Elevated blood tantalum concentrations in patients following reconstruction of severe acetabular defects in total hip arthroplasty using modular tantalum augments in combination with uncemented tantalum cups
Background - The reconstruction of acetabular defects in total hip arthroplasty (THA) can be challenging. An option to treat uncontained acetabular defects is to use modular tantalum augments in combination with cementless press-fit cups. However, modularity is associated with an increased risk of d...
Gespeichert in:
| Hauptverfasser: | , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
31 May 2024
|
| In: |
The journal of arthroplasty
Year: 2025, Jahrgang: 40, Heft: 2, Pages: 467-474 |
| ISSN: | 1532-8406 |
| DOI: | 10.1016/j.arth.2024.05.068 |
| Online-Zugang: | Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.arth.2024.05.068 Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S0883540324005400 |
| Verfasserangaben: | David Spranz, Lisa-Marie Müller, Raphael Trefzer, Pit Hetto, Moritz Innmann, Tobias Renkawitz, Tilman Walker, Tobias Reiner |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1931625743 | ||
| 003 | DE-627 | ||
| 005 | 20250814140235.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 250723s2024 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.arth.2024.05.068 |2 doi | |
| 035 | |a (DE-627)1931625743 | ||
| 035 | |a (DE-599)KXP1931625743 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Spranz, David Maximilian |d 1987- |e VerfasserIn |0 (DE-588)1045003727 |0 (DE-627)773387056 |0 (DE-576)398315779 |4 aut | |
| 245 | 1 | 0 | |a Elevated blood tantalum concentrations in patients following reconstruction of severe acetabular defects in total hip arthroplasty using modular tantalum augments in combination with uncemented tantalum cups |c David Spranz, Lisa-Marie Müller, Raphael Trefzer, Pit Hetto, Moritz Innmann, Tobias Renkawitz, Tilman Walker, Tobias Reiner |
| 264 | 1 | |c 31 May 2024 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 23.07.2025 | ||
| 520 | |a Background - The reconstruction of acetabular defects in total hip arthroplasty (THA) can be challenging. An option to treat uncontained acetabular defects is to use modular tantalum augments in combination with cementless press-fit cups. However, modularity is associated with an increased risk of debonding and mechanical failure. In addition, metal wear particles can be released due to micromotions at the implant interface. Clinical data on the long-term results of this treatment strategy is limited. The purposes of this study were: (1) to evaluate the clinical and radiological outcome of complex THA using modular trabecular metal augments and uncemented revision cups; (2) to investigate the blood tantalum concentrations in these patients at mid-term (mean 4.5 year) follow-up; and (3) to report complications and mechanisms of failure related to this procedure. - Methods - In this single-center study, we retrospectively reviewed data from a consecutive cohort of 27 patients who underwent complex acetabular defect reconstruction using a modular tantalum acetabular augment in combination with an uncemented tantalum cup. We evaluated the implant survival, and the radiological and clinical outcomes after a mean follow-up of 4.5 years (standard deviation 2.1; range 2.5 to 10.6 years) using patient-reported outcome scores. Blood samples were analyzed regarding tantalum concentration and compared with a control group. - Results - The cumulative survival rate at 4.5 years with the end point “revision of the acetabular component for