Gait examination in catatonia using 3D optical markerless motion tracking

Background - Three-dimensional (3D) markerless motion capture (MoCap) systems are emerging as powerful tools for the objective assessment of sensori-/psychomotor abnormalities in mental disorders. However, the application of 3D-MoCap technology for gait analysis in catatonia remains unexplored. - Me...

Full description

Saved in:
Bibliographic Details
Main Authors: Akkoc Altinok, Dilsa Cemre (Author) , Volkmer, Sebastian (Author) , Ohl, Kristin (Author) , Brandt, Geva A. (Author) , Daub, Jonas (Author) , Fritze, Stefan (Author) , Peretzke, Robin (Author) , Neher, Peter (Author) , Northoff, Georg (Author) , Meyer-Lindenberg, Andreas (Author) , Hirjak, Dusan (Author)
Format: Article (Journal)
Language:English
Published: July 2025
In: Schizophrenia research
Year: 2025, Volume: 281, Pages: 249-259
ISSN:1573-2509
DOI:10.1016/j.schres.2025.05.022
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.schres.2025.05.022
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0920996425001963
Get full text
Author Notes:Dilsa Cemre Akkoc Altinok, Sebastian Volkmer, Kristin Ohl, Geva A. Brandt, Jonas Daub, Stefan Fritze, Robin Peretzke, Peter F. Neher, Georg Northoff, Andreas Meyer-Lindenberg, Dusan Hirjak

