Comparison of different imaging devices and navigation systems for cervical pedicle screw placement: an experimental study on screw accuracy, screw placement time and radiation dose

Cervical pedicle screws (CPS) provide biomechanically superior fixation compared to other techniques but are technically more demanding. Navigated CPS placement has been increasingly reported as a safe and accurate technique, yet there are few studies comparing different combinations of imaging and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Mandelka, Leon Eric (VerfasserIn) , Wolf, Justine (VerfasserIn) , Medrow, Antonia (VerfasserIn) , Grützner, Paul Alfred (VerfasserIn) , Vetter, Sven Y. (VerfasserIn) , Gierse, Jula (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 12 November 2024
In: Scientific reports
Year: 2024, Jahrgang: 14, Pages: 1-10
ISSN:2045-2322
DOI:10.1038/s41598-024-77191-2
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1038/s41598-024-77191-2
Verlag, kostenfrei, Volltext: https://www.nature.com/articles/s41598-024-77191-2
Volltext
Verfasserangaben:Eric Mandelka, Justine Wolf, Antonia Medrow, Paul A. Gruetzner, Sven Y. Vetter & Jula Gierse

MARC

LEADER 00000caa a2200000 c 4500
001 1925470385
003 DE-627
005 20250717013459.0
007 cr uuu---uuuuu
008 250513s2024 xx |||||o 00| ||eng c
024 7 |a 10.1038/s41598-024-77191-2  |2 doi 
035 |a (DE-627)1925470385 
035 |a (DE-599)KXP1925470385 
035 |a (OCoLC)1528045373 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Mandelka, Leon Eric  |d 1993-  |e VerfasserIn  |0 (DE-588)1253523673  |0 (DE-627)1795729422  |4 aut 
245 1 0 |a Comparison of different imaging devices and navigation systems for cervical pedicle screw placement  |b an experimental study on screw accuracy, screw placement time and radiation dose  |c Eric Mandelka, Justine Wolf, Antonia Medrow, Paul A. Gruetzner, Sven Y. Vetter & Jula Gierse 
264 1 |c 12 November 2024 
300 |b Illustrationen 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 13.05.2025 
520 |a Cervical pedicle screws (CPS) provide biomechanically superior fixation compared to other techniques but are technically more demanding. Navigated CPS placement has been increasingly reported as a safe and accurate technique, yet there are few studies comparing different combinations of imaging and navigation systems under comparable conditions. With this study, we aimed to compare different imaging and navigation systems for CPS placement in terms of accuracy, screw placement time and applied radiation dose. For this experimental study, navigated CPS placement was performed at levels C2 to C7 in 24 identical radiopaque artificial spine models by two surgeons with different levels of experience using three different combinations of intraoperative 3D imaging devices and navigation systems. Accuracy, time and radiation dose were compared between the groups. In total, 288 screws were placed. Accuracy was > 98% in all groups with no significant differences between groups or between surgeons (P = 0.30 and P = 0.31, respectively), but the inexperienced surgeon required significantly more time (P < 0.001). Radiation dose was significantly higher with iCT compared to CBCT (P < 0.0001). Under experimental conditions, accuracy rates of > 98% were achieved for navigated CPS placement regardless of the imaging modality or navigation system used. Radiation doses were significantly lower for CBCT compared to iCT guidance. 
650 4 |a Bone 
650 4 |a Bone imaging 
650 4 |a Experimental models of disease 
650 4 |a Fracture repair 
650 4 |a Three-dimensional imaging 
650 4 |a Trauma 
700 1 |a Wolf, Justine  |e VerfasserIn  |0 (DE-588)1365438260  |0 (DE-627)1925471519  |4 aut 
700 1 |a Medrow, Antonia  |e VerfasserIn  |0 (DE-588)1365438767  |0 (DE-627)1925472167  |4 aut 
700 1 |a Grützner, Paul Alfred  |d 1962-  |e VerfasserIn  |0 (DE-588)111926688  |0 (DE-627)728553473  |0 (DE-576)372572863  |4 aut 
