A new retest-stable tortuosity metric for retinal vessel analyses

Existing retinal vessel tortuosity metrics lack standardization and retest reliability, hindering their clinical utility. Our study addresses this gap by introducing a novel metric, coined as the “vascular curvature index” (VCI), to enhance accuracy and consistency in biomarkers associated with medi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Giesser, Samuel David (VerfasserIn) , Turgut, Ferhat (VerfasserIn) , Saad, Amr (VerfasserIn) , Sommer, Chiara (VerfasserIn) , Zhou, Yukun (VerfasserIn) , Wagner, Siegfried Karl (VerfasserIn) , Keane, Pearse Andrew (VerfasserIn) , Becker, Matthias D. (VerfasserIn) , Cabrera DeBuc, Delia (VerfasserIn) , Somfai, Gábor Márk (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: October 2024
In: Investigative ophthalmology & visual science
Year: 2024, Jahrgang: 65, Heft: 12, Pages: 1-7
ISSN:1552-5783
DOI:10.1167/iovs.65.12.30
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1167/iovs.65.12.30
Volltext
Verfasserangaben:Samuel David Giesser, Ferhat Turgut, Amr Saad, Chiara Sommer, Yukun Zhou, Siegfried Karl Wagner, Pearse Andrew Keane, Matthias Becker, Delia Cabrera DeBuc, and Gábor Márk Somfai

