Artificial Intelligence to derive aligned strain in cine CMR to detect patients with myocardial fibrosis: an open and scrutinizable approach

Cine Cardiac Magnetic Resonance (CMR) is the gold standard for cardiac function evaluation, incorporating ejection fraction (EF) and strain as vital indicators of abnormal deformation. Rare pathologies like Duchenne muscular dystrophies (DMD) are monitored with repeated late gadolinium-enhanced (LGE...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Köhler, Sven (VerfasserIn) , Kuhm, Julian (VerfasserIn) , Huffaker, Tyler (VerfasserIn) , Young, Daniel (VerfasserIn) , Tandon, Animesh (VerfasserIn) , André, Florian (VerfasserIn) , Frey, Norbert (VerfasserIn) , Greil, Gerald (VerfasserIn) , Hussain, Tarique (VerfasserIn) , Engelhardt, Sandy (VerfasserIn)
Dokumenttyp: Article (Journal) Kapitel/Artikel
Sprache:Englisch
Veröffentlicht: 04 Jan, 2024
In: Research Square
Year: 2024, Pages: 1-21
ISSN:2693-5015
DOI:10.21203/rs.3.rs-3785677/v1
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.21203/rs.3.rs-3785677/v1
Verlag, kostenfrei, Volltext: https://www.researchsquare.com/article/rs-3785677/v1
Volltext
Verfasserangaben:Sven Koehler, Julian Kuhm, Tyler Huffaker, Daniel Young, Animesh Tandon, Florian Andre, Norbert Frey, Gerald Greil, Tarique Hussain, Sandy Engelhardt

