Optimization of anastomotic technique and gastric conduit perfusion with hyperspectral imaging and machine learning in an experimental model for minimally invasive esophagectomy

Introduction - Esophagectomy is the mainstay of esophageal cancer treatment, but anastomotic insufficiency related morbidity and mortality remain challenging for patient outcome. Therefore, the objective of this work was to optimize anastomotic technique and gastric conduit perfusion with hyperspect...

Full description

Saved in:
Bibliographic Details
Main Authors: Nickel, Felix (Author) , Studier-Fischer, Alexander (Author) , Özdemir, Berkin (Author) , Odenthal, Jan (Author) , Müller, Lucas-Raphael (Author) , Knoedler, Samuel (Author) , Kowalewski, Karl-Friedrich (Author) , Camplisson, I. (Author) , Allers, Michael Martin (Author) , Dietrich, Maximilian (Author) , Schmidt, Karsten (Author) , Salg, Gabriel Alexander (Author) , Kenngott, Hannes Götz (Author) , Billeter, Adrian (Author) , Gockel, I. (Author) , Sagiv, C. (Author) , Hadar, O. E. (Author) , Gildenblat, J. (Author) , Ayala, Leonardo (Author) , Seidlitz, Silvia (Author) , Maier-Hein, Lena (Author) , Müller, Beat P. (Author)
Format: Article (Journal)
Language:English
Published: January 2025
In: European journal of surgical oncology
Year: 2025, Volume: 51, Issue: 1, Pages: 1-13
ISSN:1532-2157
DOI:10.1016/j.ejso.2023.04.007
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.ejso.2023.04.007
Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S0748798323004444
Get full text
Author Notes:F. Nickel, A. Studier-Fischer, B. Özdemir, J. Odenthal, L.R. Müller, S. Knoedler, K.F. Kowalewski, I. Camplisson, M.M. Allers, M. Dietrich, K. Schmidt, G.A. Salg, H.G. Kenngott, A.T. Billeter, I. Gockel, C. Sagiv, O.E. Hadar, J. Gildenblat, L. Ayala, S. Seidlitz, L. Maier-Hein, B.P. Müller-Stich

MARC

LEADER 00000caa a2200000 c 4500
001 192544970X
003 DE-627
005 20250913141520.0
007 cr uuu---uuuuu
008 250513s2025 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejso.2023.04.007  |2 doi 
035 |a (DE-627)192544970X 
035 |a (DE-599)KXP192544970X 
035 |a (OCoLC)1528045249 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Nickel, Felix  |d 1982-  |e VerfasserIn  |0 (DE-588)1067980059  |0 (DE-627)819414875  |0 (DE-576)427122619  |4 aut 
245 1 0 |a Optimization of anastomotic technique and gastric conduit perfusion with hyperspectral imaging and machine learning in an experimental model for minimally invasive esophagectomy  |c F. Nickel, A. Studier-Fischer, B. Özdemir, J. Odenthal, L.R. Müller, S. Knoedler, K.F. Kowalewski, I. Camplisson, M.M. Allers, M. Dietrich, K. Schmidt, G.A. Salg, H.G. Kenngott, A.T. Billeter, I. Gockel, C. Sagiv, O.E. Hadar, J. Gildenblat, L. Ayala, S. Seidlitz, L. Maier-Hein, B.P. Müller-Stich 
264 1 |c January 2025 
300 |b Illustrationen, Diagramme 
300 |a 13 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online verfügbar: 18. April 2023, Artikelversion: 14. Dezember 2024 
500 |a Gesehen am 13.05.2025 
520 |a Introduction - Esophagectomy is the mainstay of esophageal cancer treatment, but anastomotic insufficiency related morbidity and mortality remain challenging for patient outcome. Therefore, the objective of this work was to optimize anastomotic technique and gastric conduit perfusion with hyperspectral imaging (HSI) for total minimally invasive esophagectomy (MIE) with linear stapled anastomosis. - Material and methods - A live porcine model (n = 58) for MIE was used with gastric conduit formation and simulation of linear stapled side-to-side esophagogastrostomy. Four main experimental groups differed in stapling length (3 vs. 6 cm) and simulation of anastomotic position on the conduit (cranial vs. caudal). Tissue oxygenation around the anastomotic simulation site was evaluated using HSI and was validated with histopathology. - Results - The tissue oxygenation (ΔStO2) after the anastomotic simulation remained constant only for the short stapler in caudal position (−0.4 ± 4.4%, n.s.) while it was impaired markedly in the other groups (short-cranial: −15.6 ± 11.5%, p = 0.0002; long-cranial: −20.4 ± 7.6%, p = 0.0126; long-caudal: −16.1 ± 9.4%, p < 0.0001). Tissue samples from avascular stomach as measured by HSI showed correspondent eosinophilic pre-necrotic changes in 35.7 ± 9.7% of the surface area. - Conclusion - Tissue oxygenation at the site of anastomotic simulation of the gastric conduit during MIE is influenced by stapling technique. Optimal oxygenation was achieved with a short stapler (3 cm) and sufficient distance of the simulated anastomosis to the cranial end of the gastric conduit. HSI tissue deoxygenation corresponded to histopathologic necrotic tissue changes. The experimental model with HSI and ML allow for systematic optimization of gastric conduit perfusion and anastomotic technique while clinical translation will have to be proven. 
