Influence of artificial landmarks on the accuracy of complete arch scans in the partially edentulous maxilla: an in vitro study

Statement of problem - Scan path length and the presence of edentulous alveolar ridge sections have a negative influence on scanning accuracy. How different artificial landmarks combined with an adapted scanning method affect accuracy is unclear. - Purpose - The purpose of this in vitro study was to...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Waldecker, Moritz (VerfasserIn) , Bömicke, Wolfgang (VerfasserIn) , Awounvo Awounvo, Junior Sinclair (VerfasserIn) , Rammelsberg, Peter (VerfasserIn) , Rues, Stefan (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: October 2024
In: The journal of prosthetic dentistry
Year: 2024, Jahrgang: 132, Heft: 4, Pages: 829-837
ISSN:1097-6841
DOI:10.1016/j.prosdent.2022.08.011
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.prosdent.2022.08.011
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0022391322005078
Volltext
Verfasserangaben:Moritz Waldecker, Dr med dent, Wolfgang Bömicke, Prof Dr med dent, MSc, Sinclair Awounvo Awounvo, MSc, Peter Rammelsberg, Prof Dr med dent, and Stefan Rues, Dipl-Ing

MARC

LEADER 00000caa a2200000 c 4500
001 1920544747
003 DE-627
005 20260204170945.0
007 cr uuu---uuuuu
008 250325s2024 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.prosdent.2022.08.011  |2 doi 
035 |a (DE-627)1920544747 
035 |a (DE-599)KXP1920544747 
035 |a (OCoLC)1528043632 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Waldecker, Moritz  |d 1986-  |e VerfasserIn  |0 (DE-588)114780172X  |0 (DE-627)1007199024  |0 (DE-576)496051652  |4 aut 
245 1 0 |a Influence of artificial landmarks on the accuracy of complete arch scans in the partially edentulous maxilla  |b an in vitro study  |c Moritz Waldecker, Dr med dent, Wolfgang Bömicke, Prof Dr med dent, MSc, Sinclair Awounvo Awounvo, MSc, Peter Rammelsberg, Prof Dr med dent, and Stefan Rues, Dipl-Ing 
264 1 |c October 2024 
300 |b Illustrationen 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 25.03.2025 
520 |a Statement of problem - Scan path length and the presence of edentulous alveolar ridge sections have a negative influence on scanning accuracy. How different artificial landmarks combined with an adapted scanning method affect accuracy is unclear. - Purpose - The purpose of this in vitro study was to determine the influence of 2 different artificial landmarks combined with an adapted scanning method on the scanning accuracy of a partially edentulous maxillary model. - Material and methods - The model simulated a maxilla with 6 prepared teeth to accommodate a complete arch fixed partial denture. Five ceramic precision balls (ball center P1-P5), distributed buccally to the dental arch, were used to detect the dimensional and angular changes between the reference model and the intraoral scans. One intraoral scanner (Primescan) was used to make 30 scans each with either the scanning strategy recommended by the manufacturer (M) or with an adapted scanning strategy and the use of a bar (B) or 4 plates (P) as artificial landmarks in the dorsal palate. Data were statistically analyzed using a generalized least squares regression model (α=.05). - Results - Scanning with artificial landmarks reduced the maximum absolute distance deviations (M: 249 μm, B: 190 μm, P: 238 μm) and the maximum angle deviations (M: 0.31 degrees, B: 0.28 degrees, P: 0.26 degrees). Vertical distance deviations were improved by 10 to 50% with the use of artificial landmarks. Absolute mean distance deviations were significantly lower for group M (P<.001). In contrast, with artificial landmarks, mean angle (P<.001) and mean vertical distance deviations (P<.014) improved significantly. - Conclusions - Scanning with artificial landmarks in the dorsal palate combined with an adapted scanning method improved the scanning accuracy and reliability of vertical distance deviations. 
700 1 |a Bömicke, Wolfgang  |d 1981-  |e VerfasserIn  |0 (DE-588)1015022146  |0 (DE-627)668338792  |0 (DE-576)349947651  |4 aut 
700 1 |a Awounvo Awounvo, Junior Sinclair  |e VerfasserIn  |0 (DE-588)1306960894  |0 (DE-627)1867294869  |4 aut 
