Rapid and reversible adaptation of a clinical linear accelerator for electron FLASH radiotherapy

Purpose - The aim of this work was to establish a procedure that allows the conversion of a standard clinical LINAC into a “FLASH” LINAC capable of delivering ultra-high dose rates above 40 Gy/s, with minimal, fully reversible modifications to the device. A dosimetric characterization of the resulti...

Full description

Saved in:
Bibliographic Details
Main Authors: Schneider, Frank (Author) , Bauer, Cornelius Jonathan (Author) , Göbel, Ida Dorothea (Author) , King, Clarence (Author) , Spadea, Maria Francesca (Author) , Seco, Joao (Author) , Giordano, Frank Anton (Author) , Fleckenstein, Jens (Author)
Format: Article (Journal)
Language:English
Published: August 2025
In: Physica medica
Year: 2025, Volume: 136, Pages: 1-8
ISSN:1724-191X
DOI:10.1016/j.ejmp.2025.105032
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.ejmp.2025.105032
Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S1120179725001425
Get full text
Author Notes:Frank Schneider, Cornelius J. Bauer, Ida D. Göbel, Clarence King, Maria Francesca Spadea, Joao Seco, Frank A. Giordano, Jens Fleckenstein

MARC

LEADER 00000caa a2200000 c 4500
001 1933653760
003 DE-627
005 20250913141901.0
007 cr uuu---uuuuu
008 250821s2025 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejmp.2025.105032  |2 doi 
035 |a (DE-627)1933653760 
035 |a (DE-599)KXP1933653760 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schneider, Frank  |d 1980-  |e VerfasserIn  |0 (DE-588)14139093X  |0 (DE-627)627292321  |0 (DE-576)323515576  |4 aut 
245 1 0 |a Rapid and reversible adaptation of a clinical linear accelerator for electron FLASH radiotherapy  |c Frank Schneider, Cornelius J. Bauer, Ida D. Göbel, Clarence King, Maria Francesca Spadea, Joao Seco, Frank A. Giordano, Jens Fleckenstein 
264 1 |c August 2025 
300 |b Diagramme 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online verfügbar: 23. Juni 2025, Artikelversion: 23. Juni 2025 
500 |a Gesehen am 21.08.2025 
520 |a Purpose - The aim of this work was to establish a procedure that allows the conversion of a standard clinical LINAC into a “FLASH” LINAC capable of delivering ultra-high dose rates above 40 Gy/s, with minimal, fully reversible modifications to the device. A dosimetric characterization of the resulting treatment beam is presented. - Methods - A LINAC was modified to emit a 10 MeV electron FLASH beam. Modifications included the integration of a pulse control unit which consisted out of a scintillation detector and a transistor circuit. Beam parameters were optimized to maximize dose output. Beam characterization measurements were performed with different detectors in water: ionization chamber, diamond detector, radiographic films and scintillation detector. The resulting doses per pulse (DPP) and dose rates at different source-surface-distances (SSD) as well as the output reproducibility were determined. The beam was characterized with depth dose curves and lateral profiles. - Results - Conversion of a LINAC to FLASH mode was feasible in less than 30 min. Output was between DPPSSD=56cm = 1.69 ± 0.02 Gy and DPPSSD=100cm = 0.53 ± 0.01 Gy or dose rates between 676 ± 8 Gy/s and 213 ± 4 Gy/s. Reproducibility of DPP was better than 0.8 %. FLASH depth dose curves showed a higher range (R80 = 39.8 mm vs. 34.6 mm) and lateral beam profiles had a reduced flatness (from 5.5 % to 12.7 %) at SSD = 56 cm. - Conclusion - We present a fully reversible conversion method requiring minimal modifications to a LINAC to produce electron FLASH beams. The achieved DPP and mean dose rates demonstrated high reproducibility, meeting criteria for FLASH applications, and markedly simplifying access to this technology for broader implementation. 
650 4 |a Dosimetry 
650 4 |a Electron beam 
650 4 |a FLASH 
650 4 |a LINAC 
650 4 |a Ultra-high dose rate 
700 1 |a Bauer, Cornelius Jonathan  |d 1992-  |e VerfasserIn  |0 (DE-588)1289551057  |0 (DE-627)1845544358  |4 aut 
700 1 |a Göbel, Ida Dorothea  |d 1999-  |e VerfasserIn  |0 (DE-588)1374405132  |0 (DE-627)1933654007  |4 aut 
700 1 |a King, Clarence  |e VerfasserIn  |4 aut 
700 1 |a Spadea, Maria Francesca  |e VerfasserIn  |4 aut 
700 1 |a Seco, Joao  |e VerfasserIn  |0 (DE-588)1120955866  |0 (DE-627)874146615  |0 (DE-576)480627010  |4 aut 
