Comparison of ultrasound and MRI shows equivalent accuracy and reliability in acromial index measurement

The acromial index, a radiological parameter assessing the subacromial space, is vital for diagnosing conditions like rotator cuff tears and subacromial impingement syndrome as the acromial Index influences the choice of therapy. Traditionally determined via X-ray, AI is increasingly assessed using...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Schamberger, Christian T. (VerfasserIn) , Großner, Tobias (VerfasserIn) , Fischer, Christian (VerfasserIn) , Findeisen, Sebastian (VerfasserIn) , Ferbert, Thomas (VerfasserIn) , Böpple, Jessica C. (VerfasserIn) , Höppchen, Arnold (VerfasserIn) , Schmidmaier, Gerhard (VerfasserIn) , Stein, Stephan (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 3 July 2025
In: Scientific reports
Year: 2025, Jahrgang: 15, Pages: 1-10
ISSN:2045-2322
DOI:10.1038/s41598-025-07370-2
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1038/s41598-025-07370-2
Verlag, kostenfrei, Volltext: http://www.nature.com/articles/s41598-025-07370-2
Volltext
Verfasserangaben:Christian T. Schamberger, Tobias Grossner, Christian Fischer, Sebastian Findeisen, Thomas Ferbert, Jessica C. Boepple, Arnold J. Höppchen, Gerhard Schmidmaier & Stephan Stein