aseptic loosening” was 94.4% (95% confidence interval [CI] 71.6 to 99.2) and 82.9% (95% CI 60.5 to 93.3) for the end point “revision for any reason.” The patient-reported outcome scores improved significantly up to the latest follow-up, and radiographic data showed no signs of loosening or implant migration. Median blood tantalum concentrations were significantly higher in the study group (0.15 μg/L) compared to the control group (0.002 μg/L) (P < .001). - Conclusions - This study demonstrated acceptable clinical and radiological results of cementless revision THA using modular trabecular metal implants for the reconstruction of large acetabular defects. Tantalum concentrations were significantly higher in patients who had tantalum implants compared to the control group; however, the systemic and local effects of an increased tantalum exposure are not yet fully understood and have to be further investigated. | ||
| 650 | 4 | |a acetabular defect reconstruction | |
| 650 | 4 | |a hip revision | |
| 650 | 4 | |a modularity | |
| 650 | 4 | |a tantalum blood concentration | |
| 650 | 4 | |a tantalum trabecular metal augments | |
| 650 | 4 | |a total hip arthroplasty | |
| 700 | 1 | |a Müller, Lisa-Marie |d 1997- |e VerfasserIn |0 (DE-588)1373842113 |0 (DE-627)1933241209 |4 aut | |
| 700 | 1 | |a Trefzer, Raphael |e VerfasserIn |0 (DE-588)126160217X |0 (DE-627)1808796861 |4 aut | |
| 700 | 1 | |a Hetto, Pit |d 1991- |e VerfasserIn |0 (DE-588)1161103937 |0 (DE-627)1024490858 |0 (DE-576)506356973 |4 aut | |
| 700 | 1 | |a Innmann, Moritz Maximilian |d 1985- |e VerfasserIn |0 (DE-588)1066499470 |0 (DE-627)817645535 |0 (DE-576)426014391 |4 aut | |
| 700 | 1 | |a Renkawitz, Tobias |d 1976- |e VerfasserIn |0 (DE-588)129303615 |0 (DE-627)392614979 |0 (DE-576)297588028 |4 aut | |
| 700 | 1 | |a Walker, Tilman |d 1985- |e VerfasserIn |0 (DE-588)1036568962 |0 (DE-627)750561149 |0 (DE-576)384812252 |4 aut | |
| 700 | 1 | |a Reiner, Tobias |d 1982- |e VerfasserIn |0 (DE-588)1038723787 |0 (DE-627)766370356 |0 (DE-576)392759853 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t The journal of arthroplasty |d Orlando, Fla. : Churchill Livingstone, 1986 |g 40(2025), 2, Seite 467-474 |h Online-Ressource |w (DE-627)326645411 |w (DE-600)2041553-9 |w (DE-576)104194421 |x 1532-8406 |7 nnas |a Elevated blood tantalum concentrations in patients following reconstruction of severe acetabular defects in total hip arthroplasty using modular tantalum augments in combination with uncemented tantalum cups |
| 773 | 1 | 8 | |g volume:40 |g year:2025 |g number:2 |g pages:467-474 |g extent:8 |a Elevated blood tantalum concentrations in patients following reconstruction of severe acetabular defects in total hip arthroplasty using modular tantalum augments in combination with uncemented tantalum cups |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.arth.2024.05.068 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S0883540324005400 |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20250723 | ||
| 993 | |a Article | ||
| 994 | |a 2024 | ||
| 998 | |g 1038723787 |a Reiner, Tobias |m 1038723787:Reiner, Tobias |d 910000 |d 911460 |d 50000 |e 910000PR1038723787 |e 911460PR1038723787 |e 50000PR1038723787 |k 0/910000/ |k 1/910000/911460/ |k 0/50000/ |p 8 |y j | ||
| 998 | |g 1036568962 |a Walker, Tilman |m 1036568962:Walker, Tilman |d 910000 |d 911460 |d 50000 |e 910000PW1036568962 |e 911460PW1036568962 |e 50000PW1036568962 |k 0/910000/ |k 1/910000/911460/ |k 0/50000/ |p 7 | ||
