Reflex Xpert MTB/XDR testing of residual Rifampicin-resistant specimens: a clinical laboratory-based diagnostic accuracy and feasibility study in South Africa

The World Health Organization-approved Xpert MTB/XDR test detects Mycobacterium tuberculosis and resistance to isoniazid, fluoroquinolones, ethionamide, and injectable drugs directly in specimens. This pragmatic, laboratory-based study assessed the diagnostic accuracy and feasibility of a reflex tes...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Centner, Chad (VerfasserIn) , Munir, R (VerfasserIn) , Tagliani, E (VerfasserIn) , Rieß, F (VerfasserIn) , Brown, P (VerfasserIn) , Hayes, C (VerfasserIn) , Dolby, T (VerfasserIn) , Zemanay, W (VerfasserIn) , Cirillo, D M (VerfasserIn) , David, A (VerfasserIn) , Schumacher, S G (VerfasserIn) , Denkinger, Claudia M. (VerfasserIn) , Ruhwald, M (VerfasserIn) , Leukes, V N (VerfasserIn) , Nicol, M P (VerfasserIn) , Van der Walt, I (VerfasserIn) , Kisten, G (VerfasserIn) , Gumede, M (VerfasserIn) , Mace, A (VerfasserIn) , Brink, A (VerfasserIn) , Stevens, W (VerfasserIn) , Scott, L (VerfasserIn) , Penn-Nicholson, A (VerfasserIn) , Cox, H (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: August 2024
In: Open Forum Infectious Diseases
Year: 2024, Jahrgang: 11, Heft: 8, Pages: 1-10
ISSN:2328-8957
DOI:10.1093/ofid/ofae437
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1093/ofid/ofae437
Volltext
Verfasserangaben:C.M. Centner, R. Munir, E. Tagliani, F. Rieß, P. Brown, C. Hayes, T. Dolby, W. Zemanay, D.M. Cirillo, A. David, S.G. Schumacher, C.M. Denkinger, M. Ruhwald, V.N. Leukes, M.P. Nicol, I. Van der Walt, G. Kisten, M. Gumede, A. Mace, A. Brink, W. Stevens, L. Scott, A. Penn-Nicholson, H. Cox, on behalf of the TB-CAPT Consortium

MARC

LEADER 00000naa a2200000 c 4500
001 1930199813
003 DE-627
005 20250710113659.0
007 cr uuu---uuuuu
008 250710s2024 xx |||||o 00| ||eng c
024 7 |a 10.1093/ofid/ofae437  |2 doi 
035 |a (DE-627)1930199813 
035 |a (DE-599)KXP1930199813 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 32  |2 sdnb 
100 1 |a Centner, Chad  |e VerfasserIn  |0 (DE-588)1371129754  |0 (DE-627)1930200552  |4 aut 
245 1 0 |a Reflex Xpert MTB/XDR testing of residual Rifampicin-resistant specimens  |b a clinical laboratory-based diagnostic accuracy and feasibility study in South Africa  |c C.M. Centner, R. Munir, E. Tagliani, F. Rieß, P. Brown, C. Hayes, T. Dolby, W. Zemanay, D.M. Cirillo, A. David, S.G. Schumacher, C.M. Denkinger, M. Ruhwald, V.N. Leukes, M.P. Nicol, I. Van der Walt, G. Kisten, M. Gumede, A. Mace, A. Brink, W. Stevens, L. Scott, A. Penn-Nicholson, H. Cox, on behalf of the TB-CAPT Consortium 
264 1 |c August 2024 
300 |b Illustrationen 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Veröffentlicht: 31. Juli 2024 
500 |a Gesehen am 10.07.2025 
520 |a The World Health Organization-approved Xpert MTB/XDR test detects Mycobacterium tuberculosis and resistance to isoniazid, fluoroquinolones, ethionamide, and injectable drugs directly in specimens. This pragmatic, laboratory-based study assessed the diagnostic accuracy and feasibility of a reflex testing approach, where Xpert MTB/XDR was performed on residual specimens previously processed for Xpert MTB/RIF Ultra.Routine respiratory specimens, processed for Xpert MTB/RIF Ultra, were stored in sample reagent buffer at 2°C-8°C. If rifampicin resistant, the residual specimen was assessed for adequate volume (≥2 mL) and tested with Xpert MTB/XDR, with storage time recorded. A second specimen was used for routine and reference standard testing (culture and sequencing).Specimens (99% sputum) from 763 participants submitted to 2 large routine laboratories were included. Xpert MTB/XDR yielded valid resistance detection results in 639 (84%), compared with 507 (66%) for routine testing (difference [95% CI], 18% [13%-22%]). The median turnaround time for results was 23 hours for Xpert MTB/XDR and 15 days for routine testing. While 748 specimens (98%) were ≥2 mL, only 102 (13%) were stored for ≤4 hours. By the reference standard, 284 of 394 (72%) were isoniazid resistant, and 57 of 380 (15%) were fluroquinolone resistant. The sensitivities of Xpert MTB/XDR were 94% (95% CI, 91%-97%) for isoniazid and 91% (81%-97%) for fluoroquinolone resistance detection. The specificities were 98% (94%-100%) and 100% (98%-100%), respectively.Xpert MTB/XDR performed favorably compared with the reference, and the reflex testing approach increased results availability over routine testing, while dramatically decreasing turnaround time from weeks to hours. Laboratory workflow precluded testing within the manufacturer-recommended 4-hour storage time, but longer storage did not appear detrimental. 