MARC

LEADER 00000caa a2200000 c 4500
001 193616969X
003 DE-627
005 20250930114509.0
007 cr uuu---uuuuu
008 250918s2025 xx |||||o 00| ||eng c
024 7 |a 10.1038/s41598-025-07370-2  |2 doi 
035 |a (DE-627)193616969X 
035 |a (DE-599)KXP193616969X 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schamberger, Christian T.  |d 1975-  |e VerfasserIn  |0 (DE-588)1166904725  |0 (DE-627)1030775419  |0 (DE-576)510960146  |4 aut 
245 1 0 |a Comparison of ultrasound and MRI shows equivalent accuracy and reliability in acromial index measurement  |c Christian T. Schamberger, Tobias Grossner, Christian Fischer, Sebastian Findeisen, Thomas Ferbert, Jessica C. Boepple, Arnold J. Höppchen, Gerhard Schmidmaier & Stephan Stein 
264 1 |c 3 July 2025 
300 |b Illustrationen, Diagramme 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 16.09.2025 
520 |a The acromial index, a radiological parameter assessing the subacromial space, is vital for diagnosing conditions like rotator cuff tears and subacromial impingement syndrome as the acromial Index influences the choice of therapy. Traditionally determined via X-ray, AI is increasingly assessed using MRI due to its superior image quality. However, MRI’s cost and limited availability highlight the need for alternative methods. Ultrasound offers a promising, cost-effective alternative, providing real-time imaging without radiation exposure. This study aims to compare the accuracy and reliability of ultrasound-based AI determination with MRI. This retrospective study enrolled patients with shoulder complaints who underwent both MRI and ultrasound examinations between November 2021 and October 2022. Inclusion criteria included appropriate MRI and ultrasound images of the shoulder joint. AI was measured on MRI images and a modified AI was assessed using ultrasound. Statistical analyses evaluated the accuracy and reliability of both methods, focusing on intra- and interobserver consistency. A total of 113 patients (53.2 years average age, 31.3% female) were included. The mean MRI-determined AI was 0.65 (SD 0.065), with 15.6% showing pathological AI. Ultrasound-determined modified acromial index averaged 0.74 (SD 0.122), with 33% showing pathological modified acromial index. Comparative analysis showed no significant difference between MRI and ultrasound measurements (p = 0.237). Both methods demonstrated high intra- and interobserver reliability (ICC values > 0.9). Ultrasound-assisted AI determination is a valid, reproducible, and reliable alternative to MRI. Its advantages include cost-effectiveness, accessibility, and absence of ionizing radiation, making it particularly useful in resource-limited settings. 
650 4 |a Clinical trial design 
650 4 |a Diseases 
700 1 |a Großner, Tobias  |d 1980-  |e VerfasserIn  |0 (DE-588)1082560391  |0 (DE-627)847639401  |0 (DE-576)45550928X  |4 aut 
700 1 |a Fischer, Christian  |d 1979-  |e VerfasserIn  |0 (DE-588)1167802500  |0 (DE-627)1031300945  |0 (DE-576)511278608  |4 aut 
700 1 |a Findeisen, Sebastian  |e VerfasserIn  |0 (DE-588)1129634353  |0 (DE-627)884273695  |0 (DE-576)486475999  |4 aut 
700 1 |a Ferbert, Thomas  |d 1983-  |e VerfasserIn  |0 (DE-588)1028065248  |0 (DE-627)73025951X  |0 (DE-576)375553371  |4 aut 
700 1 |a Böpple, Jessica C.  |d 1998-  |e VerfasserIn  |0 (DE-588)1265424403  |0 (DE-627)1814326391  |4 aut 
700 1 |a Höppchen, Arnold  |d 1978-  |e VerfasserIn  |0 (DE-588)1075748429  |0 (DE-627)833789589  |0 (DE-576)444622861  |4 aut 
700 1 |a Schmidmaier, Gerhard  |d 1970-  |e VerfasserIn  |0 (DE-588)121147207  |0 (DE-627)394702662  |0 (DE-576)292558600  |4 aut 
700 1 |a Stein, Stephan  |d 1994-  |e VerfasserIn  |0 (DE-588)133162391X  |0 (DE-627)1890621919  |4 aut 
773 0 8 |i Enthalten in  |t Scientific reports  |d [London] : Springer Nature, 2011  |g 15(2025), Artikel-ID 23824, Seite 1-10  |h Online-Ressource  |w (DE-627)663366712  |w (DE-600)2615211-3  |w (DE-576)346641179  |x 2045-2322  |7 nnas  |a Comparison of ultrasound and MRI shows equivalent accuracy and reliability in acromial index measurement 
773 1 8 |g volume:15  |g year:2025  |g elocationid:23824  |g pages:1-10  |g extent:10  |a Comparison of ultrasound and MRI shows equivalent accuracy and reliability in acromial index measurement 
856 4 0 |u https://doi.org/10.1038/s41598-025-07370-2  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u http://www.nature.com/articles/s41598-025-07370-2  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20250918 
993 |a Article 
994 |a 2025 
998 |g 133162391X  |a Stein, Stephan  |m 133162391X:Stein, Stephan  |d 910000  |d 911460  |e 910000PS133162391X  |e 911460PS133162391X  |k 0/910000/  |k 1/910000/911460/  |p 9  |y j 
998 |g 121147207  |a Schmidmaier, Gerhard  |m 121147207:Schmidmaier, Gerhard  |d 910000  |d 911460  |e 910000PS121147207  |e 911460PS121147207  |k 0/910000/  |k 1/910000/911460/  |p 8 
998 |g 1075748429  |a Höppchen, Arnold  |m 1075748429:Höppchen, Arnold  |d 60000  |d 62400  |e 60000PH1075748429  |e 62400PH1075748429  |k 0/60000/  |k 1/60000/62400/  |p 7 
998 |g 1265424403  |a Böpple, Jessica C.  |m 1265424403:Böpple, Jessica C.  |d 60000  |d 62400  |e 60000PB1265424403  |e 62400PB1265424403  |k 0/60000/  |k 1/60000/62400/  |p 6 
998 |g 1028065248  |a Ferbert, Thomas  |m 1028065248:Ferbert, Thomas  |d 910000  |d 911460  |e 910000PF1028065248  |e 911460PF1028065248  |k 0/910000/  |k 1/910000/911460/  |p 5 
998 |g 1129634353  |a Findeisen, Sebastian  |m 1129634353:Findeisen, Sebastian  |d 910000  |d 911460  |e 910000PF1129634353  |e 911460PF1129634353  |k 0/910000/  |k 1/910000/911460/  |p 4 
998 |g 1167802500  |a Fischer, Christian  |m 1167802500:Fischer, Christian  |d 50000  |e 50000PF1167802500  |k 0/50000/  |p 3 
998 |g 1082560391  |a Großner, Tobias  |m 1082560391:Großner, Tobias  |d 910000  |d 911460  |e 910000PG1082560391  |e 911460PG1082560391  |k 0/910000/  |k 1/910000/911460/  |p 2 
998 |g 1166904725  |a Schamberger, Christian T.  |m 1166904725:Schamberger, Christian T.  |d 910000  |d 911460  |e 910000PS1166904725  |e 911460PS1166904725  |k 0/910000/  |k 1/910000/911460/  |p 1  |x j 
999 |a KXP-PPN193616969X  |e 4773261544 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"193616969X","relHost":[{"disp":"Comparison of ultrasound and MRI shows equivalent accuracy and reliability in acromial index measurementScientific reports","physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Scientific reports","title":"Scientific reports"}],"part":{"extent":"10","volume":"15","pages":"1-10","year":"2025","text":"15(2025), Artikel-ID 23824, Seite 1-10"},"type":{"media":"Online-Ressource","bibl":"periodical"},"id":{"zdb":["2615211-3"],"eki":["663366712"],"issn":["2045-2322"]},"language":["eng"],"recId":"663366712","pubHistory":["1, article number 1 (2011)-"],"note":["Gesehen am 12.07.24"],"origin":[{"publisherPlace":"[London] ; London","dateIssuedKey":"2011","dateIssuedDisp":"2011-","publisher":"Springer Nature ; Nature Publishing Group"}]}],"note":["Gesehen am 16.09.2025"],"origin":[{"dateIssuedKey":"2025","dateIssuedDisp":"3 July 2025"}],"title":[{"title":"Comparison of ultrasound and MRI shows equivalent accuracy and reliability in acromial index measurement","title_sort":"Comparison of ultrasound and MRI shows equivalent accuracy and reliability in acromial index measurement"}],"person":[{"family":"Schamberger","given":"Christian T.","display":"Schamberger, Christian T.","role":"aut"},{"family":"Großner","role":"aut","given":"Tobias","display":"Großner, Tobias"},{"family":"Fischer","role":"aut","given":"Christian","display":"Fischer, Christian"},{"family":"Findeisen","role":"aut","display":"Findeisen, Sebastian","given":"Sebastian"},{"given":"Thomas","display":"Ferbert, Thomas","role":"aut","family":"Ferbert"},{"family":"Böpple","display":"Böpple, Jessica C.","given":"Jessica C.","role":"aut"},{"family":"Höppchen","given":"Arnold","display":"Höppchen, Arnold","role":"aut"},{"family":"Schmidmaier","role":"aut","given":"Gerhard","display":"Schmidmaier, Gerhard"},{"role":"aut","given":"Stephan","display":"Stein, Stephan","family":"Stein"}],"id":{"eki":["193616969X"],"doi":["10.1038/s41598-025-07370-2"]},"physDesc":[{"noteIll":"Illustrationen, Diagramme","extent":"10 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"name":{"displayForm":["Christian T. Schamberger, Tobias Grossner, Christian Fischer, Sebastian Findeisen, Thomas Ferbert, Jessica C. Boepple, Arnold J. Höppchen, Gerhard Schmidmaier & Stephan Stein"]}} 
SRT |a SCHAMBERGECOMPARISON3202