MARC

LEADER 00000caa a2200000 c 4500
001 1934707902
003 DE-627
005 20250913141910.0
007 cr uuu---uuuuu
008 250826s2025 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.schres.2025.05.022  |2 doi 
035 |a (DE-627)1934707902 
035 |a (DE-599)KXP1934707902 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 11  |2 sdnb 
100 1 |a Akkoc Altinok, Dilsa Cemre  |d 1994-  |e VerfasserIn  |0 (DE-588)1278397124  |0 (DE-627)1831287218  |4 aut 
245 1 0 |a Gait examination in catatonia using 3D optical markerless motion tracking  |c Dilsa Cemre Akkoc Altinok, Sebastian Volkmer, Kristin Ohl, Geva A. Brandt, Jonas Daub, Stefan Fritze, Robin Peretzke, Peter F. Neher, Georg Northoff, Andreas Meyer-Lindenberg, Dusan Hirjak 
264 1 |c July 2025 
300 |b Illustrationen, Diagramme 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online verfügbar: 27. Mai 2025, Artikelversion: 27. Mai 2025 
500 |a Gesehen am 26.08.2025 
520 |a Background - Three-dimensional (3D) markerless motion capture (MoCap) systems are emerging as powerful tools for the objective assessment of sensori-/psychomotor abnormalities in mental disorders. However, the application of 3D-MoCap technology for gait analysis in catatonia remains unexplored. - Methods - This study included 23 patients with and 53 patients without catatonia, classified according to ICD-11. Catatonia severity was assessed using the Northoff Catatonia Rating Scale (NCRS) and the Bush-Francis Catatonia Rating Scale (BFCRS). Gait was examined via a 3D markerless MoCap system, Salpêtrière Retardation Rating Scale (SRRS), the Unified Parkinson's Disease Rating Scale (UPDRS), and the Heidelberg Neurological Soft Signs Scale (NSS). - Results - Principal component (PC) analysis of spatiotemporal gait parameters revealed four principal components, accounting for 51.98 % (PC1), 23.46 % (PC2), 7.98 % (PC3), and 6.3 % (PC4) of the total gait variance. PC1 was primarily characterized by time-dependent features such as cycle time and stance time, while PC2 predominantly captured space-dependent features, including stride length and stride width. PC1 was significantly reduced in the catatonia group (p < 0.05); however, it was not significantly associated with catatonia severity. Total scores and gait-related subitems of the SRRS and UPDRS scales differed significantly between the catatonia and non-catatonia groups (p < 0.05, corrected). - Conclusion - The results of this study demonstrates for the first time that 3D markerless MoCap can effectively quantify gait in catatonia, revealing alterations in temporal and spatial gait dynamics. Future research should explore the longitudinal effects of catatonia treatment on gait patterns and investigate potential biomarkers for disease monitoring. 
650 4 |a 3D markerless motion capturing 
650 4 |a Catatonia 
650 4 |a Clinical rating scales 
650 4 |a Gait analysis 
650 4 |a Movement tracking 
700 1 |a Volkmer, Sebastian  |e VerfasserIn  |0 (DE-588)1317351657  |0 (DE-627)187935246X  |4 aut 
700 1 |a Ohl, Kristin  |d 1997-  |e VerfasserIn  |0 (DE-588)1374788902  |0 (DE-627)1934708674  |4 aut 
700 1 |a Brandt, Geva A.  |d 1990-  |e VerfasserIn  |0 (DE-588)1307073557  |0 (DE-627)1867431513  |4 aut 
700 1 |a Daub, Jonas  |e VerfasserIn  |0 (DE-588)1286747910  |0 (DE-627)1843325608  |4 aut 
700 1 |a Fritze, Stefan  |d 1987-  |e VerfasserIn  |0 (DE-588)1162848642  |0 (DE-627)1027259030  |0 (DE-576)507615700  |4 aut 
700 1 |a Peretzke, Robin  |e VerfasserIn  |0 (DE-588)1323545689  |0 (DE-627)1883482127  |4 aut 
700 1 |a Neher, Peter  |d 1984-  |e VerfasserIn  |0 (DE-588)1052246052  |0 (DE-627)788077287  |0 (DE-576)408004746  |4 aut 
700 1 |a Northoff, Georg  |d 1963-  |e VerfasserIn  |0 (DE-588)115543929  |0 (DE-627)07731929X  |0 (DE-576)167004344  |4 aut 
700 1 |a Meyer-Lindenberg, Andreas  |d 1965-  |e VerfasserIn  |0 (DE-588)1029137390  |0 (DE-627)732483069  |0 (DE-576)376589876  |4 aut 
700 1 |a Hirjak, Dusan  |d 1985-  |e VerfasserIn  |0 (DE-588)1024129306  |0 (DE-627)719194717  |0 (DE-576)367982463  |4 aut 
773 0 8 |i Enthalten in  |t Schizophrenia research  |d Amsterdam [u.a.] : Elsevier Science, 1988  |g 281(2025) vom: Juli, Seite 249-259  |h Online-Ressource  |w (DE-627)306710307  |w (DE-600)1500726-1  |w (DE-576)082435820  |x 1573-2509  |7 nnas  |a Gait examination in catatonia using 3D optical markerless motion tracking 