700 1 |a Munir, R  |e VerfasserIn  |4 aut 
700 1 |a Tagliani, E  |e VerfasserIn  |4 aut 
700 1 |a Rieß, F  |e VerfasserIn  |4 aut 
700 1 |a Brown, P  |e VerfasserIn  |4 aut 
700 1 |a Hayes, C  |e VerfasserIn  |4 aut 
700 1 |a Dolby, T  |e VerfasserIn  |4 aut 
700 1 |a Zemanay, W  |e VerfasserIn  |4 aut 
700 1 |a Cirillo, D M  |e VerfasserIn  |4 aut 
700 1 |a David, A  |e VerfasserIn  |4 aut 
700 1 |a Schumacher, S G  |e VerfasserIn  |4 aut 
700 1 |a Denkinger, Claudia M.  |d 1978-  |e VerfasserIn  |0 (DE-588)131597701  |0 (DE-627)511279469  |0 (DE-576)298613727  |4 aut 
700 1 |a Ruhwald, M  |e VerfasserIn  |4 aut 
700 1 |a Leukes, V N  |e VerfasserIn  |4 aut 
700 1 |a Nicol, M P  |e VerfasserIn  |4 aut 
700 1 |a Van der Walt, I  |e VerfasserIn  |4 aut 
700 1 |a Kisten, G  |e VerfasserIn  |4 aut 
700 1 |a Gumede, M  |e VerfasserIn  |4 aut 
700 1 |a Mace, A  |e VerfasserIn  |4 aut 
700 1 |a Brink, A  |e VerfasserIn  |4 aut 
700 1 |a Stevens, W  |e VerfasserIn  |4 aut 
700 1 |a Scott, L  |e VerfasserIn  |4 aut 
700 1 |a Penn-Nicholson, A  |e VerfasserIn  |4 aut 
700 1 |a Cox, H  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Open Forum Infectious Diseases  |d Oxford : Oxford University Press, 2014  |g 11(2024), 8 vom: Aug., Artikel-ID ofae437, Seite 1-10  |h Online-Ressource  |w (DE-627)779394089  |w (DE-600)2757767-3  |w (DE-576)401709566  |x 2328-8957  |7 nnas  |a Reflex Xpert MTB/XDR testing of residual Rifampicin-resistant specimens a clinical laboratory-based diagnostic accuracy and feasibility study in South Africa 
773 1 8 |g volume:11  |g year:2024  |g number:8  |g month:08  |g elocationid:ofae437  |g pages:1-10  |g extent:10  |a Reflex Xpert MTB/XDR testing of residual Rifampicin-resistant specimens a clinical laboratory-based diagnostic accuracy and feasibility study in South Africa 
856 4 0 |u https://doi.org/10.1093/ofid/ofae437  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20250710 
993 |a Article 
994 |a 2024 
998 |g 131597701  |a Denkinger, Claudia M.  |m 131597701:Denkinger, Claudia M.  |d 910000  |d 911700  |d 50000  |e 910000PD131597701  |e 911700PD131597701  |e 50000PD131597701  |k 0/910000/  |k 1/910000/911700/  |k 0/50000/  |p 12 
999 |a KXP-PPN1930199813  |e 4744545106 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Veröffentlicht: 31. Juli 2024","Gesehen am 10.07.2025"],"relHost":[{"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 07.08.2020"],"pubHistory":["2014 -"],"physDesc":[{"extent":"Online-Ressource"}],"language":["eng"],"title":[{"title":"Open Forum Infectious Diseases","title_sort":"Open Forum Infectious Diseases"}],"recId":"779394089","disp":"Reflex Xpert MTB/XDR testing of residual Rifampicin-resistant specimens a clinical laboratory-based diagnostic accuracy and feasibility study in South AfricaOpen Forum Infectious