700 1 |a Vetter, Sven Y.  |d 1977-  |e VerfasserIn  |0 (DE-588)13390444X  |0 (DE-627)557959306  |0 (DE-576)300182740  |4 aut 
700 1 |a Gierse, Jula  |d 1995-  |e VerfasserIn  |0 (DE-588)130882761X  |0 (DE-627)1869403142  |4 aut 
773 0 8 |i Enthalten in  |t Scientific reports  |d [London] : Springer Nature, 2011  |g 14(2024), Artikel-ID 27759, Seite 1-10  |h Online-Ressource  |w (DE-627)663366712  |w (DE-600)2615211-3  |w (DE-576)346641179  |x 2045-2322  |7 nnas  |a Comparison of different imaging devices and navigation systems for cervical pedicle screw placement an experimental study on screw accuracy, screw placement time and radiation dose 
773 1 8 |g volume:14  |g year:2024  |g elocationid:27759  |g pages:1-10  |g extent:10  |a Comparison of different imaging devices and navigation systems for cervical pedicle screw placement an experimental study on screw accuracy, screw placement time and radiation dose 
856 4 0 |u https://doi.org/10.1038/s41598-024-77191-2  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.nature.com/articles/s41598-024-77191-2  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20250513 
993 |a Article 
994 |a 2024 
998 |g 13390444X  |a Vetter, Sven Y.  |m 13390444X:Vetter, Sven Y.  |d 50000  |e 50000PV13390444X  |k 0/50000/  |p 5 
998 |g 111926688  |a Grützner, Paul Alfred  |m 111926688:Grützner, Paul Alfred  |d 50000  |e 50000PG111926688  |k 0/50000/  |p 4 
998 |g 1365438767  |a Medrow, Antonia  |m 1365438767:Medrow, Antonia  |d 50000  |e 50000PM1365438767  |k 0/50000/  |p 3 
998 |g 1365438260  |a Wolf, Justine  |m 1365438260:Wolf, Justine  |d 50000  |e 50000PW1365438260  |k 0/50000/  |p 2 
999 |a KXP-PPN1925470385  |e 4723839283 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"note":["Gesehen am 13.05.2025"],"recId":"1925470385","physDesc":[{"noteIll":"Illustrationen","extent":"10 S."}],"relHost":[{"type":{"media":"Online-Ressource","bibl":"periodical"},"physDesc":[{"extent":"Online-Ressource"}],"recId":"663366712","note":["Gesehen am 12.07.24"],"id":{"zdb":["2615211-3"],"issn":["2045-2322"],"eki":["663366712"]},"part":{"pages":"1-10","volume":"14","extent":"10","text":"14(2024), Artikel-ID 27759, Seite 1-10","year":"2024"},"origin":[{"publisher":"Springer Nature ; Nature Publishing Group","dateIssuedKey":"2011","publisherPlace":"[London] ; London","dateIssuedDisp":"2011-"}],"disp":"Comparison of different imaging devices and navigation systems for cervical pedicle screw placement an experimental study on screw accuracy, screw placement time and radiation doseScientific reports","title":[{"title_sort":"Scientific reports","title":"Scientific reports"}],"pubHistory":["1, article number 1 (2011)-"],"language":["eng"]}],"title":[{"subtitle":"an experimental study on screw accuracy, screw placement time and radiation dose","title_sort":"Comparison of different imaging devices and navigation systems for cervical pedicle screw placement","title":"Comparison of different imaging devices and navigation systems for cervical pedicle screw placement"}],"name":{"displayForm":["Eric Mandelka, Justine Wolf, Antonia Medrow, Paul A. Gruetzner, Sven Y. Vetter & Jula Gierse"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"doi":["10.1038/s41598-024-77191-2"],"eki":["1925470385"]},"person":[{"family":"Mandelka","role":"aut","display":"Mandelka, Leon Eric","given":"Leon Eric"},{"given":"Justine","family":"Wolf","display":"Wolf, Justine","role":"aut"},{"role":"aut","display":"Medrow, Antonia","family":"Medrow","given":"Antonia"},{"given":"Paul Alfred","family":"Grützner","role":"aut","display":"Grützner, Paul Alfred"},{"family":"Vetter","display":"Vetter, Sven Y.","role":"aut","given":"Sven Y."},{"given":"Jula","display":"Gierse, Jula","role":"aut","family":"Gierse"}],"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"12 November 2024"}]} 
SRT |a MANDELKALECOMPARISON1220