700 1 |a Rammelsberg, Peter  |d 1959-  |e VerfasserIn  |0 (DE-588)122469836  |0 (DE-627)705920836  |0 (DE-576)293285640  |4 aut 
700 1 |a Rues, Stefan  |e VerfasserIn  |0 (DE-588)1054444927  |0 (DE-627)792098331  |0 (DE-576)410292168  |4 aut 
773 0 8 |i Enthalten in  |t The journal of prosthetic dentistry  |d London [u.a.] : Elsevier, 1951  |g 132(2024), 4 vom: Okt., Seite 829-837  |h Online-Ressource  |w (DE-627)320495787  |w (DE-600)2011581-7  |w (DE-576)09101509X  |x 1097-6841  |7 nnas  |a Influence of artificial landmarks on the accuracy of complete arch scans in the partially edentulous maxilla an in vitro study 
773 1 8 |g volume:132  |g year:2024  |g number:4  |g month:10  |g pages:829-837  |g extent:9  |a Influence of artificial landmarks on the accuracy of complete arch scans in the partially edentulous maxilla an in vitro study 
856 4 0 |u https://doi.org/10.1016/j.prosdent.2022.08.011  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext  |7 1 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0022391322005078  |x Verlag  |z lizenzpflichtig  |3 Volltext  |7 1 
951 |a AR 
992 |a 20250325 
993 |a Article 
994 |a 2024 
998 |g 1054444927  |a Rues, Stefan  |m 1054444927:Rues, Stefan  |d 910000  |d 910800  |e 910000PR1054444927  |e 910800PR1054444927  |k 0/910000/  |k 1/910000/910800/  |p 5  |y j 
998 |g 122469836  |a Rammelsberg, Peter  |m 122469836:Rammelsberg, Peter  |d 910000  |d 910800  |e 910000PR122469836  |e 910800PR122469836  |k 0/910000/  |k 1/910000/910800/  |p 4 
998 |g 1306960894  |a Awounvo Awounvo, Junior Sinclair  |m 1306960894:Awounvo Awounvo, Junior Sinclair  |d 910000  |d 911800  |e 910000PA1306960894  |e 911800PA1306960894  |k 0/910000/  |k 1/910000/911800/  |p 3 
998 |g 1015022146  |a Bömicke, Wolfgang  |m 1015022146:Bömicke, Wolfgang  |d 910000  |d 910800  |d 50000  |e 910000PB1015022146  |e 910800PB1015022146  |e 50000PB1015022146  |k 0/910000/  |k 1/910000/910800/  |k 0/50000/  |p 2 
998 |g 114780172X  |a Waldecker, Moritz  |m 114780172X:Waldecker, Moritz  |d 910000  |d 910800  |e 910000PW114780172X  |e 910800PW114780172X  |k 0/910000/  |k 1/910000/910800/  |p 1  |x j 
999 |a KXP-PPN1920544747  |e 4692636009 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["1920544747"],"doi":["10.1016/j.prosdent.2022.08.011"]},"language":["eng"],"origin":[{"dateIssuedDisp":"October 2024","dateIssuedKey":"2024"}],"relHost":[{"disp":"Influence of artificial landmarks on the accuracy of complete arch scans in the partially edentulous maxilla an in vitro studyThe journal of prosthetic dentistry","note":["Gesehen am 07.08.25"],"pubHistory":["1.1951 -"],"recId":"320495787","origin":[{"dateIssuedDisp":"1951-","publisherPlace":"London [u.a.] ; St. Louis, Mo.","publisher":"Elsevier ; Mosby","dateIssuedKey":"1951"}],"id":{"eki":["320495787"],"zdb":["2011581-7"],"issn":["1097-6841"]},"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"part":{"issue":"4","year":"2024","extent":"9","pages":"829-837","text":"132(2024), 4 vom: Okt., Seite 829-837","volume":"132"},"titleAlt":[{"title":"JPD"}],"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"The journal of prosthetic dentistry","title_sort":"journal of prosthetic dentistry"}]}],"physDesc":[{"noteIll":"Illustrationen","extent":"9 S."}],"person":[{"role":"aut","display":"Waldecker, Moritz","family":"Waldecker","given":"Moritz"},{"display":"Bömicke, Wolfgang","family":"Bömicke","given":"Wolfgang","role":"aut"},{"given":"Junior Sinclair","family":"Awounvo Awounvo","display":"Awounvo Awounvo, Junior Sinclair","role":"aut"},{"given":"Peter","display":"Rammelsberg, Peter","family":"Rammelsberg","role":"aut"},{"given":"Stefan","family":"Rues","display":"Rues, Stefan","role":"aut"}],"title":[{"subtitle":"an in vitro study","title":"Influence of artificial landmarks on the accuracy of complete arch scans in the partially edentulous maxilla","title_sort":"Influence of artificial landmarks on the accuracy of complete arch scans in the partially edentulous maxilla"}],"recId":"1920544747","note":["Gesehen am 25.03.2025"],"name":{"displayForm":["Moritz Waldecker, Dr med dent, Wolfgang Bömicke, Prof Dr med dent, MSc, Sinclair Awounvo Awounvo, MSc, Peter Rammelsberg, Prof Dr med dent, and Stefan Rues, Dipl-Ing"]}} 
SRT |a WALDECKERMINFLUENCEO2024