Water phase transition and signal nulling in 3D dual-echo adiabatic inversion-recovery UTE (IR-UTE) imaging of myelin

Purpose The semisolid myelin sheath has very fast transverse relaxation and is invisible to conventional MRI sequences. UTE sequences can detect signal from myelin. The major challenge is the concurrent detection of various water components. Methods The inversion recovery (IR)-based UTE (IR-UTE) seq...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Athertya, Jiyo S. (VerfasserIn) , Shin, Soo Hyun (VerfasserIn) , Malhi, Bhavsimran Singh (VerfasserIn) , Lo, James (VerfasserIn) , Sedaghat, Sam (VerfasserIn) , Jang, Hyungseok (VerfasserIn) , Ma, Yajun (VerfasserIn) , Du, Jiang (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: December 2024
In: Magnetic resonance in medicine
Year: 2024, Jahrgang: 92, Heft: 6, Pages: 2464-2472
ISSN:1522-2594
DOI:10.1002/mrm.30243
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1002/mrm.30243
Verlag, lizenzpflichtig, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.30243
Volltext
Verfasserangaben:Jiyo S. Athertya, Soo Hyun Shin, Bhavsimran Singh Malhi, James Lo, Sam Sedaghat, Hyungseok Jang, Yajun Ma, Jiang Du