700 1 |a Giordano, Frank Anton  |d 1980-  |e VerfasserIn  |0 (DE-588)136378455  |0 (DE-627)694333093  |0 (DE-576)300990529  |4 aut 
700 1 |a Fleckenstein, Jens  |d 1981-  |e VerfasserIn  |0 (DE-588)102911918X  |0 (DE-627)732477212  |0 (DE-576)376584599  |4 aut 
773 0 8 |i Enthalten in  |t Physica medica  |d Amsterdam : Elsevier, 1996  |g 136(2025) vom: Aug., Artikel-ID 105032, Seite 1-8  |h Online-Ressource  |w (DE-627)364471417  |w (DE-600)2110535-2  |w (DE-576)272350176  |x 1724-191X  |7 nnas  |a Rapid and reversible adaptation of a clinical linear accelerator for electron FLASH radiotherapy 
773 1 8 |g volume:136  |g year:2025  |g month:08  |g elocationid:105032  |g pages:1-8  |g extent:8  |a Rapid and reversible adaptation of a clinical linear accelerator for electron FLASH radiotherapy 
856 4 0 |u https://doi.org/10.1016/j.ejmp.2025.105032  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1120179725001425  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20250821 
993 |a Article 
994 |a 2025 
998 |g 102911918X  |a Fleckenstein, Jens  |m 102911918X:Fleckenstein, Jens  |d 60000  |e 60000PF102911918X  |k 0/60000/  |p 8  |y j 
998 |g 136378455  |a Giordano, Frank Anton  |m 136378455:Giordano, Frank Anton  |d 60000  |d 63000  |e 60000PG136378455  |e 63000PG136378455  |k 0/60000/  |k 1/60000/63000/  |p 7 
998 |g 1374405132  |a Göbel, Ida  |m 1374405132:Göbel, Ida  |d 60000  |e 60000PG1374405132  |k 0/60000/  |p 3 
998 |g 1120955866  |a Seco, Joao  |m 1120955866:Seco, Joao  |d 130000  |e 130000PS1120955866  |k 0/130000/  |p 6 
998 |g 1289551057  |a Bauer, Cornelius Jonathan  |m 1289551057:Bauer, Cornelius Jonathan  |p 2 
998 |g 14139093X  |a Schneider, Frank  |m 14139093X:Schneider, Frank  |d 60000  |e 60000PS14139093X  |k 0/60000/  |p 1  |x j 
999 |a KXP-PPN1933653760  |e 4759352945 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1933653760"],"doi":["10.1016/j.ejmp.2025.105032"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"physDesc":[{"extent":"8 S.","noteIll":"Diagramme"}],"relHost":[{"id":{"issn":["1724-191X"],"eki":["364471417"],"zdb":["2110535-2"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"subtitle":"European journal of medical physics ; an international journal devoted to the applications of physics to medicine and biology","title_sort":"Physica medica","title":"Physica medica"}],"physDesc":[{"extent":"Online-Ressource"}],"pubHistory":["Nachgewiesen 12.1996 -"],"disp":"Rapid and reversible adaptation of a clinical linear accelerator for electron FLASH radiotherapyPhysica medica","note":["Fortsetzung der Druck-Ausgabe","Gesehen am 12.11.2021"],"part":{"pages":"1-8","extent":"8","text":"136(2025) vom: Aug., Artikel-ID 105032, Seite 1-8","volume":"136","year":"2025"},"language":["eng"],"recId":"364471417","origin":[{"publisherPlace":"Amsterdam ; Pisa","dateIssuedDisp":"1996-","publisher":"Elsevier ; Istituti Editoriali e Poligrafici Internazionali","dateIssuedKey":"1996"}]}],"title":[{"title":"Rapid and reversible adaptation of a clinical linear accelerator for electron FLASH radiotherapy","title_sort":"Rapid and reversible adaptation of a clinical linear accelerator for electron FLASH radiotherapy"}],"person":[{"family":"Schneider","display":"Schneider, Frank","role":"aut","given":"Frank"},{"family":"Bauer","display":"Bauer, Cornelius Jonathan","role":"aut","given":"Cornelius Jonathan"},{"role":"aut","given":"Ida Dorothea","family":"Göbel","display":"Göbel, Ida Dorothea"},{"family":"King","display":"King, Clarence","role":"aut","given":"Clarence"},{"family":"Spadea","display":"Spadea, Maria Francesca","role":"aut","given":"Maria Francesca"},{"family":"Seco","display":"Seco, Joao","role":"aut","given":"Joao"},{"given":"Frank Anton","role":"aut","display":"Giordano, Frank Anton","family":"Giordano"},{"role":"aut","given":"Jens","family":"Fleckenstein","display":"Fleckenstein, Jens"}],"name":{"displayForm":["Frank Schneider, Cornelius J. Bauer, Ida D. Göbel, Clarence King, Maria Francesca Spadea, Joao Seco, Frank A. Giordano, Jens Fleckenstein"]},"recId":"1933653760","language":["eng"],"note":["Online verfügbar: 23. Juni 2025, Artikelversion: 23. Juni 2025","Gesehen am 21.08.2025"],"origin":[{"dateIssuedKey":"2025","dateIssuedDisp":"August 2025"}]} 
SRT |a SCHNEIDERFRAPIDANDRE2025