Rapid and reversible adaptation of a clinical linear accelerator for electron FLASH radiotherapy
Purpose - The aim of this work was to establish a procedure that allows the conversion of a standard clinical LINAC into a “FLASH” LINAC capable of delivering ultra-high dose rates above 40 Gy/s, with minimal, fully reversible modifications to the device. A dosimetric characterization of the resulti...
Saved in:
| Main Authors: | , , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
August 2025
|
| In: |
Physica medica
Year: 2025, Volume: 136, Pages: 1-8 |
| ISSN: | 1724-191X |
| DOI: | 10.1016/j.ejmp.2025.105032 |
| Online Access: | Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.ejmp.2025.105032 Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S1120179725001425 |
| Author Notes: | Frank Schneider, Cornelius J. Bauer, Ida D. Göbel, Clarence King, Maria Francesca Spadea, Joao Seco, Frank A. Giordano, Jens Fleckenstein |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1933653760 | ||
| 003 | DE-627 | ||
| 005 | 20250913141901.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 250821s2025 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.ejmp.2025.105032 |2 doi | |
| 035 | |a (DE-627)1933653760 | ||
| 035 | |a (DE-599)KXP1933653760 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Schneider, Frank |d 1980- |e VerfasserIn |0 (DE-588)14139093X |0 (DE-627)627292321 |0 (DE-576)323515576 |4 aut | |
| 245 | 1 | 0 | |a Rapid and reversible adaptation of a clinical linear accelerator for electron FLASH radiotherapy |c Frank Schneider, Cornelius J. Bauer, Ida D. Göbel, Clarence King, Maria Francesca Spadea, Joao Seco, Frank A. Giordano, Jens Fleckenstein |
| 264 | 1 | |c August 2025 | |
| 300 | |b Diagramme | ||
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Online verfügbar: 23. Juni 2025, Artikelversion: 23. Juni 2025 | ||
| 500 | |a Gesehen am 21.08.2025 | ||
| 520 | |a Purpose - The aim of this work was to establish a procedure that allows the conversion of a standard clinical LINAC into a “FLASH” LINAC capable of delivering ultra-high dose rates above 40 Gy/s, with minimal, fully reversible modifications to the device. A dosimetric characterization of the resulting treatment beam is presented. - Methods - A LINAC was modified to emit a 10 MeV electron FLASH beam. Modifications included the integration of a pulse control unit which consisted out of a scintillation detector and a transistor circuit. Beam parameters were optimized to maximize dose output. Beam characterization measurements were performed with different detectors in water: ionization chamber, diamond detector, radiographic films and scintillation detector. The resulting doses per pulse (DPP) and dose rates at different source-surface-distances (SSD) as well as the output reproducibility were determined. The beam was characterized with depth dose curves and lateral profiles. - Results - Conversion of a LINAC to FLASH mode was feasible in less than 30 min. Output was between DPPSSD=56cm = 1.69 ± 0.02 Gy and DPPSSD=100cm = 0.53 ± 0.01 Gy or dose rates between 676 ± 8 Gy/s and 213 ± 4 Gy/s. Reproducibility of DPP was better than 0.8 %. FLASH depth dose curves showed a higher range (R80 = 39.8 mm vs. 34.6 mm) and lateral beam profiles had a reduced flatness (from 5.5 % to 12.7 %) at SSD = 56 cm. - Conclusion - We present a fully reversible conversion method requiring minimal modifications to a LINAC to produce electron FLASH beams. The achieved DPP and mean dose rates demonstrated high reproducibility, meeting criteria for FLASH applications, and markedly simplifying access to this technology for broader implementation. | ||
| 650 | 4 | |a Dosimetry | |
| 650 | 4 | |a Electron beam | |
| 650 | 4 | |a FLASH | |
| 650 | 4 | |a LINAC | |
| 650 | 4 | |a Ultra-high dose rate | |
| 700 | 1 | |a Bauer, Cornelius Jonathan |d 1992- |e VerfasserIn |0 (DE-588)1289551057 |0 (DE-627)1845544358 |4 aut | |
| 700 | 1 | |a Göbel, Ida Dorothea |d 1999- |e VerfasserIn |0 (DE-588)1374405132 |0 (DE-627)1933654007 |4 aut | |
| 700 | 1 | |a King, Clarence |e VerfasserIn |4 aut | |
| 700 | 1 | |a Spadea, Maria Francesca |e VerfasserIn |4 aut | |
| 700 | 1 | |a Seco, Joao |e VerfasserIn |0 (DE-588)1120955866 |0 (DE-627)874146615 |0 (DE-576)480627010 |4 aut | |
