Analysis of screw/pedicle-width ratio and accuracy in navigated versus 3D-controlled fluoroscopy-guided pedicle screw placement

Study Design - Retrospective cohort study. - Objectives - Due to the close anatomic relationship between the pedicle and neurovascular structures, avoiding pedicle perforations is crucial in pedicle screw placement. Still, the use of larger screws has biomechanical advantages. Intraoperative 2D and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Gierse, Jula (VerfasserIn) , Zimmermann, Felix (VerfasserIn) , Grützner, Paul Alfred (VerfasserIn) , Stallkamp, Jan (VerfasserIn) , Vetter, Sven Y. (VerfasserIn) , Mandelka, Leon Eric (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: May 19, 2025
In: Global spine journal
Year: 2025, Heft: OnlineFirst, Pages: 1-9
ISSN:2192-5690
DOI:10.1177/21925682251343523
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1177/21925682251343523
Verlag, kostenfrei, Volltext: https://journals.sagepub.com/doi/10.1177/21925682251343523
Volltext
Verfasserangaben:Jula Gierse MD, Felix Zimmermann MD, Paul A. Grützner, Jan Stallkamp, Sven Y. Vetter, and Eric Mandelka

MARC

LEADER 00000caa a22000002c 4500
001 1935081136
003 DE-627
005 20250902111843.0
007 cr uuu---uuuuu
008 250901s2025 xx |||||o 00| ||eng c
024 7 |a 10.1177/21925682251343523  |2 doi 
035 |a (DE-627)1935081136 
035 |a (DE-599)KXP1935081136 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Gierse, Jula  |d 1995-  |e VerfasserIn  |0 (DE-588)130882761X  |0 (DE-627)1869403142  |4 aut 
245 1 0 |a Analysis of screw/pedicle-width ratio and accuracy in navigated versus 3D-controlled fluoroscopy-guided pedicle screw placement  |c Jula Gierse MD, Felix Zimmermann MD, Paul A. Grützner, Jan Stallkamp, Sven Y. Vetter, and Eric Mandelka 
264 1 |c May 19, 2025 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 01.09.2025 
520 |a Study Design - Retrospective cohort study. - Objectives - Due to the close anatomic relationship between the pedicle and neurovascular structures, avoiding pedicle perforations is crucial in pedicle screw placement. Still, the use of larger screws has biomechanical advantages. Intraoperative 2D and 3D imaging, and navigation guidance can be used to combine both goals. The aim of this study was to compare the screw diameter/pedicle width ratio (SPR) and the screw placement accuracy for 3D controlled fluoroscopy-guided pedicle screw placement vs computer navigated transpedicular screw placement in the thoracic and lumbar spine. - Methods - 200 cases of thoracic and lumbar pedicle screw placement, of which 100 cases were performed using intraoperative computer navigation and 100 cases were performed using fluoroscopy-guidance were retrospectively registered. In the fluoroscopy group, intraoperative 3D scans were performed to confirm implant position and allow for potential intraoperative revision. In addition to accuracy and SPR, demographics, dose reports, and procedure times were analyzed. - Results - Overall, 716 fluoroscopy-guided screws were compared with 740 screws placed using navigation. Screw accuracy (83.2% vs 90.5%; P = .001) and SPR (0.85 ± 0.17 vs 0.88 ± 0.21; P < .001) were significantly higher using navigation compared to fluoroscopic guidance. Furthermore, dose area product (28,545 ± 17,693 vs 20,638 ± 15,856 mGycm2; P < .001), fluoroscopy time (223.6 ± 93.6 vs 92.3 ± 39.7 seconds; P < .001), and procedure time (154.0 ± 81.0 vs 119.7 ± 48.7 min; P = .004) were significantly lower using navigation. - Conclusions - Intraoperative navigation does not only increase the accuracy of pedicle screw placement, but also allows for the placement of larger screws relative to the pedicle width, which may have biomechanical advantages. Notably, contrary to other studies, the use of navigation did not increase patient radiation exposure or procedure time compared to fluoroscopic guidance. 
700 1 |a Zimmermann, Felix  |e VerfasserIn  |0 (DE-588)1312236620  |0 (DE-627)187203232X  |4 aut 
700 1 |a Grützner, Paul Alfred  |d 1962-  |e VerfasserIn  |0 (DE-588)111926688  |0 (DE-627)728553473  |0 (DE-576)372572863  |4 aut 