773 1 8 |g volume:281  |g year:2025  |g month:07  |g pages:249-259  |g extent:11  |a Gait examination in catatonia using 3D optical markerless motion tracking 
856 4 0 |u https://doi.org/10.1016/j.schres.2025.05.022  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0920996425001963  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20250826 
993 |a Article 
994 |a 2025 
998 |g 1024129306  |a Hirjak, Dusan  |m 1024129306:Hirjak, Dusan  |d 60000  |e 60000PH1024129306  |k 0/60000/  |p 11 
998 |g 1029137390  |a Meyer-Lindenberg, Andreas  |m 1029137390:Meyer-Lindenberg, Andreas  |d 60000  |e 60000PM1029137390  |k 0/60000/  |p 10 
998 |g 1052246052  |a Neher, Peter  |m 1052246052:Neher, Peter  |d 910000  |d 911400  |e 910000PN1052246052  |e 911400PN1052246052  |k 0/910000/  |k 1/910000/911400/  |p 8 
998 |g 1323545689  |a Peretzke, Robin  |m 1323545689:Peretzke, Robin  |d 910000  |d 911400  |e 910000PP1323545689  |e 911400PP1323545689  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 1162848642  |a Fritze, Stefan  |m 1162848642:Fritze, Stefan  |d 60000  |e 60000PF1162848642  |k 0/60000/  |p 6 
998 |g 1286747910  |a Daub, Jonas  |m 1286747910:Daub, Jonas  |d 60000  |e 60000PD1286747910  |k 0/60000/  |p 5 
998 |g 1307073557  |a Brandt, Geva A.  |m 1307073557:Brandt, Geva A.  |d 60000  |e 60000PB1307073557  |k 0/60000/  |p 4 
998 |g 1374788902  |a Ohl, Kristin  |m 1374788902:Ohl, Kristin  |d 60000  |e 60000PO1374788902  |k 0/60000/  |p 3 
998 |g 1317351657  |a Volkmer, Sebastian  |m 1317351657:Volkmer, Sebastian  |d 60000  |e 60000PV1317351657  |k 0/60000/  |p 2 
999 |a KXP-PPN1934707902  |e 4764161613 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1934707902","physDesc":[{"extent":"11 S.","noteIll":"Illustrationen, Diagramme"}],"title":[{"title_sort":"Gait examination in catatonia using 3D optical markerless motion tracking","title":"Gait examination in catatonia using 3D optical markerless motion tracking"}],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Online verfügbar: 27. Mai 2025, Artikelversion: 27. Mai 2025","Gesehen am 26.08.2025"],"origin":[{"dateIssuedDisp":"July 2025","dateIssuedKey":"2025"}],"person":[{"family":"Akkoc Altinok","given":"Dilsa Cemre","role":"aut","display":"Akkoc Altinok, Dilsa Cemre"},{"role":"aut","given":"Sebastian","family":"Volkmer","display":"Volkmer, Sebastian"},{"display":"Ohl, Kristin","family":"Ohl","given":"Kristin","role":"aut"},{"display":"Brandt, Geva A.","given":"Geva A.","role":"aut","family":"Brandt"},{"display":"Daub, Jonas","role":"aut","given":"Jonas","family":"Daub"},{"display":"Fritze, Stefan","family":"Fritze","role":"aut","given":"Stefan"},{"role":"aut","given":"Robin","family":"Peretzke","display":"Peretzke, Robin"},{"role":"aut","given":"Peter","family":"Neher","display":"Neher, Peter"},{"display":"Northoff, Georg","given":"Georg","role":"aut","family":"Northoff"},{"display":"Meyer-Lindenberg, Andreas","family":"Meyer-Lindenberg","given":"Andreas","role":"aut"},{"family":"Hirjak","given":"Dusan","role":"aut","display":"Hirjak, Dusan"}],"relHost":[{"disp":"Gait examination in catatonia using 3D optical markerless motion trackingSchizophrenia research","physDesc":[{"extent":"Online-Ressource"}],"recId":"306710307","type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 09.12.04","Ungezählte Beil.: Supplement"],"id":{"issn":["1573-2509"],"eki":["306710307"],"zdb":["1500726-1"]},"part":{"volume":"281","text":"281(2025) vom: Juli, Seite 249-259","extent":"11","pages":"249-259","year":"2025"},"title":[{"title_sort":"Schizophrenia research","title":"Schizophrenia research","subtitle":"an international multidisciplinary journal"}],"origin":[{"publisher":"Elsevier Science","publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1988","dateIssuedDisp":"1988-"}],"pubHistory":["1.1988 -"]}],"id":{"doi":["10.1016/j.schres.2025.05.022"],"eki":["1934707902"]},"name":{"displayForm":["Dilsa Cemre Akkoc Altinok, Sebastian Volkmer, Kristin Ohl, Geva A. Brandt, Jonas Daub, Stefan Fritze, Robin Peretzke, Peter F. Neher, Georg Northoff, Andreas Meyer-Lindenberg, Dusan Hirjak"]}} 
SRT |a AKKOCALTINGAITEXAMIN2025