":"Karger"},{"display":"Debus, Jürgen","family":"Debus","given":"Jürgen","role":"aut"},{"display":"Klüter, Sebastian","given":"Sebastian","role":"aut","family":"Klüter"}],"origin":[{"dateIssuedDisp":"13 September 2024","dateIssuedKey":"2024"}],"id":{"doi":["10.1088/1361-6560/ad7453"],"eki":["1918898766"]},"name":{"displayForm":["K Paul, S Dorsch, A Elter, C Beyer, J Naumann, T Hansmann, E Feldmeier, T Haberer, C P Karger, J Debus and S Klüter"]}} 
SRT |a PAULKATHARONLINEMRGU1320