| 700 | 1 | |a Giordano, Frank Anton |d 1980- |e VerfasserIn |0 (DE-588)136378455 |0 (DE-627)694333093 |0 (DE-576)300990529 |4 aut | |
| 700 | 1 | |a Fleckenstein, Jens |d 1981- |e VerfasserIn |0 (DE-588)102911918X |0 (DE-627)732477212 |0 (DE-576)376584599 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Physica medica |d Amsterdam : Elsevier, 1996 |g 136(2025) vom: Aug., Artikel-ID 105032, Seite 1-8 |h Online-Ressource |w (DE-627)364471417 |w (DE-600)2110535-2 |w (DE-576)272350176 |x 1724-191X |7 nnas |a Rapid and reversible adaptation of a clinical linear accelerator for electron FLASH radiotherapy |
| 773 | 1 | 8 | |g volume:136 |g year:2025 |g month:08 |g elocationid:105032 |g pages:1-8 |g extent:8 |a Rapid and reversible adaptation of a clinical linear accelerator for electron FLASH radiotherapy |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.ejmp.2025.105032 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S1120179725001425 |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20250821 | ||
| 993 | |a Article | ||
| 994 | |a 2025 | ||
| 998 | |g 102911918X |a Fleckenstein, Jens |m 102911918X:Fleckenstein, Jens |d 60000 |e 60000PF102911918X |k 0/60000/ |p 8 |y j | ||
| 998 | |g 136378455 |a Giordano, Frank Anton |m 136378455:Giordano, Frank Anton |d 60000 |d 63000 |e 60000PG136378455 |e 63000PG136378455 |k 0/60000/ |k 1/60000/63000/ |p 7 | ||
| 998 | |g 1374405132 |a Göbel, Ida |m 1374405132:Göbel, Ida |d 60000 |e 60000PG1374405132 |k 0/60000/ |p 3 | ||
| 998 | |g 1120955866 |a Seco, Joao |m 1120955866:Seco, Joao |d 130000 |e 130000PS1120955866 |k 0/130000/ |p 6 | ||
| 998 | |g 1289551057 |a Bauer, Cornelius Jonathan |m 1289551057:Bauer, Cornelius Jonathan |p 2 | ||
| 998 | |g 14139093X |a Schneider, Frank |m 14139093X:Schneider, Frank |d 60000 |e 60000PS14139093X |k 0/60000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1933653760 |e 4759352945 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"id":{"eki":["1933653760"],"doi":["10.1016/j.ejmp.2025.105032"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"physDesc":[{"extent":"8 S.","noteIll":"Diagramme"}],"relHost":[{"id":{"issn":["1724-191X"],"eki":["364471417"],"zdb":["2110535-2"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"subtitle":"European journal of medical physics ; an international journal devoted to the applications of physics to medicine and biology","title_sort":"Physica medica","title":"Physica medica"}],"physDesc":[{"extent":"Online-Ressource"}],"pubHistory":["Nachgewiesen 12.1996 -"],"disp":"Rapid and reversible adaptation of a clinical linear accelerator for electron FLASH radiotherapyPhysica medica","note":["Fortsetzung der Druck-Ausgabe","Gesehen am 12.11.2021"],"part":{"pages":"1-8","extent":"8","text":"136(2025) vom: Aug., Artikel-ID 105032, Seite 1-8","volume":"136","year":"2025"},"language":["eng"],"recId":"364471417","origin":[{"publisherPlace":"Amsterdam ; Pisa","dateIssuedDisp":"1996-","publisher":"Elsevier ; Istituti Editoriali e Poligrafici Internazionali","dateIssuedKey":"1996"}]}],"title":[{"title":"Rapid and reversible adaptation of a clinical linear accelerator for electron FLASH radiotherapy","title_sort":"Rapid and reversible adaptation of a clinical linear accelerator for electron FLASH radiotherapy"}],"person":[{"family":"Schneider","display":"Schneider, Frank","role":"aut","given":"Frank"},{"family":"Bauer","display":"Bauer, Cornelius Jonathan","role":"aut","given":"Cornelius Jonathan"},{"role":"aut","given":"Ida Dorothea","family":"Göbel","display":"Göbel, Ida Dorothea"},{"family":"King","display":"King, Clarence","role":"aut","given":"Clarence"},{"family":"Spadea","display":"Spadea, Maria Francesca","role":"aut","given":"Maria Francesca"},{"family":"Seco","display":"Seco, Joao","role":"aut","given":"Joao"},{"given":"Frank Anton","role":"aut","display":"Giordano, Frank Anton","family":"Giordano"},{"role":"aut","given":"Jens","family":"Fleckenstein","display":"Fleckenstein, Jens"}],"name":{"displayForm":["Frank Schneider, Cornelius J. Bauer, Ida D. Göbel, Clarence King, Maria Francesca Spadea, Joao Seco, Frank A. Giordano, Jens Fleckenstein"]},"recId":"1933653760","language":["eng"],"note":["Online verfügbar: 23. Juni 2025, Artikelversion: 23. Juni 2025","Gesehen am 21.08.2025"],"origin":[{"dateIssuedKey":"2025","dateIssuedDisp":"August 2025"}]} | ||
| SRT | |a SCHNEIDERFRAPIDANDRE2025 | ||