Analysis of screw/pedicle-width ratio and accuracy in navigated versus 3D-controlled fluoroscopy-guided pedicle screw placement
Study Design - Retrospective cohort study. - Objectives - Due to the close anatomic relationship between the pedicle and neurovascular structures, avoiding pedicle perforations is crucial in pedicle screw placement. Still, the use of larger screws has biomechanical advantages. Intraoperative 2D and...
Gespeichert in:
| Hauptverfasser: | , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
May 19, 2025
|
| In: |
Global spine journal
Year: 2025, Heft: OnlineFirst, Pages: 1-9 |
| ISSN: | 2192-5690 |
| DOI: | 10.1177/21925682251343523 |
| Online-Zugang: | Verlag, kostenfrei, Volltext: https://doi.org/10.1177/21925682251343523 Verlag, kostenfrei, Volltext: https://journals.sagepub.com/doi/10.1177/21925682251343523 |
| Verfasserangaben: | Jula Gierse MD, Felix Zimmermann MD, Paul A. Grützner, Jan Stallkamp, Sven Y. Vetter, and Eric Mandelka |
MARC
| LEADER | 00000caa a22000002c 4500 | ||
|---|---|---|---|
| 001 | 1935081136 | ||
| 003 | DE-627 | ||
| 005 | 20250902111843.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 250901s2025 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1177/21925682251343523 |2 doi | |
| 035 | |a (DE-627)1935081136 | ||
| 035 | |a (DE-599)KXP1935081136 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Gierse, Jula |d 1995- |e VerfasserIn |0 (DE-588)130882761X |0 (DE-627)1869403142 |4 aut | |
| 245 | 1 | 0 | |a Analysis of screw/pedicle-width ratio and accuracy in navigated versus 3D-controlled fluoroscopy-guided pedicle screw placement |c Jula Gierse MD, Felix Zimmermann MD, Paul A. Grützner, Jan Stallkamp, Sven Y. Vetter, and Eric Mandelka |
| 264 | 1 | |c May 19, 2025 | |
| 300 | |a 9 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 01.09.2025 | ||
| 520 | |a Study Design - Retrospective cohort study. - Objectives - Due to the close anatomic relationship between the pedicle and neurovascular structures, avoiding pedicle perforations is crucial in pedicle screw placement. Still, the use of larger screws has biomechanical advantages. Intraoperative 2D and 3D imaging, and navigation guidance can be used to combine both goals. The aim of this study was to compare the screw diameter/pedicle width ratio (SPR) and the screw placement accuracy for 3D controlled fluoroscopy-guided pedicle screw placement vs computer navigated transpedicular screw placement in the thoracic and lumbar spine. - Methods - 200 cases of thoracic and lumbar pedicle screw placement, of which 100 cases were performed using intraoperative computer navigation and 100 cases were performed using fluoroscopy-guidance were retrospectively registered. In the fluoroscopy group, intraoperative 3D scans were performed to confirm implant position and allow for potential intraoperative revision. In addition to accuracy and SPR, demographics, dose reports, and procedure times were analyzed. - Results - Overall, 716 fluoroscopy-guided screws were compared with 740 screws placed using navigation. Screw accuracy (83.2% vs 90.5%; P = .001) and SPR (0.85 ± 0.17 vs 0.88 ± 0.21; P < .001) were significantly higher using navigation compared to fluoroscopic guidance. Furthermore, dose area product (28,545 ± 17,693 vs 20,638 ± 15,856 mGycm2; P < .001), fluoroscopy time (223.6 ± 93.6 vs 92.3 ± 39.7 seconds; P < .001), and procedure time (154.0 ± 81.0 vs 119.7 ± 48.7 min; P = .004) were significantly lower using navigation. - Conclusions - Intraoperative navigation does not only increase the accuracy of pedicle screw placement, but also allows for the placement of larger screws relative to the pedicle width, which may have biomechanical advantages. Notably, contrary to other studies, the use of navigation did not increase patient radiation exposure or procedure time compared to fluoroscopic guidance. | ||
| 700 | 1 | |a Zimmermann, Felix |e VerfasserIn |0 (DE-588)1312236620 |0 (DE-627)187203232X |4 aut | |
| 700 | 1 | |a Grützner, Paul Alfred |d 1962- |e VerfasserIn |0 (DE-588)111926688 |0 (DE-627)728553473 |0 (DE-576)372572863 |4 aut | |