700 1 |a Stallkamp, Jan  |d 1967-  |e VerfasserIn  |0 (DE-588)1012904806  |0 (DE-627)704928558  |0 (DE-576)18960459X  |4 aut 
700 1 |a Vetter, Sven Y.  |d 1977-  |e VerfasserIn  |0 (DE-588)13390444X  |0 (DE-627)557959306  |0 (DE-576)300182740  |4 aut 
700 1 |a Mandelka, Leon Eric  |d 1993-  |e VerfasserIn  |0 (DE-588)1253523673  |0 (DE-627)1795729422  |4 aut 
773 0 8 |i Enthalten in  |t Global spine journal  |d Thousand Oaks, CA : Sage Publications, 2011  |g (2025), OnlineFirst, Artikel-ID 21925682251343523, Seite 1-9  |h Online-Ressource  |w (DE-627)684566346  |w (DE-600)2648287-3  |w (DE-576)402004337  |x 2192-5690  |7 nnas  |a Analysis of screw/pedicle-width ratio and accuracy in navigated versus 3D-controlled fluoroscopy-guided pedicle screw placement 
773 1 8 |g year:2025  |g number:OnlineFirst  |g elocationid:21925682251343523  |g pages:1-9  |g extent:9  |a Analysis of screw/pedicle-width ratio and accuracy in navigated versus 3D-controlled fluoroscopy-guided pedicle screw placement 
856 4 0 |u https://doi.org/10.1177/21925682251343523  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://journals.sagepub.com/doi/10.1177/21925682251343523  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20250901 
993 |a Article 
994 |a 2025 
998 |g 13390444X  |a Vetter, Sven Y.  |m 13390444X:Vetter, Sven Y.  |d 910000  |d 910200  |d 50000  |e 910000PV13390444X  |e 910200PV13390444X  |e 50000PV13390444X  |k 0/910000/  |k 1/910000/910200/  |k 0/50000/  |p 5 
998 |g 1012904806  |a Stallkamp, Jan  |m 1012904806:Stallkamp, Jan  |d 60000  |d 65200  |e 60000PS1012904806  |e 65200PS1012904806  |k 0/60000/  |k 1/60000/65200/  |p 4 
998 |g 111926688  |a Grützner, Paul Alfred  |m 111926688:Grützner, Paul Alfred  |d 50000  |e 50000PG111926688  |k 0/50000/  |p 3 
998 |g 1312236620  |a Zimmermann, Felix  |m 1312236620:Zimmermann, Felix  |d 50000  |e 50000PZ1312236620  |k 0/50000/  |p 2 
999 |a KXP-PPN1935081136  |e 4766546679 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"given":"Jula","display":"Gierse, Jula","role":"aut","family":"Gierse"},{"given":"Felix","family":"Zimmermann","display":"Zimmermann, Felix","role":"aut"},{"given":"Paul Alfred","display":"Grützner, Paul Alfred","role":"aut","family":"Grützner"},{"display":"Stallkamp, Jan","role":"aut","family":"Stallkamp","given":"Jan"},{"role":"aut","display":"Vetter, Sven Y.","family":"Vetter","given":"Sven Y."},{"given":"Leon Eric","display":"Mandelka, Leon Eric","role":"aut","family":"Mandelka"}],"id":{"eki":["1935081136"],"doi":["10.1177/21925682251343523"]},"origin":[{"dateIssuedKey":"2025","dateIssuedDisp":"May 19, 2025"}],"name":{"displayForm":["Jula Gierse MD, Felix Zimmermann MD, Paul A. Grützner, Jan Stallkamp, Sven Y. Vetter, and Eric Mandelka"]},"title":[{"title_sort":"Analysis of screw/pedicle-width ratio and accuracy in navigated versus 3D-controlled fluoroscopy-guided pedicle screw placement","title":"Analysis of screw/pedicle-width ratio and accuracy in navigated versus 3D-controlled fluoroscopy-guided pedicle screw placement"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"relHost":[{"language":["eng"],"pubHistory":["1.2011,Dez. -"],"part":{"year":"2025","text":"(2025), OnlineFirst, Artikel-ID 21925682251343523, Seite 1-9","issue":"OnlineFirst","extent":"9","pages":"1-9"},"id":{"zdb":["2648287-3"],"doi":["10.1055/s-00000177"],"eki":["684566346"],"issn":["2192-5690"]},"origin":[{"publisher":"Sage Publications ; Thieme","dateIssuedKey":"2011","publisherPlace":"Thousand Oaks, CA ; Stuttgart","dateIssuedDisp":"2011-"}],"disp":"Analysis of screw/pedicle-width ratio and accuracy in navigated versus 3D-controlled fluoroscopy-guided pedicle screw placementGlobal spine journal","title":[{"title_sort":"Global spine journal","title":"Global spine journal"}],"physDesc":[{"extent":"Online-Ressource"}],"recId":"684566346","note":["Fortsetzung der Druck-Ausgabe","Gesehen am 16.07.19"],"type":{"bibl":"periodical","media":"Online-Ressource"}}],"recId":"1935081136","physDesc":[{"extent":"9 S."}],"language":["eng"],"note":["Gesehen am 01.09.2025"]} 
SRT |a GIERSEJULAANALYSISOF1920