| 998 | |g 129303615 |a Renkawitz, Tobias |m 129303615:Renkawitz, Tobias |d 910000 |d 911460 |e 910000PR129303615 |e 911460PR129303615 |k 0/910000/ |k 1/910000/911460/ |p 6 | ||
| 998 | |g 1066499470 |a Innmann, Moritz Maximilian |m 1066499470:Innmann, Moritz Maximilian |d 910000 |d 911460 |e 910000PI1066499470 |e 911460PI1066499470 |k 0/910000/ |k 1/910000/911460/ |p 5 | ||
| 998 | |g 1161103937 |a Hetto, Pit |m 1161103937:Hetto, Pit |d 910000 |d 911460 |e 910000PH1161103937 |e 911460PH1161103937 |k 0/910000/ |k 1/910000/911460/ |p 4 | ||
| 998 | |g 126160217X |a Trefzer, Raphael |m 126160217X:Trefzer, Raphael |d 910000 |d 911460 |e 910000PT126160217X |e 911460PT126160217X |k 0/910000/ |k 1/910000/911460/ |p 3 | ||
| 998 | |g 1373842113 |a Müller, Lisa-Marie |m 1373842113:Müller, Lisa-Marie |d 50000 |e 50000PM1373842113 |k 0/50000/ |p 2 | ||
| 998 | |g 1045003727 |a Spranz, David Maximilian |m 1045003727:Spranz, David Maximilian |d 910000 |d 911460 |e 910000PS1045003727 |e 911460PS1045003727 |k 0/910000/ |k 1/910000/911460/ |p 1 |x j | ||
| 999 | |a KXP-PPN1931625743 |e 4749167630 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"language":["eng"],"title":[{"title":"Elevated blood tantalum concentrations in patients following reconstruction of severe acetabular defects in total hip arthroplasty using modular tantalum augments in combination with uncemented tantalum cups","title_sort":"Elevated blood tantalum concentrations in patients following reconstruction of severe acetabular defects in total hip arthroplasty using modular tantalum augments in combination with uncemented tantalum cups"}],"person":[{"display":"Spranz, David Maximilian","given":"David Maximilian","family":"Spranz","role":"aut"},{"given":"Lisa-Marie","display":"Müller, Lisa-Marie","family":"Müller","role":"aut"},{"family":"Trefzer","display":"Trefzer, Raphael","given":"Raphael","role":"aut"},{"given":"Pit","display":"Hetto, Pit","family":"Hetto","role":"aut"},{"family":"Innmann","display":"Innmann, Moritz Maximilian","given":"Moritz Maximilian","role":"aut"},{"family":"Renkawitz","given":"Tobias","display":"Renkawitz, Tobias","role":"aut"},{"role":"aut","family":"Walker","display":"Walker, Tilman","given":"Tilman"},{"family":"Reiner","display":"Reiner, Tobias","given":"Tobias","role":"aut"}],"recId":"1931625743","name":{"displayForm":["David Spranz, Lisa-Marie Müller, Raphael Trefzer, Pit Hetto, Moritz Innmann, Tobias Renkawitz, Tilman Walker, Tobias Reiner"]},"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"31 May 2024"}],"relHost":[{"pubHistory":["1.1986 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Elevated blood tantalum concentrations in patients following reconstruction of severe acetabular defects in total hip arthroplasty using modular tantalum augments in combination with uncemented tantalum cupsThe journal of arthroplasty","recId":"326645411","language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["326645411"],"zdb":["2041553-9"],"issn":["1532-8406"]},"part":{"extent":"8","issue":"2","volume":"40","text":"40(2025), 2, Seite 467-474","year":"2025","pages":"467-474"},"note":["Gesehen am 17.01.11"],"origin":[{"publisher":"Churchill Livingstone","dateIssuedDisp":"1986-","dateIssuedKey":"1986","publisherPlace":"Orlando, Fla."}],"title":[{"title":"The journal of arthroplasty","subtitle":"official journal of the American Association of Hip and Knee Surgeons","title_sort":"journal of arthroplasty"}]}],"note":["Gesehen am 23.07.2025"],"physDesc":[{"extent":"8 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"eki":["1931625743"],"doi":["10.1016/j.arth.2024.05.068"]}} | ||
| SRT | |a SPRANZDAVIELEVATEDBL3120 | ||