Continuous measurement of porcine renal cortex microcirculation with enhanced thermal diffusion technology

Continuous monitoring of renal cortical blood flow (RCBF) in the perioperative setting of aortic or renal vascular surgery could faciliate the early detection of vascular complications, possibly resulting in a reduction of postoperative renal failure. A new prototype system for measurement of parenc...

Full description

Saved in:
Bibliographic Details
Main Authors: Kraus, Thomas W. (Author) , Klar, Ernst (Author) , Osswald, Brigitte (Author) , Pinto Fernandes, Luiz (Author) , Mehrabi, Arianeb (Author) , Gebhard, Martha-Maria (Author) , Herfarth, Christian (Author)
Format: Article (Journal)
Language:English
Published: March 1996
In: Journal of surgical research
Year: 1996, Volume: 61, Issue: 2, Pages: 531-536
ISSN:1095-8673
DOI:10.1006/jsre.1996.0159
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1006/jsre.1996.0159
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0022480496901596
Get full text
Author Notes:T. Kraus, E. Klar, B.R. Osswald, L. Fernandes, A. Mehrabi, M.M. Gebhard, and C. Herfarth

MARC

LEADER 00000naa a2200000 c 4500
001 1935240854
003 DE-627
005 20250903125706.0
007 cr uuu---uuuuu
008 250903s1996 xx |||||o 00| ||eng c
024 7 |a 10.1006/jsre.1996.0159  |2 doi 
035 |a (DE-627)1935240854 
035 |a (DE-599)KXP1935240854 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Kraus, Thomas W.  |d 196X-  |e VerfasserIn  |0 (DE-588)1079822542  |0 (DE-627)842183981  |0 (DE-576)184973236  |4 aut 
245 1 0 |a Continuous measurement of porcine renal cortex microcirculation with enhanced thermal diffusion technology  |c T. Kraus, E. Klar, B.R. Osswald, L. Fernandes, A. Mehrabi, M.M. Gebhard, and C. Herfarth 
264 1 |c March 1996 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Elektronische Reproduktion der Druck-Ausgabe 25. Mai 2002 
500 |a Gesehen am 03.09.2025 
520 |a Continuous monitoring of renal cortical blood flow (RCBF) in the perioperative setting of aortic or renal vascular surgery could faciliate the early detection of vascular complications, possibly resulting in a reduction of postoperative renal failure. A new prototype system for measurement of parenchymous organ perfusion based on the principle of thermal diffusion (“TD”—Thermal Diffusion Electrode, Thermal Technologies Inc., Cambridge, MA, USA) was used for RCBF measurements in the outer cortex of the porcine kidney. We validated the sensitivity of the device to detect renal blood flow impairment, comparing TD flow data with renal artery blood flow values (RABF), measured by ultrasonic flow probes. The hypothesis was tested that acute disturbances of RCBF, induced by a variable degree of renal artery stenosis, can be immediately detected and continuously monitored by TD measurements in the porcine renal cortex. Mean baseline RCBF measured by TD electrodes was 68.1 ± 25.0 ml/100 g/min. Mean baseline RABF was 102.1 ± 26.6 ml/min. Controlled induction of a variable degree of renal arterial occlusion by implanted vascular balloon occluders was always followed by an immediate and proportional decline of RCBF, as measured by TD. Flow data obtained with both methods were significantly correlated by linear regression (r= .82,r2= .68;P< 0.0001). Dynamic changes of RABF in the time course of renal artery partial/total occlusion and arterial flow release could be continuously followed by detection of corresponding flow changes of RCBF. We conclude that the TD system investigated in the current study allows a continuous and sensitive determination of porcine renal cortex perfusion. A clinical evaluation of the method, e.g., in the perioperative setting of aortic or renal transplantation surgery, now appears to be justified. 
700 1 |a Klar, Ernst  |d 1952-  |e VerfasserIn  |0 (DE-588)136455107  |0 (DE-627)582906431  |0 (DE-576)301029326  |4 aut 
700 1 |a Osswald, Brigitte  |d 1964-  |e VerfasserIn  |0 (DE-588)1030334080  |0 (DE-627)735090114  |0 (DE-576)378135554  |4 aut 
700 1 |a Pinto Fernandes, Luiz  |e VerfasserIn  |0 (DE-588)1157409148  |0 (DE-627)1021240699  |0 (DE-576)502945001  |4 aut 
700 1 |a Mehrabi, Arianeb  |d 1967-  |e VerfasserIn  |0 (DE-588)137664583  |0 (DE-627)594829763  |0 (DE-576)304831263  |4 aut 
700 1 |a Gebhard, Martha-Maria  |d 1948-  |e VerfasserIn  |0 (DE-588)1076763278  |0 (DE-627)835312879  |0 (DE-576)445612789  |4 aut 
700 1 |a Herfarth, Christian  |d 1933-2014  |e VerfasserIn  |0 (DE-588)120706385  |0 (DE-627)080841562  |0 (DE-576)213333414  |4 aut 
