Neuromagnetic responses reflect the temporal pitch change of regular interval sounds

The pitch onset response (POR) evoked by the transition between two regular interval sounds (RIS) with different pitch was studied by recording the neuromagnetic responses with a 122-channel whole head magnetoencephalograph (MEG). The parameters of RIS were varied giving rise to characteristic chang...

Full description

Saved in:
Bibliographic Details
Main Authors: Ritter, Steffen (Author) , Dosch, Hans Günter (Author) , Specht, Hans Joachim (Author) , Rupp, André (Author)
Format: Article (Journal)
Language:English
Published: September 2005
In: NeuroImage
Year: 2005, Volume: 27, Issue: 3, Pages: 533-543
ISSN:1095-9572
DOI:10.1016/j.neuroimage.2005.05.003
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.neuroimage.2005.05.003
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1053811905003137
Get full text
Author Notes:Steffen Ritter, Hans Günter Dosch, Hans-Joachim Specht, and André Rupp

MARC

LEADER 00000caa a2200000 c 4500
001 1919427198
003 DE-627
005 20250717000111.0
007 cr uuu---uuuuu
008 250310s2005 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.neuroimage.2005.05.003  |2 doi 
035 |a (DE-627)1919427198 
035 |a (DE-599)KXP1919427198 
035 |a (OCoLC)1528025864 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Ritter, Steffen  |e VerfasserIn  |0 (DE-588)1298514878  |0 (DE-627)1854491199  |4 aut 
245 1 0 |a Neuromagnetic responses reflect the temporal pitch change of regular interval sounds  |c Steffen Ritter, Hans Günter Dosch, Hans-Joachim Specht, and André Rupp 
264 1 |c September 2005 
300 |b Diagramme 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online veröffentlicht: 17. Juni 2005 
500 |a Gesehen am 10.03.2025 
520 |a The pitch onset response (POR) evoked by the transition between two regular interval sounds (RIS) with different pitch was studied by recording the neuromagnetic responses with a 122-channel whole head magnetoencephalograph (MEG). The parameters of RIS were varied giving rise to characteristic changes in the latency of the first prominent deflection occurring about 100 to 140 ms after the transition. These latency differences of the neurophysiological signal correlated strongly with the psychoacoustic findings obtained from the same individuals. Some of the observed changes cannot be explained by obvious physical differences as changes in the spectrum, but only by temporal processing mechanisms as the auditory image model (Patterson, R.D., Allerhand, M., Giguere, C., 1995. Time-domain modelling of peripheral auditory processing: a modular architecture and a software platform. J. Acoust. Soc. Am. 98, 1890-1894). The location of the POR evoked by the transition was found to be in lateral Heschl's Gyrus, which gives further evidence that this is the center of processing pitch changes in the auditory cortex. 
650 4 |a Auditory cortex 
650 4 |a Magnetoencephalography 
650 4 |a Pitch onset response 
650 4 |a Pitch perception 
650 4 |a Temporal pitch 
700 1 |a Dosch, Hans Günter  |d 1936-  |e VerfasserIn  |0 (DE-588)106206745  |0 (DE-627)500674655  |0 (DE-576)160772710  |4 aut 
700 1 |a Specht, Hans Joachim  |d 1936-2024  |e VerfasserIn  |0 (DE-588)106505769  |0 (DE-627)690934386  |0 (DE-576)301257353  |4 aut 
700 1 |a Rupp, André  |d 1962-  |e VerfasserIn  |0 (DE-588)121268527  |0 (DE-627)705347079  |0 (DE-576)181320827  |4 aut 
773 0 8 |i Enthalten in  |t NeuroImage  |d Orlando, Fla. : Academic Press, 1992  |g 27(2005), 3 vom: Sept., Seite 533-543  |h Online-Ressource  |w (DE-627)268125503  |w (DE-600)1471418-8  |w (DE-576)106869507  |x 1095-9572  |7 nnas  |a Neuromagnetic responses reflect the temporal pitch change of regular interval sounds 
773 1 8 |g volume:27  |g year:2005  |g number:3  |g month:09  |g pages:533-543  |g extent:11  |a Neuromagnetic responses reflect the temporal pitch change of regular interval sounds 
856 4 0 |u https://doi.org/10.1016/j.neuroimage.2005.05.003  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1053811905003137  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20250310 
993 |a Article 
994 |a 2005 
998 |g 121268527  |a Rupp, André  |m 121268527:Rupp, André  |d 910000  |d 911100  |e 910000PR121268527  |e 911100PR121268527  |k 0/910000/  |k 1/910000/911100/  |p 4  |y j 
998 |g 106505769  |a Specht, Hans Joachim  |m 106505769:Specht, Hans Joachim  |d 130000  |e 130000PS106505769  |k 0/130000/  |p 3 
998 |g 106206745  |a Dosch, Hans Günter  |m 106206745:Dosch, Hans Günter  |d 130000  |e 130000PD106206745  |k 0/130000/  |p 2 
998 |g 1298514878  |a Ritter, Steffen  |m 1298514878:Ritter, Steffen  |d 130000  |e 130000PR1298514878  |k 0/130000/  |p 1  |x j 
999 |a KXP-PPN1919427198  |e 4685716752 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedDisp":"September 2005","dateIssuedKey":"2005"}],"note":["Online veröffentlicht: 17. Juni 2005","Gesehen am 10.03.2025"],"relHost":[{"disp":"Neuromagnetic responses reflect the temporal pitch change of regular interval soundsNeuroImage","physDesc":[{"extent":"Online-Ressource"}],"title":[{"subtitle":"a journal of brain function","title_sort":"NeuroImage","title":"NeuroImage"}],"part":{"pages":"533-543","year":"2005","text":"27(2005), 3 vom: Sept., Seite 533-543","extent":"11","volume":"27","issue":"3"},"type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"268125503","pubHistory":["Volume 1, issue 1 (august 1992)-"],"note":["Fortsetzung der Druck-Ausgabe","Gesehen am 29.06.20"],"origin":[{"publisherPlace":"Orlando, Fla.","publisher":"Academic Press","dateIssuedDisp":"[1992]-"}],"id":{"issn":["1095-9572"],"eki":["268125503"],"zdb":["1471418-8"]},"language":["eng"]}],"recId":"1919427198","type":{"bibl":"article-journal","media":"Online-Ressource"},"name":{"displayForm":["Steffen Ritter, Hans Günter Dosch, Hans-Joachim Specht, and André Rupp"]},"language":["eng"],"id":{"eki":["1919427198"],"doi":["10.1016/j.neuroimage.2005.05.003"]},"physDesc":[{"noteIll":"Diagramme","extent":"11 S."}],"title":[{"title":"Neuromagnetic responses reflect the temporal pitch change of regular interval sounds","title_sort":"Neuromagnetic responses reflect the temporal pitch change of regular interval sounds"}],"person":[{"role":"aut","display":"Ritter, Steffen","given":"Steffen","family":"Ritter"},{"family":"Dosch","given":"Hans Günter","display":"Dosch, Hans Günter","role":"aut"},{"family":"Specht","role":"aut","given":"Hans Joachim","display":"Specht, Hans Joachim"},{"family":"Rupp","given":"André","display":"Rupp, André","role":"aut"}]} 
SRT |a RITTERSTEFNEUROMAGNE2005