| 700 | 1 | |a Stallkamp, Jan |d 1967- |e VerfasserIn |0 (DE-588)1012904806 |0 (DE-627)704928558 |0 (DE-576)18960459X |4 aut | |
| 700 | 1 | |a Vetter, Sven Y. |d 1977- |e VerfasserIn |0 (DE-588)13390444X |0 (DE-627)557959306 |0 (DE-576)300182740 |4 aut | |
| 700 | 1 | |a Mandelka, Leon Eric |d 1993- |e VerfasserIn |0 (DE-588)1253523673 |0 (DE-627)1795729422 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Global spine journal |d Thousand Oaks, CA : Sage Publications, 2011 |g (2025), OnlineFirst, Artikel-ID 21925682251343523, Seite 1-9 |h Online-Ressource |w (DE-627)684566346 |w (DE-600)2648287-3 |w (DE-576)402004337 |x 2192-5690 |7 nnas |a Analysis of screw/pedicle-width ratio and accuracy in navigated versus 3D-controlled fluoroscopy-guided pedicle screw placement |
| 773 | 1 | 8 | |g year:2025 |g number:OnlineFirst |g elocationid:21925682251343523 |g pages:1-9 |g extent:9 |a Analysis of screw/pedicle-width ratio and accuracy in navigated versus 3D-controlled fluoroscopy-guided pedicle screw placement |
| 856 | 4 | 0 | |u https://doi.org/10.1177/21925682251343523 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://journals.sagepub.com/doi/10.1177/21925682251343523 |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20250901 | ||
| 993 | |a Article | ||
| 994 | |a 2025 | ||
| 998 | |g 13390444X |a Vetter, Sven Y. |m 13390444X:Vetter, Sven Y. |d 910000 |d 910200 |d 50000 |e 910000PV13390444X |e 910200PV13390444X |e 50000PV13390444X |k 0/910000/ |k 1/910000/910200/ |k 0/50000/ |p 5 | ||
| 998 | |g 1012904806 |a Stallkamp, Jan |m 1012904806:Stallkamp, Jan |d 60000 |d 65200 |e 60000PS1012904806 |e 65200PS1012904806 |k 0/60000/ |k 1/60000/65200/ |p 4 | ||
| 998 | |g 111926688 |a Grützner, Paul Alfred |m 111926688:Grützner, Paul Alfred |d 50000 |e 50000PG111926688 |k 0/50000/ |p 3 | ||
| 998 | |g 1312236620 |a Zimmermann, Felix |m 1312236620:Zimmermann, Felix |d 50000 |e 50000PZ1312236620 |k 0/50000/ |p 2 | ||
| 999 | |a KXP-PPN1935081136 |e 4766546679 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"person":[{"given":"Jula","display":"Gierse, Jula","role":"aut","family":"Gierse"},{"given":"Felix","family":"Zimmermann","display":"Zimmermann, Felix","role":"aut"},{"given":"Paul Alfred","display":"Grützner, Paul Alfred","role":"aut","family":"Grützner"},{"display":"Stallkamp, Jan","role":"aut","family":"Stallkamp","given":"Jan"},{"role":"aut","display":"Vetter, Sven Y.","family":"Vetter","given":"Sven Y."},{"given":"Leon Eric","display":"Mandelka, Leon Eric","role":"aut","family":"Mandelka"}],"id":{"eki":["1935081136"],"doi":["10.1177/21925682251343523"]},"origin":[{"dateIssuedKey":"2025","dateIssuedDisp":"May 19, 2025"}],"name":{"displayForm":["Jula Gierse MD, Felix Zimmermann MD, Paul A. Grützner, Jan Stallkamp, Sven Y. Vetter, and Eric Mandelka"]},"title":[{"title_sort":"Analysis of screw/pedicle-width ratio and accuracy in navigated versus 3D-controlled fluoroscopy-guided pedicle screw placement","title":"Analysis of screw/pedicle-width ratio and accuracy in navigated versus 3D-controlled fluoroscopy-guided pedicle screw placement"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"relHost":[{"language":["eng"],"pubHistory":["1.2011,Dez. -"],"part":{"year":"2025","text":"(2025), OnlineFirst, Artikel-ID 21925682251343523, Seite 1-9","issue":"OnlineFirst","extent":"9","pages":"1-9"},"id":{"zdb":["2648287-3"],"doi":["10.1055/s-00000177"],"eki":["684566346"],"issn":["2192-5690"]},"origin":[{"publisher":"Sage Publications ; Thieme","dateIssuedKey":"2011","publisherPlace":"Thousand Oaks, CA ; Stuttgart","dateIssuedDisp":"2011-"}],"disp":"Analysis of screw/pedicle-width ratio and accuracy in navigated versus 3D-controlled fluoroscopy-guided pedicle screw placementGlobal spine journal","title":[{"title_sort":"Global spine journal","title":"Global spine journal"}],"physDesc":[{"extent":"Online-Ressource"}],"recId":"684566346","note":["Fortsetzung der Druck-Ausgabe","Gesehen am 16.07.19"],"type":{"bibl":"periodical","media":"Online-Ressource"}}],"recId":"1935081136","physDesc":[{"extent":"9 S."}],"language":["eng"],"note":["Gesehen am 01.09.2025"]} | ||
| SRT | |a GIERSEJULAANALYSISOF1920 | ||