MARC

LEADER 00000caa a2200000 c 4500
001 1920908366
003 DE-627
005 20250717004043.0
007 cr uuu---uuuuu
008 250401s2024 xx |||||o 00| ||eng c
024 7 |a 10.21203/rs.3.rs-3785677/v1  |2 doi 
035 |a (DE-627)1920908366 
035 |a (DE-599)KXP1920908366 
035 |a (OCoLC)1528043950 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Köhler, Sven  |e VerfasserIn  |0 (DE-588)124712830X  |0 (DE-627)1780697864  |4 aut 
245 1 0 |a Artificial Intelligence to derive aligned strain in cine CMR to detect patients with myocardial fibrosis  |b an open and scrutinizable approach  |c Sven Koehler, Julian Kuhm, Tyler Huffaker, Daniel Young, Animesh Tandon, Florian Andre, Norbert Frey, Gerald Greil, Tarique Hussain, Sandy Engelhardt 
264 1 |c 04 Jan, 2024 
300 |a 21 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 01.04.2025 
520 |a Cine Cardiac Magnetic Resonance (CMR) is the gold standard for cardiac function evaluation, incorporating ejection fraction (EF) and strain as vital indicators of abnormal deformation. Rare pathologies like Duchenne muscular dystrophies (DMD) are monitored with repeated late gadolinium-enhanced (LGE) CMR for identification of myocardial fibrosis. However, it is judicious to reduce repeated gadolinium exposure and rather employ strain analysis from cine CMR. This solution is limited so far since full strain curves are not comparable between individual cardiac cycles and current practice mainly neglects diastolic deformation patterns. Our novel Deep Learning-based approach derives strain values aligned by key frames throughout the cardiac cycle. In a reproducibility scenario (57+82 patients), our results reveal five times more significant differences (22 vs. 4) between patients with scar and without, enhancing scar detection by +30%, improving detection of patients with preserved EF by +61%, with an overall sensitivity/specificity of 82/81%. 
700 1 |a Kuhm, Julian  |e VerfasserIn  |0 (DE-588)1186911824  |0 (DE-627)1666191507  |4 aut 
700 1 |a Huffaker, Tyler  |e VerfasserIn  |4 aut 
700 1 |a Young, Daniel  |e VerfasserIn  |4 aut 
700 1 |a Tandon, Animesh  |e VerfasserIn  |4 aut 
700 1 |a André, Florian  |d 1983-  |e VerfasserIn  |0 (DE-588)1051060230  |0 (DE-627)785671714  |0 (DE-576)405733267  |4 aut 
700 1 |a Frey, Norbert  |e VerfasserIn  |0 (DE-588)141244976  |0 (DE-627)625824075  |0 (DE-576)322969514  |4 aut 
700 1 |a Greil, Gerald  |e VerfasserIn  |4 aut 
700 1 |a Hussain, Tarique  |e VerfasserIn  |4 aut 
700 1 |a Engelhardt, Sandy  |d 1987-  |e VerfasserIn  |0 (DE-588)1122674465  |0 (DE-627)876003080  |0 (DE-576)481436049  |4 aut 
773 0 8 |i Enthalten in  |t Research Square  |d Durham, NC : Research Square, 2020  |g (2024) vom: Jan., Seite 1-21  |h Online-Ressource  |w (DE-627)1736564625  |w (DE-600)3042859-2  |x 2693-5015  |7 nnas  |a Artificial Intelligence to derive aligned strain in cine CMR to detect patients with myocardial fibrosis an open and scrutinizable approach 
773 1 8 |g year:2024  |g month:01  |g pages:1-21  |g extent:21  |a Artificial Intelligence to derive aligned strain in cine CMR to detect patients with myocardial fibrosis an open and scrutinizable approach 
856 4 0 |u https://doi.org/10.21203/rs.3.rs-3785677/v1  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.researchsquare.com/article/rs-3785677/v1  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20250401 
993 |a Article 
994 |a 2024 
998 |g 1122674465  |a Engelhardt, Sandy  |m 1122674465:Engelhardt, Sandy  |d 910000  |d 910100  |e 910000PE1122674465  |e 910100PE1122674465  |k 0/910000/  |k 1/910000/910100/  |p 10  |y j 
998 |g 141244976  |a Frey, Norbert  |m 141244976:Frey, Norbert  |d 910000  |d 910100  |e 910000PF141244976  |e 910100PF141244976  |k 0/910000/  |k 1/910000/910100/  |p 7 
998 |g 1051060230  |a André, Florian  |m 1051060230:André, Florian  |d 910000  |d 910100  |d 50000  |e 910000PA1051060230  |e 910100PA1051060230  |e 50000PA1051060230  |k 0/910000/  |k 1/910000/910100/  |k 0/50000/  |p 6 
998 |g 1186911824  |a Kuhm, Julian  |m 1186911824:Kuhm, Julian  |d 50000  |e 50000PK1186911824  |k 0/50000/  |p 2 
998 |g 124712830X  |a Köhler, Sven  |m 124712830X:Köhler, Sven  |d 910000  |d 910100  |e 910000PK124712830X  |e 910100PK124712830X  |k 0/910000/  |k 1/910000/910100/  |p 1  |x j 
999 |a KXP-PPN1920908366  |e 4695815834 
BIB |a Y 
JSO |a {"type":{"bibl":"chapter","media":"Online-Ressource"},"origin":[{"dateIssuedDisp":"04 Jan, 2024","dateIssuedKey":"2024"}],"name":{"displayForm":["Sven Koehler, Julian Kuhm, Tyler Huffaker, Daniel Young, Animesh Tandon, Florian Andre, Norbert Frey, Gerald Greil, Tarique Hussain, Sandy Engelhardt"]},"title":[{"subtitle":"an open and scrutinizable approach","title_sort":"Artificial Intelligence to derive aligned strain in cine CMR to detect patients with myocardial fibrosis","title":"Artificial Intelligence to derive aligned strain in cine CMR to detect patients with myocardial fibrosis"}],"person":[{"display":"Köhler, Sven","role":"aut","given":"Sven","family":"Köhler"},{"family":"Kuhm","role":"aut","given":"Julian","display":"Kuhm, Julian"},{"display":"Huffaker, Tyler","given":"Tyler","role":"aut","family":"Huffaker"},{"display":"Young, Daniel","role":"aut","given":"Daniel","family":"Young"},{"display":"Tandon, Animesh","family":"Tandon","role":"aut","given":"Animesh"},{"family":"André","given":"Florian","role":"aut","display":"André, Florian"},{"display":"Frey, Norbert","role":"aut","given":"Norbert","family":"Frey"},{"family":"Greil","role":"aut","given":"Gerald","display":"Greil, Gerald"},{"family":"Hussain","role":"aut","given":"Tarique","display":"Hussain, Tarique"},{"display":"Engelhardt, Sandy","family":"Engelhardt","role":"aut","given":"Sandy"}],"physDesc":[{"extent":"21 S."}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"note":["Research Square is a leading author, editorial, and video services provider. We are a trusted partner to many of the leading academic publishers, institutions, and societies worldwide. Research Square is a mission-driven business focused on developing innovative software and services for the global research community. We run the largest author services company, American Journal Experts (AJE), and have supported over 775,000 manuscripts from researchers in 192 countries","Gesehen am 26.10.2020"],"type":{"media":"Online-Ressource","bibl":"edited-book"},"part":{"pages":"1-21","text":"(2024) vom: Jan., Seite 1-21","year":"2024","extent":"21"},"origin":[{"dateIssuedDisp":"[2020?]-","dateIssuedKey":"2020","publisherPlace":"Durham, NC","publisher":"Research Square"}],"title":[{"title":"Research Square","title_sort":"Research Square"}],"recId":"1736564625","id":{"issn":["2693-5015"],"eki":["1736564625"],"zdb":["3042859-2"]},"titleAlt":[{"title":"Research square preprint platform - share and discover new research"}],"disp":"Artificial Intelligence to derive aligned strain in cine CMR to detect patients with myocardial fibrosis an open and scrutinizable approachResearch Square","language":["eng"]}],"note":["Gesehen am 01.04.2025"],"language":["eng"],"id":{"eki":["1920908366"],"doi":["10.21203/rs.3.rs-3785677/v1"]},"recId":"1920908366"} 
SRT |a KOEHLERSVEARTIFICIAL0420