Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 Tesla: initial results [data]

Glomerular filtration rate (GFR) is an essential parameter of kidney function which can be measured by dynamic contrast enhanced magnetic resonance imaging (MRI-GFR) and transcutaneous approaches based on fluorescent tracer molecules (optical-GFR). In an initial study comparing both techniques in se...

Full description

Saved in:
Bibliographic Details
Main Author: Zöllner, Frank G. (Author)
Format: Database Research Data
Language:English
Published: Heidelberg Universität 2025-04-28
DOI:10.11588/DATA/MEUQDI
Subjects:
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.11588/DATA/MEUQDI
Verlag, kostenfrei, Volltext: https://heidata.uni-heidelberg.de/dataset.xhtml?persistentId=doi:10.11588/DATA/MEUQDI
Get full text
Author Notes:Frank Zoellner

MARC

LEADER 00000nmi a2200000 c 4500
001 1925912272
003 DE-627
005 20250519092203.0
006 su| d|o |0 |0
007 cr uuu---uuuuu
008 250519c20259999xx |o | eng c
024 7 |a 10.11588/DATA/MEUQDI  |2 doi 
035 |a (DE-627)1925912272 
035 |a (DE-599)KXP1925912272 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Zöllner, Frank G.  |d 1976-  |e VerfasserIn  |0 (DE-588)129580015  |0 (DE-627)473357054  |0 (DE-576)297732587  |4 aut 
245 1 0 |a Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 Tesla  |b initial results [data]  |c Frank Zoellner 
264 1 |a Heidelberg  |b Universität  |c 2025-04-28 
300 |a 1 Online-Ressource (25 Files) 
336 |a Text  |b txt  |2 rdacontent 
336 |a Computerdaten  |b cod  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 19.05.2025 
520 |a Glomerular filtration rate (GFR) is an essential parameter of kidney function which can be measured by dynamic contrast enhanced magnetic resonance imaging (MRI-GFR) and transcutaneous approaches based on fluorescent tracer molecules (optical-GFR). In an initial study comparing both techniques in separate measurements on the same animal, the correlation of the obtained GFR was poor. The goal of this study was to investigate if a simultaneous measurement was feasible and if thereby, the discrepancies in MRI-GFR and optical-GFR could be reduced. For the experiments healthy and unilateral nephrectomised (UNX) Sprague Dawley (SD) rats were used. The miniaturized fluorescent sensor was fixed on the depilated back of an anesthetized rat. A bolus of 5 mg/100 g b.w. of FITC-sinistrin was intravenously injected. For dynamic contrast enhanced perfusion imaging (DCE-MRI) a 3D time-resolved angiography with stochastic trajectories (TWIST) sequence was used. By means of a one compartment model the excretion half-life (t1/2) of FITC-sinistrin was calculated and converted into GFR. GFR from DCE-MRI was calculated by fitting pixel-wise a two compartment renal filtration model. Mean cortical GFR and GFR by FITC-sinistrin were compared by Bland-Altman plots and pair-wise t-test. Results show that a simultaneous GFR measurement using both techniques is feasible. Mean optical-GFR was 4.34±2.22 ml/min (healthy SD rats) and 2.34±0.90 ml/min (UNX rats) whereas MRI-GFR was 2.10±0.64 ml/min (SD rats) and 1.17±0.38 ml/min (UNX rats). Differences between healthy and UNX rats were significant (p<0.05) and almost equal percentage difference (46.1% and 44.3%) in mean GFR were assessed with both techniques. Overall mean optical-GFR values were approximately twice as high compared to MRI-GFR values. However, compared to a previous study, our results showed a higher agreement. In conclusion, the possibility to use the transcutaneous method in MRI may have a huge impact in improving and validating MRI methods for GFR assessment in animal models. 
650 4 |a Health and Life Sciences 
650 4 |a Medicine 
655 7 |a Forschungsdaten  |0 (DE-588)1098579690  |0 (DE-627)857755366  |0 (DE-576)469182156  |2 gnd-content 
655 7 |a Datenbank  |0 (DE-588)4011119-2  |0 (DE-627)106354256  |0 (DE-576)208891943  |2 gnd-content 
787 0 8 |i Forschungsdaten zu  |t Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 tesla  |d 2013  |w (DE-627)1471653080  |w (DE-576)401653080 
856 4 0 |u https://doi.org/10.11588/DATA/MEUQDI  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://heidata.uni-heidelberg.de/dataset.xhtml?persistentId=doi:10.11588/DATA/MEUQDI  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a BO 
992 |a 20250519 
993 |a ResearchData 
994 |a 2025 
998 |g 129580015  |a Zöllner, Frank G.  |m 129580015:Zöllner, Frank G.  |d 60000  |d 65200  |d 60000  |e 60000PZ129580015  |e 65200PZ129580015  |e 60000PZ129580015  |k 0/60000/  |k 1/60000/65200/  |k 0/60000/  |p 1  |x j  |y j 
999 |a KXP-PPN1925912272  |e 4725695467 
BIB |a Y 
JSO |a {"type":{"media":"Online-Ressource","bibl":"dataset"},"origin":[{"publisherPlace":"Heidelberg","dateIssuedDisp":"2025-04-28","dateIssuedKey":"2025","publisher":"Universität"}],"note":["Gesehen am 19.05.2025"],"title":[{"title":"Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 Tesla","subtitle":"initial results [data]","title_sort":"Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 Tesla"}],"person":[{"role":"aut","given":"Frank G.","family":"Zöllner","display":"Zöllner, Frank G."}],"id":{"doi":["10.11588/DATA/MEUQDI"],"eki":["1925912272"]},"language":["eng"],"name":{"displayForm":["Frank Zoellner"]},"physDesc":[{"extent":"1 Online-Ressource (25 Files)"}],"recId":"1925912272"} 
SRT |a ZOELLNERFRSIMULTANEO2025