Diseases","id":{"issn":["2328-8957"],"zdb":["2757767-3"],"eki":["779394089"]},"origin":[{"publisherPlace":"Oxford","dateIssuedDisp":"2014-","publisher":"Oxford University Press","dateIssuedKey":"2014"}],"part":{"year":"2024","issue":"8","volume":"11","pages":"1-10","text":"11(2024), 8 vom: Aug., Artikel-ID ofae437, Seite 1-10","extent":"10"}}],"person":[{"given":"Chad","role":"aut","family":"Centner","display":"Centner, Chad"},{"display":"Munir, R","given":"R","role":"aut","family":"Munir"},{"display":"Tagliani, E","family":"Tagliani","role":"aut","given":"E"},{"family":"Rieß","role":"aut","given":"F","display":"Rieß, F"},{"display":"Brown, P","role":"aut","given":"P","family":"Brown"},{"family":"Hayes","given":"C","role":"aut","display":"Hayes, C"},{"role":"aut","given":"T","family":"Dolby","display":"Dolby, T"},{"given":"W","role":"aut","family":"Zemanay","display":"Zemanay, W"},{"family":"Cirillo","given":"D M","role":"aut","display":"Cirillo, D M"},{"role":"aut","given":"A","family":"David","display":"David, A"},{"family":"Schumacher","role":"aut","given":"S G","display":"Schumacher, S G"},{"display":"Denkinger, Claudia M.","family":"Denkinger","role":"aut","given":"Claudia M."},{"display":"Ruhwald, M","given":"M","role":"aut","family":"Ruhwald"},{"role":"aut","given":"V N","family":"Leukes","display":"Leukes, V N"},{"display":"Nicol, M P","family":"Nicol","role":"aut","given":"M P"},{"family":"Van der Walt","given":"I","role":"aut","display":"Van der Walt, I"},{"display":"Kisten, G","family":"Kisten","role":"aut","given":"G"},{"display":"Gumede, M","family":"Gumede","given":"M","role":"aut"},{"family":"Mace","role":"aut","given":"A","display":"Mace, A"},{"role":"aut","given":"A","family":"Brink","display":"Brink, A"},{"role":"aut","given":"W","family":"Stevens","display":"Stevens, W"},{"display":"Scott, L","family":"Scott","given":"L","role":"aut"},{"given":"A","role":"aut","family":"Penn-Nicholson","display":"Penn-Nicholson, A"},{"display":"Cox, H","family":"Cox","given":"H","role":"aut"}],"title":[{"title_sort":"Reflex Xpert MTB/XDR testing of residual Rifampicin-resistant specimens","title":"Reflex Xpert MTB/XDR testing of residual Rifampicin-resistant specimens","subtitle":"a clinical laboratory-based diagnostic accuracy and feasibility study in South Africa"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"physDesc":[{"noteIll":"Illustrationen","extent":"10 S."}],"id":{"eki":["1930199813"],"doi":["10.1093/ofid/ofae437"]},"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"August 2024"}],"name":{"displayForm":["C.M. Centner, R. Munir, E. Tagliani, F. Rieß, P. Brown, C. Hayes, T. Dolby, W. Zemanay, D.M. Cirillo, A. David, S.G. Schumacher, C.M. Denkinger, M. Ruhwald, V.N. Leukes, M.P. Nicol, I. Van der Walt, G. Kisten, M. Gumede, A. Mace, A. Brink, W. Stevens, L. Scott, A. Penn-Nicholson, H. Cox, on behalf of the TB-CAPT Consortium"]},"recId":"1930199813"} 
SRT |a CENTNERCHAREFLEXXPER2024