MARC

LEADER 00000naa a2200000 c 4500
001 1930407742
003 DE-627
005 20250714092704.0
007 cr uuu---uuuuu
008 250714s2024 xx |||||o 00| ||eng c
024 7 |a 10.1002/mrm.30243  |2 doi 
035 |a (DE-627)1930407742 
035 |a (DE-599)KXP1930407742 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Athertya, Jiyo S.  |e VerfasserIn  |0 (DE-588)1371458847  |0 (DE-627)1930408218  |4 aut 
245 1 0 |a Water phase transition and signal nulling in 3D dual-echo adiabatic inversion-recovery UTE (IR-UTE) imaging of myelin  |c Jiyo S. Athertya, Soo Hyun Shin, Bhavsimran Singh Malhi, James Lo, Sam Sedaghat, Hyungseok Jang, Yajun Ma, Jiang Du 
264 1 |c December 2024 
300 |b Illustrationen 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Erstveröffentlichung: 9. August 2024 
500 |a Gesehen am 14.07.2025 
520 |a Purpose The semisolid myelin sheath has very fast transverse relaxation and is invisible to conventional MRI sequences. UTE sequences can detect signal from myelin. The major challenge is the concurrent detection of various water components. Methods The inversion recovery (IR)-based UTE (IR-UTE) sequence employs an adiabatic inversion pulse to invert and suppress water magnetizations. TI plays a key role in water suppression, with negative water magnetizations (negative phase) before the null point and positive water magnetizations (positive phase) after the null point. A series of dual-echo IR-UTE images were acquired with different TIs to detect water phase transition. The effects of TR in phase transition and water suppression were also investigated using a relatively long TR of 500 ms and a short TR of 106 ms. The water phase transition in dual-echo IR-UTE imaging of myelin was investigated in five ex vivo and five in vivo human brains. Results An apparent phase transition was observed in the second echo at the water signal null point, where the myelin signal was selectively detected by the UTE data acquisition at the optimal TI. The water phase transition point varied significantly across the brain when the long TR of 500 ms was used, whereas the convergence of TIs was observed when the short TR of 106 ms was used. Conclusion The results suggest that the IR-UTE sequence with a short TR allows uniform inversion and nulling of water magnetizations, thereby providing volumetric imaging of myelin. 
650 4 |a MRI 
650 4 |a myelin 
650 4 |a phase transition 
650 4 |a UTE 
650 4 |a white matter 
700 1 |a Shin, Soo Hyun  |e VerfasserIn  |4 aut 
700 1 |a Malhi, Bhavsimran Singh  |e VerfasserIn  |4 aut 
700 1 |a Lo, James  |e VerfasserIn  |4 aut 
700 1 |a Sedaghat, Sam  |d 1986-  |e VerfasserIn  |0 (DE-588)1074259270  |0 (DE-627)831927860  |0 (DE-576)441954480  |4 aut 
700 1 |a Jang, Hyungseok  |e VerfasserIn  |4 aut 
700 1 |a Ma, Yajun  |e VerfasserIn  |4 aut 
700 1 |a Du, Jiang  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in medicine  |d New York, NY [u.a.] : Wiley-Liss, 1984  |g 92(2024), 6 vom: Dez., Seite 2464-2472  |h Online-Ressource  |w (DE-627)303257040  |w (DE-600)1493786-4  |w (DE-576)096290455  |x 1522-2594  |7 nnas  |a Water phase transition and signal nulling in 3D dual-echo adiabatic inversion-recovery UTE (IR-UTE) imaging of myelin 
773 1 8 |g volume:92  |g year:2024  |g number:6  |g month:12  |g pages:2464-2472  |g extent:9  |a Water phase transition and signal nulling in 3D dual-echo adiabatic inversion-recovery UTE (IR-UTE) imaging of myelin 
856 4 0 |u https://doi.org/10.1002/mrm.30243  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.30243  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20250714 
993 |a Article 
994 |a 2024 
998 |g 1074259270  |a Sedaghat, Sam  |m 1074259270:Sedaghat, Sam  |d 910000  |d 911400  |d 50000  |e 910000PS1074259270  |e 911400PS1074259270  |e 50000PS1074259270  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 5 
999 |a KXP-PPN1930407742  |e 474594280X 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"person":[{"role":"aut","given":"Jiyo S.","family":"Athertya","display":"Athertya, Jiyo S."},{"family":"Shin","display":"Shin, Soo Hyun","role":"aut","given":"Soo Hyun"},{"family":"Malhi","display":"Malhi, Bhavsimran Singh","given":"Bhavsimran Singh","role":"aut"},{"display":"Lo, James","family":"Lo","role":"aut","given":"James"},{"display":"Sedaghat, Sam","family":"Sedaghat","given":"Sam","role":"aut"},{"display":"Jang, Hyungseok","family":"Jang","given":"Hyungseok","role":"aut"},{"role":"aut","given":"Yajun","display":"Ma, Yajun","family":"Ma"},{"family":"Du","display":"Du, Jiang","role":"aut","given":"Jiang"}],"id":{"doi":["10.1002/mrm.30243"],"eki":["1930407742"]},"name":{"displayForm":["Jiyo S. Athertya, Soo Hyun Shin, Bhavsimran Singh Malhi, James Lo, Sam Sedaghat, Hyungseok Jang, Yajun Ma, Jiang Du"]},"physDesc":[{"noteIll":"Illustrationen","extent":"9 S."}],"recId":"1930407742","relHost":[{"language":["eng"],"titleAlt":[{"title":"MRM"}],"part":{"extent":"9","volume":"92","year":"2024","pages":"2464-2472","text":"92(2024), 6 vom: Dez., Seite 2464-2472","issue":"6"},"origin":[{"publisherPlace":"New York, NY [u.a.]","dateIssuedKey":"1984","publisher":"Wiley-Liss","dateIssuedDisp":"1984-"}],"note":["Gesehen am 28.02.08"],"pubHistory":["1.1984 -"],"title":[{"subtitle":"MRM ; an official journal of the International Society for Magnetic Resonance in Medicine","title_sort":"Magnetic resonance in medicine","title":"Magnetic resonance in medicine"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Water phase transition and signal nulling in 3D dual-echo adiabatic inversion-recovery UTE (IR-UTE) imaging of myelinMagnetic resonance in medicine","physDesc":[{"extent":"Online-Ressource"}],"recId":"303257040","id":{"eki":["303257040"],"doi":["10.1002/(ISSN)1522-2594"],"issn":["1522-2594"],"zdb":["1493786-4"]}}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Erstveröffentlichung: 9. August 2024","Gesehen am 14.07.2025"],"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"December 2024"}],"title":[{"title":"Water phase transition and signal nulling in 3D dual-echo adiabatic inversion-recovery UTE (IR-UTE) imaging of myelin","title_sort":"Water phase transition and signal nulling in 3D dual-echo adiabatic inversion-recovery UTE (IR-UTE) imaging of myelin"}]} 
SRT |a ATHERTYAJIWATERPHASE2024