MARC

LEADER 00000naa a2200000 c 4500
001 1933089776
003 DE-627
005 20250813082707.0
007 cr uuu---uuuuu
008 250813s2024 xx |||||o 00| ||eng c
024 7 |a 10.1167/iovs.65.12.30  |2 doi 
035 |a (DE-627)1933089776 
035 |a (DE-599)KXP1933089776 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Giesser, Samuel David  |e VerfasserIn  |0 (DE-588)1373716681  |0 (DE-627)1933090294  |4 aut 
245 1 2 |a A new retest-stable tortuosity metric for retinal vessel analyses  |c Samuel David Giesser, Ferhat Turgut, Amr Saad, Chiara Sommer, Yukun Zhou, Siegfried Karl Wagner, Pearse Andrew Keane, Matthias Becker, Delia Cabrera DeBuc, and Gábor Márk Somfai 
264 1 |c October 2024 
300 |b Diagramme 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 13.08.2025 
520 |a Existing retinal vessel tortuosity metrics lack standardization and retest reliability, hindering their clinical utility. Our study addresses this gap by introducing a novel metric, coined as the “vascular curvature index” (VCI), to enhance accuracy and consistency in biomarkers associated with medical conditions. We assess VCI's performance in terms of retest reliability in healthy subjects to transform early detection and monitoring approaches for various diseases. We recruited 44 patients for a single-session study, capturing fundus images before and after a five-minute break. Using AutoMorph, we generated vessel segmentation maps and evaluated retest reliability using multiple tortuosity metrics. The VCI was introduced and statistically compared to existing metrics. We performed a paired one-sided t-test to test for significantly improved retest reliability of our newly proposed metric. We analyzed distribution histograms, Fisher-Pearson coefficient of skewness, and correlation matrices for further insights. VCI is the most retest-reliable metric, statistically surpassing other curvature metrics, except inverse spherical radius tortuosity. With a somewhat negatively distributed pattern (coefficient of skewness of −0.52), VCI exhibits the strongest correlation with the second most retest-reliable metric; inverse-radius-tortuosity (Pearson and Spearman correlation of 0.7 and 0.72, respectively). Its correlation with angle-tortuosity is lower (Pearson and Spearman correlation of 0.05 and 0.07, respectively). The VCI emerges as a highly retest-reliable metric with a relatively normal distribution in healthy patients. Further investigation is warranted to evaluate its clinical performance in real-world applications, potentially influencing proactive healthcare interventions and personalized treatment decision-making. 
700 1 |a Turgut, Ferhat  |e VerfasserIn  |4 aut 
700 1 |a Saad, Amr  |e VerfasserIn  |4 aut 
700 1 |a Sommer, Chiara  |e VerfasserIn  |4 aut 
700 1 |a Zhou, Yukun  |e VerfasserIn  |4 aut 
700 1 |a Wagner, Siegfried Karl  |e VerfasserIn  |4 aut 
700 1 |a Keane, Pearse Andrew  |e VerfasserIn  |4 aut 
700 1 |a Becker, Matthias D.  |e VerfasserIn  |0 (DE-588)135571855  |0 (DE-627)56707255X  |0 (DE-576)300521871  |4 aut 
700 1 |a Cabrera DeBuc, Delia  |e VerfasserIn  |4 aut 
700 1 |a Somfai, Gábor Márk  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Investigative ophthalmology & visual science  |d Rockville, Md. : ARVO, 1977  |g 65(2024), 12 vom: Okt., Artikel-ID 30, Seite 1-7  |h Online-Ressource  |w (DE-627)32048159X  |w (DE-600)2009858-3  |w (DE-576)091138515  |x 1552-5783  |7 nnas  |a A new retest-stable tortuosity metric for retinal vessel analyses 
773 1 8 |g volume:65  |g year:2024  |g number:12  |g month:10  |g elocationid:30  |g pages:1-7  |g extent:7  |a A new retest-stable tortuosity metric for retinal vessel analyses 
856 4 0 |u https://doi.org/10.1167/iovs.65.12.30  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20250813 
993 |a Article 
994 |a 2024 
998 |g 135571855  |a Becker, Matthias D.  |m 135571855:Becker, Matthias D.  |d 50000  |e 50000PB135571855  |k 0/50000/  |p 8 
999 |a KXP-PPN1933089776  |e 4756881599 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.1167/iovs.65.12.30"],"eki":["1933089776"]},"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"October 2024"}],"name":{"displayForm":["Samuel David Giesser, Ferhat Turgut, Amr Saad, Chiara Sommer, Yukun Zhou, Siegfried Karl Wagner, Pearse Andrew Keane, Matthias Becker, Delia Cabrera DeBuc, and Gábor Márk Somfai"]},"recId":"1933089776","person":[{"family":"Giesser","role":"aut","given":"Samuel David","display":"Giesser, Samuel David"},{"display":"Turgut, Ferhat","given":"Ferhat","role":"aut","family":"Turgut"},{"given":"Amr","role":"aut","family":"Saad","display":"Saad, Amr"},{"display":"Sommer, Chiara","family":"Sommer","given":"Chiara","role":"aut"},{"display":"Zhou, Yukun","role":"aut","given":"Yukun","family":"Zhou"},{"given":"Siegfried Karl","role":"aut","family":"Wagner","display":"Wagner, Siegfried Karl"},{"display":"Keane, Pearse Andrew","given":"Pearse Andrew","role":"aut","family":"Keane"},{"role":"aut","given":"Matthias D.","family":"Becker","display":"Becker, Matthias D."},{"family":"Cabrera DeBuc","role":"aut","given":"Delia","display":"Cabrera DeBuc, Delia"},{"family":"Somfai","role":"aut","given":"Gábor Márk","display":"Somfai, Gábor Márk"}],"title":[{"title_sort":"new retest-stable tortuosity metric for retinal vessel analyses","title":"A new retest-stable tortuosity metric for retinal vessel analyses"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"physDesc":[{"noteIll":"Diagramme","extent":"7 S."}],"language":["eng"],"relHost":[{"part":{"volume":"65","pages":"1-7","text":"65(2024), 12 vom: Okt., Artikel-ID 30, Seite 1-7","extent":"7","issue":"12","year":"2024"},"pubHistory":["16.1977 -"],"note":["Gesehen am 01.08.2016"],"titleAlt":[{"title":"IOVS"}],"disp":"A new retest-stable tortuosity metric for retinal vessel analysesInvestigative ophthalmology & visual science","recId":"32048159X","id":{"zdb":["2009858-3"],"issn":["1552-5783"],"eki":["32048159X"]},"origin":[{"dateIssuedKey":"1977","publisher":"ARVO ; [Verlag nicht ermittelbar]","dateIssuedDisp":"1977-","publisherPlace":"Rockville, Md. ; St. Louis, Mo."}],"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"corporate":[{"role":"isb","display":"Association for Research in Vision and Ophthalmology"}],"title":[{"title_sort":"Investigative ophthalmology & visual science","title":"Investigative ophthalmology & visual science","subtitle":"IOVS ; official journal of the Association for Research in Vision and Ophthalmology"}]}],"note":["Gesehen am 13.08.2025"]} 
SRT |a GIESSERSAMNEWRETESTS2024