650 4 |a Gastric conduit 
650 4 |a Hyperspectral imaging 
650 4 |a Linear stapled anastomosis 
650 4 |a Minimally invasive esophagectomy 
650 4 |a Porcine model 
650 4 |a Simulation 
650 4 |a Tissue perfusion 
700 1 |a Studier-Fischer, Alexander  |d 1995-  |e VerfasserIn  |0 (DE-588)1196041105  |0 (DE-627)1677916958  |4 aut 
700 1 |a Özdemir, Berkin  |d 1997-  |e VerfasserIn  |0 (DE-588)1252285809  |0 (DE-627)1793432740  |4 aut 
700 1 |a Odenthal, Jan  |e VerfasserIn  |0 (DE-588)1298275202  |0 (DE-627)1854324136  |4 aut 
700 1 |a Müller, Lucas-Raphael  |d 1993-  |e VerfasserIn  |0 (DE-588)1308032706  |0 (DE-627)1868850293  |4 aut 
700 1 |a Knoedler, Samuel  |d 1998-  |e VerfasserIn  |0 (DE-588)1286748313  |0 (DE-627)1843329697  |4 aut 
700 1 |a Kowalewski, Karl-Friedrich  |d 1989-  |e VerfasserIn  |0 (DE-588)1100724192  |0 (DE-627)859518825  |0 (DE-576)469770740  |4 aut 
700 1 |a Camplisson, I.  |e VerfasserIn  |4 aut 
700 1 |a Allers, Michael Martin  |d 2000-  |e VerfasserIn  |0 (DE-588)1365685160  |0 (DE-627)1925726134  |4 aut 
700 1 |a Dietrich, Maximilian  |d 1991-  |e VerfasserIn  |0 (DE-588)1172010889  |0 (DE-627)1040838707  |0 (DE-576)513949259  |4 aut 
700 1 |a Schmidt, Karsten  |d 1983-  |e VerfasserIn  |0 (DE-588)141624841  |0 (DE-627)63039475X  |0 (DE-576)324449690  |4 aut 
700 1 |a Salg, Gabriel Alexander  |d 1994-  |e VerfasserIn  |0 (DE-588)1200126661  |0 (DE-627)1682376370  |4 aut 
700 1 |a Kenngott, Hannes Götz  |d 1979-  |e VerfasserIn  |0 (DE-588)141469994  |0 (DE-627)62780117X  |0 (DE-576)324023065  |4 aut 
700 1 |a Billeter, Adrian  |d 1984-  |e VerfasserIn  |0 (DE-588)1071497499  |0 (DE-627)825950732  |0 (DE-576)433113804  |4 aut 
700 1 |a Gockel, I.  |e VerfasserIn  |4 aut 
700 1 |a Sagiv, C.  |e VerfasserIn  |4 aut 
700 1 |a Hadar, O. E.  |e VerfasserIn  |4 aut 
700 1 |a Gildenblat, J.  |e VerfasserIn  |4 aut 
700 1 |a Ayala, Leonardo  |d 1994-  |e VerfasserIn  |0 (DE-588)1254842977  |0 (DE-627)1797630938  |4 aut 
700 1 |a Seidlitz, Silvia  |e VerfasserIn  |0 (DE-588)1264853750  |0 (DE-627)1813743282  |4 aut 
700 1 |a Maier-Hein, Lena  |d 1980-  |e VerfasserIn  |0 (DE-588)1075029252  |0 (DE-627)832869899  |0 (DE-576)190090804  |4 aut 
700 1 |a Müller, Beat P.  |d 1971-  |e VerfasserIn  |0 (DE-588)14066209X  |0 (DE-627)70374819X  |0 (DE-576)317992287  |4 aut 
773 0 8 |i Enthalten in  |t European journal of surgical oncology  |d Burlington, Mass. : Harcourt, 1995  |g 51(2025), 1 vom: Jan., Artikel-ID 106908, Seite 1-13  |h Online-Ressource  |w (DE-627)320420361  |w (DE-600)2002481-2  |w (DE-576)103746862  |x 1532-2157  |7 nnas  |a Optimization of anastomotic technique and gastric conduit perfusion with hyperspectral imaging and machine learning in an experimental model for minimally invasive esophagectomy 
773 1 8 |g volume:51  |g year:2025  |g number:1  |g month:01  |g elocationid:106908  |g pages:1-13  |g extent:13  |a Optimization of anastomotic technique and gastric conduit perfusion with hyperspectral imaging and machine learning in an experimental model for minimally invasive esophagectomy 
856 4 0 |u https://doi.org/10.1016/j.ejso.2023.04.007  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0748798323004444  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20250513 
993 |a Article 
994 |a 2025 
