Comparison of surgical times between manual and robot-assisted epiretinal membrane peeling

Epiretinal membranes (ERM) pose a common challenge in vitreoretinal pathology, often causing vision impairment in older adults. The Preceyes Surgical System (PSS) supports the surgical removal of ERM through robot-assisted membrane peeling (RA-MP). This study compares surgical times and iatrogenic h...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Eberle, Alexander (VerfasserIn) , Turgut, Ferhat (VerfasserIn) , Somfai, Gábor Márk (VerfasserIn) , Saad, Amr (VerfasserIn) , de Smet, Marc D. (VerfasserIn) , Hasler, Pascal W. (VerfasserIn) , Heussen, Florian M. (VerfasserIn) , Becker, Matthias D. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: August 14, 2024
In: Translational Vision Science & Technology
Year: 2024, Jahrgang: 13, Heft: 8, Pages: 1-7
ISSN:2164-2591
DOI:10.1167/tvst.13.8.27
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1167/tvst.13.8.27
Volltext
Verfasserangaben:Alexander Eberle, Ferhat Turgut, Gábor Márk Somfai, Amr Saad, Marc D. de Smet, Pascal W. Hasler, Florian M. Heussen, and Matthias D. Becker

MARC

LEADER 00000caa a2200000 c 4500
001 1919306137
003 DE-627
005 20250716235656.0
007 cr uuu---uuuuu
008 250307s2024 xx |||||o 00| ||eng c
024 7 |a 10.1167/tvst.13.8.27  |2 doi 
035 |a (DE-627)1919306137 
035 |a (DE-599)KXP1919306137 
035 |a (OCoLC)1528020220 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Eberle, Alexander  |e VerfasserIn  |0 (DE-588)1358972109  |0 (DE-627)1919306862  |4 aut 
245 1 0 |a Comparison of surgical times between manual and robot-assisted epiretinal membrane peeling  |c Alexander Eberle, Ferhat Turgut, Gábor Márk Somfai, Amr Saad, Marc D. de Smet, Pascal W. Hasler, Florian M. Heussen, and Matthias D. Becker 
264 1 |c August 14, 2024 
300 |b Illustrationen 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 07.03.2025 
520 |a Epiretinal membranes (ERM) pose a common challenge in vitreoretinal pathology, often causing vision impairment in older adults. The Preceyes Surgical System (PSS) supports the surgical removal of ERM through robot-assisted membrane peeling (RA-MP). This study compares surgical times and iatrogenic hemorrhages between manual membrane peeling (MMP) and RA-MP using PSS. Nine patients underwent RA-MP with PSS, whereas 16 patients (18 eyes) underwent MMP for comparative analysis. Surgical durations were categorized into RA-MP, manual forceps utilization in PSS surgeries (mRA-MP), and traditional MMP. Cumulative manual manipulation duration (cMMP), instrument grasps, and intraoperative hemorrhages were statistically analyzed using the Mann-Whitney U test. RA-MP showed significantly longer peeling times compared to MMP (P < 0.001). Flap initiation grasps were similar between methods (P = 0.86), RA-MP demonstrated a significant reduction in peeling grasps (P = 0.01) and mean grasps per minute (P < 0.001). Although RA-MP resulted in fewer hemorrhages, the difference did not reach statistical significance relative to MMP (P = 0.08). Although RA-MP tended to extend surgical time, it offered advantages in reducing tissue trauma and intraoperative hemorrhages. Further research is needed to explore the learning curve for novice surgeons and evaluate the safety profile of RA-MP. RA-MP may offer potential advantages over manual surgery, particularly in terms of reduced tissue trauma and intraoperative hemorrhages. Despite its longer duration compared with manual techniques, RA-MP may lead to fewer grasping maneuvers and lower rates of hemorrhages, thereby enhancing the safety and precision of vitreoretinal surgeries. 
