A three-year experience with the balloon expandable GORE VIABAHN VBX in the treatment of thoraco-abdominal aortic aneurysms within the EXPAND trial
Objective - The EXPAND registry is a post-market, multicenter registry that aims at evaluating the safety and performance of the GORE VIABAHN VBX balloon expandable endoprosthesis (VBX stent) implanted in peripheral vessels. This subgroup analysis assesses the 3-year outcomes of the VBX stent as a b...
Gespeichert in:
| Hauptverfasser: | , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
[9 October 2024]
|
| In: |
Journal of vascular surgery
Year: 2025, Jahrgang: 81, Heft: 2, Pages: 319-323.e1 |
| ISSN: | 1097-6809 |
| DOI: | 10.1016/j.jvs.2024.10.002 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jvs.2024.10.002 Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0741521424019426 |
| Verfasserangaben: | Marco V. Usai, Mauro Gargiulo, Stéphan Haulon, Ignace Tielliu, Dittmar Böckler, Hence Verhagen, Alba Méndez Fernández, and Martin J. Austermann |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1936109743 | ||
| 003 | DE-627 | ||
| 005 | 20250930114509.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 250917s2024 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.jvs.2024.10.002 |2 doi | |
| 035 | |a (DE-627)1936109743 | ||
| 035 | |a (DE-599)KXP1936109743 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Usai, Marco Virgilio |e VerfasserIn |0 (DE-588)1222463172 |0 (DE-627)1741516455 |4 aut | |
| 245 | 1 | 2 | |a A three-year experience with the balloon expandable GORE VIABAHN VBX in the treatment of thoraco-abdominal aortic aneurysms within the EXPAND trial |c Marco V. Usai, Mauro Gargiulo, Stéphan Haulon, Ignace Tielliu, Dittmar Böckler, Hence Verhagen, Alba Méndez Fernández, and Martin J. Austermann |
| 264 | 1 | |c [9 October 2024] | |
| 300 | |b Diagramme | ||
| 300 | |a 6 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 17.09.2025 | ||
| 520 | |a Objective - The EXPAND registry is a post-market, multicenter registry that aims at evaluating the safety and performance of the GORE VIABAHN VBX balloon expandable endoprosthesis (VBX stent) implanted in peripheral vessels. This subgroup analysis assesses the 3-year outcomes of the VBX stent as a bridging stent graft for visceral vessels during branched endovascular aortic repair. - Methods - This prospective, multicenter, observational registry includes 16 European sites. Patients were enrolled from November 2018 to March 2022. Endpoints included 3-year primary patency (PP), secondary patency (SP), and stent graft-related death and serious adverse events. - Results - Seventy-three patients, of whom 57 (78.1%) were male, with a mean age of 73 years (±8.1 years) were included. At 3 years, 42 patients (57.5%) returned for follow-up. Overall, 223 target vessels (TVs) were treated. The estimated freedom from loss of TV PP was 93.6%. Per TV PP rates were 97.0% for the celiac trunk, 93.9% for the superior mesenteric artery, 91.2% for the left renal artery, and 92.5% for the right renal artery. The overall estimated freedom from loss of SP was 96.8%, and freedom from TV instability was 94.5%. - Conclusions - The VBX stent demonstrated excellent sustained results at 3 years with almost 94% PP, 97% SP, and 94.5% freedom from TV instability. Patency in the renal arteries was lower than in the celiac trunk and superior mesenteric artery. The VBX stent appears to be a reliable bridging stent for target vessels in branched endovascular aortic repair. | ||
| 650 | 4 | |a Balloon-expandable stent | |
| 650 | 4 | |a BEVAR | |
| 650 | 4 | |a Bridging stent graft | |
| 700 | 1 | |a Gargiulo, Mauro |e VerfasserIn |4 aut | |
| 700 | 1 | |a Haulon, Stéphan |e VerfasserIn |4 aut | |
| 700 | 1 | |a Tielliu, Ignace |e VerfasserIn |4 aut | |
| 700 | 1 | |a Böckler, Dittmar |d 1966- |e VerfasserIn |0 (DE-588)1032367881 |0 (DE-627)738382868 |0 (DE-576)173503969 |4 aut | |