773 0 8 |i Enthalten in  |t Journal of surgical research  |d Orlando, Fla. : Academic Press, 1961  |g 61(1996), 2, Artikel-ID 0159, Seite 531-536  |h Online-Ressource  |w (DE-627)267836821  |w (DE-600)1470806-1  |w (DE-576)104193948  |x 1095-8673  |7 nnas  |a Continuous measurement of porcine renal cortex microcirculation with enhanced thermal diffusion technology 
773 1 8 |g volume:61  |g year:1996  |g number:2  |g elocationid:0159  |g pages:531-536  |g extent:6  |a Continuous measurement of porcine renal cortex microcirculation with enhanced thermal diffusion technology 
856 4 0 |u https://doi.org/10.1006/jsre.1996.0159  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0022480496901596  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20250903 
993 |a Article 
994 |a 1996 
998 |g 120706385  |a Herfarth, Christian  |m 120706385:Herfarth, Christian  |d 910000  |d 910200  |e 910000PH120706385  |e 910200PH120706385  |k 0/910000/  |k 1/910000/910200/  |p 7  |y j 
998 |g 1076763278  |a Gebhard, Martha-Maria  |m 1076763278:Gebhard, Martha-Maria  |d 910000  |d 910200  |e 910000PG1076763278  |e 910200PG1076763278  |k 0/910000/  |k 1/910000/910200/  |p 6 
998 |g 137664583  |a Mehrabi, Arianeb  |m 137664583:Mehrabi, Arianeb  |d 910000  |d 910200  |e 910000PM137664583  |e 910200PM137664583  |k 0/910000/  |k 1/910000/910200/  |p 5 
998 |g 1030334080  |a Osswald, Brigitte  |m 1030334080:Osswald, Brigitte  |d 910000  |d 910200  |e 910000PO1030334080  |e 910200PO1030334080  |k 0/910000/  |k 1/910000/910200/  |p 3 
998 |g 136455107  |a Klar, Ernst  |m 136455107:Klar, Ernst  |d 910000  |d 910200  |e 910000PK136455107  |e 910200PK136455107  |k 0/910000/  |k 1/910000/910200/  |p 2 
998 |g 1079822542  |a Kraus, Thomas W.  |m 1079822542:Kraus, Thomas W.  |d 910000  |d 910200  |e 910000PK1079822542  |e 910200PK1079822542  |k 0/910000/  |k 1/910000/910200/  |p 1  |x j 
999 |a KXP-PPN1935240854  |e 4767239729 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedDisp":"March 1996","dateIssuedKey":"1996"}],"id":{"doi":["10.1006/jsre.1996.0159"],"eki":["1935240854"]},"recId":"1935240854","name":{"displayForm":["T. Kraus, E. Klar, B.R. Osswald, L. Fernandes, A. Mehrabi, M.M. Gebhard, and C. Herfarth"]},"title":[{"title_sort":"Continuous measurement of porcine renal cortex microcirculation with enhanced thermal diffusion technology","title":"Continuous measurement of porcine renal cortex microcirculation with enhanced thermal diffusion technology"}],"person":[{"display":"Kraus, Thomas W.","family":"Kraus","role":"aut","given":"Thomas W."},{"family":"Klar","role":"aut","given":"Ernst","display":"Klar, Ernst"},{"family":"Osswald","given":"Brigitte","role":"aut","display":"Osswald, Brigitte"},{"role":"aut","given":"Luiz","family":"Pinto Fernandes","display":"Pinto Fernandes, Luiz"},{"display":"Mehrabi, Arianeb","family":"Mehrabi","role":"aut","given":"Arianeb"},{"display":"Gebhard, Martha-Maria","family":"Gebhard","role":"aut","given":"Martha-Maria"},{"display":"Herfarth, Christian","given":"Christian","role":"aut","family":"Herfarth"}],"language":["eng"],"physDesc":[{"extent":"6 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"relHost":[{"disp":"Continuous measurement of porcine renal cortex microcirculation with enhanced thermal diffusion technologyJournal of surgical research","recId":"267836821","id":{"zdb":["1470806-1"],"issn":["1095-8673"],"eki":["267836821"]},"origin":[{"publisherPlace":"Orlando, Fla.","dateIssuedDisp":"1961-","dateIssuedKey":"1961","publisher":"Academic Press"}],"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"corporate":[{"role":"isb","display":"Association for Academic Surgery"},{"role":"isb","display":"Association of Veterans Administration Surgeons"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"title_sort":"Journal of surgical research","subtitle":"JSR ; clinical and laboratory investigation ; official publication of the Association for Academic Surgery ; official publication of the Association of Veterans Administration Surgeons","title":"Journal of surgical research"}],"part":{"issue":"2","year":"1996","text":"61(1996), 2, Artikel-ID 0159, Seite 531-536","extent":"6","volume":"61","pages":"531-536"},"pubHistory":["1.1961 -"],"titleAlt":[{"title":"JSR"}],"note":["Gesehen am 30.01.2020"]}],"note":["Elektronische Reproduktion der Druck-Ausgabe 25. Mai 2002","Gesehen am 03.09.2025"]} 
SRT |a KRAUSTHOMACONTINUOUS1996