700 1 |a Turgut, Ferhat  |e VerfasserIn  |4 aut 
700 1 |a Somfai, Gábor Márk  |e VerfasserIn  |4 aut 
700 1 |a Saad, Amr  |e VerfasserIn  |4 aut 
700 1 |a de Smet, Marc D.  |e VerfasserIn  |4 aut 
700 1 |a Hasler, Pascal W.  |e VerfasserIn  |4 aut 
700 1 |a Heussen, Florian M.  |e VerfasserIn  |4 aut 
700 1 |a Becker, Matthias D.  |e VerfasserIn  |0 (DE-588)135571855  |0 (DE-627)56707255X  |0 (DE-576)300521871  |4 aut 
773 0 8 |i Enthalten in  |t Translational Vision Science & Technology  |d Rockville, Md. : ARVO, 2012  |g 13(2024), 8, Artikel-ID 27, Seite 1-7  |h Online-Ressource  |w (DE-627)721581072  |w (DE-600)2674602-5  |w (DE-576)369466659  |x 2164-2591  |7 nnas  |a Comparison of surgical times between manual and robot-assisted epiretinal membrane peeling 
773 1 8 |g volume:13  |g year:2024  |g number:8  |g elocationid:27  |g pages:1-7  |g extent:7  |a Comparison of surgical times between manual and robot-assisted epiretinal membrane peeling 
856 4 0 |u https://doi.org/10.1167/tvst.13.8.27  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20250307 
993 |a Article 
994 |a 2024 
998 |g 135571855  |a Becker, Matthias D.  |m 135571855:Becker, Matthias D.  |d 50000  |e 50000PB135571855  |k 0/50000/  |p 8  |y j 
999 |a KXP-PPN1919306137  |e 4683826100 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"part":{"year":"2024","issue":"8","text":"13(2024), 8, Artikel-ID 27, Seite 1-7","extent":"7","pages":"1-7","volume":"13"},"id":{"eki":["721581072"],"zdb":["2674602-5"],"issn":["2164-2591"]},"origin":[{"dateIssuedKey":"2012","publisher":"ARVO","dateIssuedDisp":"2012-","publisherPlace":"Rockville, Md."}],"disp":"Comparison of surgical times between manual and robot-assisted epiretinal membrane peelingTranslational Vision Science & Technology","name":{"displayForm":["Association for Research in Vision and Opthalmology"]},"recId":"721581072","title":[{"title":"Translational Vision Science & Technology","subtitle":"TVST","title_sort":"Translational Vision Science & Technology"}],"pubHistory":["1.2012 -"],"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"TVST"}],"note":["Gesehen am 23.04.2015"]}],"note":["Gesehen am 07.03.2025"],"name":{"displayForm":["Alexander Eberle, Ferhat Turgut, Gábor Márk Somfai, Amr Saad, Marc D. de Smet, Pascal W. Hasler, Florian M. Heussen, and Matthias D. Becker"]},"recId":"1919306137","id":{"eki":["1919306137"],"doi":["10.1167/tvst.13.8.27"]},"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"August 14, 2024"}],"language":["eng"],"physDesc":[{"extent":"7 S.","noteIll":"Illustrationen"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"person":[{"family":"Eberle","given":"Alexander","role":"aut","display":"Eberle, Alexander"},{"display":"Turgut, Ferhat","family":"Turgut","given":"Ferhat","role":"aut"},{"given":"Gábor Márk","role":"aut","family":"Somfai","display":"Somfai, Gábor Márk"},{"display":"Saad, Amr","role":"aut","given":"Amr","family":"Saad"},{"display":"de Smet, Marc D.","role":"aut","given":"Marc D.","family":"de Smet"},{"display":"Hasler, Pascal W.","family":"Hasler","role":"aut","given":"Pascal W."},{"display":"Heussen, Florian M.","role":"aut","given":"Florian M.","family":"Heussen"},{"display":"Becker, Matthias D.","given":"Matthias D.","role":"aut","family":"Becker"}],"title":[{"title":"Comparison of surgical times between manual and robot-assisted epiretinal membrane peeling","title_sort":"Comparison of surgical times between manual and robot-assisted epiretinal membrane peeling"}]} 
SRT |a EBERLEALEXCOMPARISON1420