998 |g 14066209X  |a Müller, Beat P.  |m 14066209X:Müller, Beat P.  |d 50000  |e 50000PM14066209X  |k 0/50000/  |p 22  |y j 
998 |g 1075029252  |a Maier-Hein, Lena  |m 1075029252:Maier-Hein, Lena  |d 910000  |d 910200  |e 910000PM1075029252  |e 910200PM1075029252  |k 0/910000/  |k 1/910000/910200/  |p 21 
998 |g 1264853750  |a Seidlitz, Silvia  |m 1264853750:Seidlitz, Silvia  |d 110000  |e 110000PS1264853750  |k 0/110000/  |p 20 
998 |g 1071497499  |a Billeter, Adrian  |m 1071497499:Billeter, Adrian  |d 50000  |e 50000PB1071497499  |k 0/50000/  |p 14 
998 |g 141469994  |a Kenngott, Hannes Götz  |m 141469994:Kenngott, Hannes Götz  |d 910000  |d 910200  |e 910000PK141469994  |e 910200PK141469994  |k 0/910000/  |k 1/910000/910200/  |p 13 
998 |g 1200126661  |a Salg, Gabriel Alexander  |m 1200126661:Salg, Gabriel Alexander  |d 910000  |d 910200  |e 910000PS1200126661  |e 910200PS1200126661  |k 0/910000/  |k 1/910000/910200/  |p 12 
998 |g 1172010889  |a Dietrich, Maximilian  |m 1172010889:Dietrich, Maximilian  |d 910000  |d 910300  |d 50000  |e 910000PD1172010889  |e 910300PD1172010889  |e 50000PD1172010889  |k 0/910000/  |k 1/910000/910300/  |k 0/50000/  |p 10 
998 |g 1365685160  |a Allers, Michael Martin  |m 1365685160:Allers, Michael Martin  |d 50000  |e 50000PA1365685160  |k 0/50000/  |p 9 
998 |g 1100724192  |a Kowalewski, Karl-Friedrich  |m 1100724192:Kowalewski, Karl-Friedrich  |d 60000  |d 63100  |e 60000PK1100724192  |e 63100PK1100724192  |k 0/60000/  |k 1/60000/63100/  |p 7 
998 |g 1286748313  |a Knoedler, Samuel  |m 1286748313:Knoedler, Samuel  |d 50000  |e 50000PK1286748313  |k 0/50000/  |p 6 
998 |g 1252285809  |a Özdemir, Berkin  |m 1252285809:Özdemir, Berkin  |d 50000  |e 50000PO1252285809  |k 0/50000/  |p 3 
998 |g 1196041105  |a Studier-Fischer, Alexander  |m 1196041105:Studier-Fischer, Alexander  |d 60000  |d 63100  |d 60000  |e 60000PS1196041105  |e 63100PS1196041105  |e 60000PS1196041105  |k 0/60000/  |k 1/60000/63100/  |k 0/60000/  |p 2 
998 |g 1067980059  |a Nickel, Felix  |m 1067980059:Nickel, Felix  |d 910000  |d 910200  |d 50000  |e 910000PN1067980059  |e 910200PN1067980059  |e 50000PN1067980059  |k 0/910000/  |k 1/910000/910200/  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN192544970X  |e 4723811788 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedDisp":"January 2025","dateIssuedKey":"2025"}],"relHost":[{"language":["eng"],"origin":[{"publisher":"Harcourt","dateIssuedKey":"1995","publisherPlace":"Burlington, Mass.","dateIssuedDisp":"1995-"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"part":{"pages":"1-13","extent":"13","year":"2025","volume":"51","issue":"1","text":"51(2025), 1 vom: Jan., Artikel-ID 106908, Seite 1-13"},"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 05.02.20"],"disp":"Optimization of anastomotic technique and gastric conduit perfusion with hyperspectral imaging and machine learning in an experimental model for minimally invasive esophagectomyEuropean journal of surgical oncology","id":{"zdb":["2002481-2"],"eki":["320420361"],"issn":["1532-2157"]},"title":[{"title":"European journal of surgical oncology","title_sort":"European journal of surgical oncology"}],"recId":"320420361","titleAlt":[{"title":"EJSO"}],"pubHistory":["Nachgewiesen 21.1995 -"]}],"person":[{"family":"Nickel","roleDisplay":"VerfasserIn","given":"Felix","role":"aut","display":"Nickel, Felix"},{"given":"Alexander","role":"aut","display":"Studier-Fischer, Alexander","roleDisplay":"VerfasserIn","family":"Studier-Fischer"},{"family":"Özdemir","roleDisplay":"VerfasserIn","display":"Özdemir, Berkin","role":"aut","given":"Berkin"},{"roleDisplay":"VerfasserIn","family":"Odenthal","given":"Jan","role":"aut","display":"Odenthal, Jan"},{"display":"Müller, Lucas-Raphael","role":"aut","given":"Lucas-Raphael","roleDisplay":"VerfasserIn","family":"Müller"},{"display":"Knoedler, Samuel","role":"aut","given":"Samuel","roleDisplay":"VerfasserIn","family":"Knoedler"},{"role":"aut","display":"Kowalewski, Karl-Friedrich","given":"Karl-Friedrich","family":"Kowalewski","roleDisplay":"VerfasserIn"},{"display":"Camplisson, I.","role":"aut","given":"I.","family":"Camplisson","roleDisplay":"VerfasserIn"},{"family":"Allers","roleDisplay":"VerfasserIn","role":"aut","display":"Allers, Michael Martin","given":"Michael Martin"},{"given":"Maximilian","display":"Dietrich, Maximilian","role":"aut","roleDisplay":"VerfasserIn","family":"Dietrich"},{"given":"Karsten","role":"aut","display":"Schmidt, Karsten","roleDisplay":"VerfasserIn","family":"Schmidt"},{"role":"aut","display":"Salg, Gabriel Alexander","given":"Gabriel Alexander","family":"Salg","roleDisplay":"VerfasserIn"},{"role":"aut","display":"Kenngott, Hannes Götz","given":"Hannes Götz","roleDisplay":"VerfasserIn","family":"Kenngott"},{"role":"aut","display":"Billeter, Adrian","given":"Adrian","family":"Billeter","roleDisplay":"VerfasserIn"},{"role":"aut","display":"Gockel, I.","given":"I.","family":"Gockel","roleDisplay":"VerfasserIn"},{"given":"C.","role":"aut","display":"Sagiv, C.","family":"Sagiv","roleDisplay":"VerfasserIn"},{"role":"aut","display":"Hadar, O. E.","given":"O. E.","roleDisplay":"VerfasserIn","family":"Hadar"},{"given":"J.","display":"Gildenblat, J.","role":"aut","roleDisplay":"VerfasserIn","family":"Gildenblat"},{"given":"Leonardo","role":"aut","display":"Ayala, Leonardo","family":"Ayala","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","family":"Seidlitz","display":"Seidlitz, Silvia","role":"aut","given":"Silvia"},{"display":"Maier-Hein, Lena","role":"aut","given":"Lena","family":"Maier-Hein","roleDisplay":"VerfasserIn"},{"display":"Müller, Beat P.","role":"aut","given":"Beat P.","family":"Müller","roleDisplay":"VerfasserIn"}],"physDesc":[{"extent":"13 S.","noteIll":"Illustrationen, Diagramme"}],"name":{"displayForm":["F. Nickel, A. Studier-Fischer, B. Özdemir, J. Odenthal, L.R. Müller, S. Knoedler, K.F. Kowalewski, I. Camplisson, M.M. Allers, M. Dietrich, K. Schmidt, G.A. Salg, H.G. Kenngott, A.T. Billeter, I. Gockel, C. Sagiv, O.E. Hadar, J. Gildenblat, L. Ayala, S. Seidlitz, L. Maier-Hein, B.P. Müller-Stich"]},"note":["Online verfügbar: 18. April 2023, Artikelversion: 14. Dezember 2024","Gesehen am 13.05.2025"],"title":[{"title":"Optimization of anastomotic technique and gastric conduit perfusion with hyperspectral imaging and machine learning in an experimental model for minimally invasive esophagectomy","title_sort":"Optimization of anastomotic technique and gastric conduit perfusion with hyperspectral imaging and machine learning in an experimental model for minimally invasive esophagectomy"}],"id":{"doi":["10.1016/j.ejso.2023.04.007"],"eki":["192544970X"]},"recId":"192544970X"} 
SRT |a NICKELFELIOPTIMIZATI2025