| 700 | 1 | |a Verhagen, Hence |e VerfasserIn |4 aut | |
| 700 | 1 | |a Fernández, Alba Méndez |e VerfasserIn |4 aut | |
| 700 | 1 | |a Austermann, Martin Josef |d 1968- |e VerfasserIn |0 (DE-588)115726713 |0 (DE-627)691545138 |0 (DE-576)290042089 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of vascular surgery |d Amsterdam [u.a.] : Elsevier, 1984 |g 81(2025), 2, Seite 319-323.e1 |h Online-Ressource |w (DE-627)302720146 |w (DE-600)1492043-8 |w (DE-576)088704807 |x 1097-6809 |7 nnas |a A three-year experience with the balloon expandable GORE VIABAHN VBX in the treatment of thoraco-abdominal aortic aneurysms within the EXPAND trial |
| 773 | 1 | 8 | |g volume:81 |g year:2025 |g number:2 |g pages:319-323.e1 |g extent:6 |a A three-year experience with the balloon expandable GORE VIABAHN VBX in the treatment of thoraco-abdominal aortic aneurysms within the EXPAND trial |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.jvs.2024.10.002 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S0741521424019426 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20250917 | ||
| 993 | |a Article | ||
| 994 | |a 2024 | ||
| 998 | |g 1032367881 |a Böckler, Dittmar |m 1032367881:Böckler, Dittmar |d 910000 |d 910200 |e 910000PB1032367881 |e 910200PB1032367881 |k 0/910000/ |k 1/910000/910200/ |p 5 | ||
| 999 | |a KXP-PPN1936109743 |e 4772868224 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"note":["Gesehen am 17.09.2025"],"recId":"1936109743","person":[{"display":"Usai, Marco Virgilio","given":"Marco Virgilio","family":"Usai","role":"aut"},{"role":"aut","family":"Gargiulo","given":"Mauro","display":"Gargiulo, Mauro"},{"role":"aut","family":"Haulon","display":"Haulon, Stéphan","given":"Stéphan"},{"display":"Tielliu, Ignace","given":"Ignace","role":"aut","family":"Tielliu"},{"display":"Böckler, Dittmar","given":"Dittmar","role":"aut","family":"Böckler"},{"role":"aut","family":"Verhagen","display":"Verhagen, Hence","given":"Hence"},{"given":"Alba Méndez","display":"Fernández, Alba Méndez","family":"Fernández","role":"aut"},{"given":"Martin Josef","display":"Austermann, Martin Josef","family":"Austermann","role":"aut"}],"language":["eng"],"name":{"displayForm":["Marco V. Usai, Mauro Gargiulo, Stéphan Haulon, Ignace Tielliu, Dittmar Böckler, Hence Verhagen, Alba Méndez Fernández, and Martin J. Austermann"]},"origin":[{"dateIssuedKey":"2024","dateIssuedDisp":"[9 October 2024]"}],"relHost":[{"titleAlt":[{"title":"JVS"},{"title":"Vascular surgery"}],"disp":"A three-year experience with the balloon expandable GORE VIABAHN VBX in the treatment of thoraco-abdominal aortic aneurysms within the EXPAND trialJournal of vascular surgery","type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["1.1984 -"],"note":["Gesehen am 15.01.20"],"language":["eng"],"part":{"issue":"2","extent":"6","pages":"319-323.e1","text":"81(2025), 2, Seite 319-323.e1","year":"2025","volume":"81"},"origin":[{"publisher":"Elsevier ; Mosby","dateIssuedDisp":"1984-","dateIssuedKey":"1984","publisherPlace":"Amsterdam [u.a.] ; St. Louis, Mo."}],"title":[{"title":"Journal of vascular surgery","title_sort":"Journal of vascular surgery"}],"id":{"zdb":["1492043-8"],"eki":["302720146"],"issn":["1097-6809"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"302720146"}],"physDesc":[{"noteIll":"Diagramme","extent":"6 S."}],"id":{"doi":["10.1016/j.jvs.2024.10.002"],"eki":["1936109743"]},"title":[{"title_sort":"three-year experience with the balloon expandable GORE VIABAHN VBX in the treatment of thoraco-abdominal aortic aneurysms within the EXPAND trial","title":"A three-year experience with the balloon expandable GORE VIABAHN VBX in the treatment of thoraco-abdominal aortic aneurysms within the EXPAND trial"}],"type":{"media":"Online-Ressource","bibl":"article-journal"}} | ||
| SRT | |a USAIMARCOVTHREEYEARE9202 | ||