Reduction of streak artifacts in the superior vena cava for better visualization of mediastinal structures through virtual monoenergetic reconstructions using a photon-counting detector computed tomography
Purpose: - Computed tomography (CT) is crucial in oncologic imaging for precise diagnosis and staging. Beam-hardening artifacts from contrast media in the superior vena cava can degrade image quality and obscure adjacent structures, complicating lymph node assessment. This study examines...
Gespeichert in:
| Hauptverfasser: | , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
July 2025
|
| In: |
Journal of thoracic imaging
Year: 2025, Jahrgang: 40, Heft: 4, Pages: ? |
| ISSN: | 1536-0237 |
| DOI: | 10.1097/RTI.0000000000000822 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1097/RTI.0000000000000822 Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/thoracicimaging/abstract/2025/07000/reduction_of_streak_artifacts_in_the_superior_vena.3.aspx |
| Verfasserangaben: | Thater, Greta MD, Frerichs, Isabel, Büttner, Sylvia, Schoenberg, Stefan O. MD, Froelich, Matthias MD, Ayx, Isabelle MD |
MARC
| LEADER | 00000caa a22000002c 4500 | ||
|---|---|---|---|
| 001 | 1936358786 | ||
| 003 | DE-627 | ||
| 005 | 20250930114509.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 250922s2025 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1097/RTI.0000000000000822 |2 doi | |
| 035 | |a (DE-627)1936358786 | ||
| 035 | |a (DE-599)KXP1936358786 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Thater, Greta |d 1991- |e VerfasserIn |0 (DE-588)1227899998 |0 (DE-627)1749105675 |4 aut | |
| 245 | 1 | 0 | |a Reduction of streak artifacts in the superior vena cava for better visualization of mediastinal structures through virtual monoenergetic reconstructions using a photon-counting detector computed tomography |c Thater, Greta MD, Frerichs, Isabel, Büttner, Sylvia, Schoenberg, Stefan O. MD, Froelich, Matthias MD, Ayx, Isabelle MD |
| 264 | 1 | |c July 2025 | |
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 22.09.2025 | ||
| 520 | |a Purpose: - Computed tomography (CT) is crucial in oncologic imaging for precise diagnosis and staging. Beam-hardening artifacts from contrast media in the superior vena cava can degrade image quality and obscure adjacent structures, complicating lymph node assessment. This study examines the use of virtual monoenergetic reconstruction with photon-counting detector CT (photon-counting CT) to mitigate these artifacts. - Materials and Methods: - The retrospective study included 50 patients who underwent thoracoabdominal scans. Virtual monoenergetic reconstructions at nine keV levels (60 to 140 keV) were analyzed for Hounsfield Unit (HU) stability, image noise, and artifact index in various regions of interest (ROIs): mediastinal adipose tissue (ROI 1 to 3) and vascular stations (ROI 4 to 6) were compared with reference tissue (ROI 7 to 8). The diagnostic image quality of the keV levels was assessed using a 5-point Likert Scale. - Results: - Lower keV values (60 to 80) exhibited higher image noise and lower HU stability in mediastinal adipose tissue compared with higher energies, with optimal noise reduction observed at 130 keV (ROI 1 to 3). HU stability in vascular structures (ROI 4 to 6) significantly improved above 80 keV, with the best performance at 140 keV. Artifact levels decreased progressively from 60 to 140 keV. Visually, keV levels of 110 keV (96% Likert ≥4) and 120 keV (60% Likert 4) were rated most diagnostically valuable, consistent with technical findings. - Conclusion: - Virtual monoenergetic reconstructions with photon-counting CT effectively reduce beam-hardening artifacts near the superior vena cava, enhancing the visualization of lymph nodes and adjacent structures. This technology advances oncologic imaging by improving diagnostic accuracy in areas previously affected by artifact-related image degradation. | ||
| 700 | 1 | |a Frerichs, Isabel |d 1999- |e VerfasserIn |0 (DE-588)1377116603 |0 (DE-627)1936360470 |4 aut | |
| 700 | 1 | |a Büttner, Sylvia |d 1962- |e VerfasserIn |0 (DE-588)1038291364 |0 (DE-627)75693611X |0 (DE-576)392282550 |4 aut | |
| 700 | 1 | |a Schönberg, Stefan |d 1969- |e VerfasserIn |0 (DE-588)131557912 |0 (DE-627)510700624 |0 (DE-576)298584891 |4 aut | |
| 700 | 1 | |a Froelich, Matthias F. |d 1991- |e VerfasserIn |0 (DE-588)1170833756 |0 (DE-627)1040131557 |0 (DE-576)512678359 |4 aut | |
| 700 | 1 | |a Ayx, Isabelle |d 1988- |e VerfasserIn |0 (DE-588)1052154514 |0 (DE-627)787934178 |0 (DE-576)407912959 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of thoracic imaging |d Philadelphia, Pa. : Lippincott Williams & Wilkins, 1985 |g 40(2025), 4 vom: Juli, Artikel-ID e0822, Seite ? |h Online-Ressource |w (DE-627)330078178 |w (DE-600)2048799-X |w (DE-576)263808351 |x 1536-0237 |7 nnas |a Reduction of streak artifacts in the superior vena cava for better visualization of mediastinal structures through virtual monoenergetic reconstructions using a photon-counting detector computed tomography |
| 773 | 1 | 8 | |g volume:40 |g year:2025 |g number:4 |g month:07 |g elocationid:e0822 |g pages:? |a Reduction of streak artifacts in the superior vena cava for better visualization of mediastinal structures through virtual monoenergetic reconstructions using a photon-counting detector computed tomography |
| 856 | 4 | 0 | |u https://doi.org/10.1097/RTI.0000000000000822 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://journals.lww.com/thoracicimaging/abstract/2025/07000/reduction_of_streak_artifacts_in_the_superior_vena.3.aspx |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20250922 | ||
| 993 | |a Article | ||
| 994 | |a 2025 | ||
| 998 | |g 1052154514 |a Ayx, Isabelle |m 1052154514:Ayx, Isabelle |d 60000 |d 62900 |d 60000 |e 60000PA1052154514 |e 62900PA1052154514 |e 60000PA1052154514 |k 0/60000/ |k 1/60000/62900/ |k 0/60000/ |p 6 |y j | ||
| 998 | |g 1170833756 |a Froelich, Matthias F. |m 1170833756:Froelich, Matthias F. |d 60000 |d 62900 |d 60000 |e 60000PF1170833756 |e 62900PF1170833756 |e 60000PF1170833756 |k 0/60000/ |k 1/60000/62900/ |k 0/60000/ |p 5 | ||
| 998 | |g 131557912 |a Schönberg, Stefan |m 131557912:Schönberg, Stefan |d 60000 |d 62900 |e 60000PS131557912 |e 62900PS131557912 |k 0/60000/ |k 1/60000/62900/ |p 4 | ||
| 998 | |g 1038291364 |a Büttner, Sylvia |m 1038291364:Büttner, Sylvia |d 60000 |d 60200 |d 60250 |e 60000PB1038291364 |e 60200PB1038291364 |e 60250PB1038291364 |k 0/60000/ |k 1/60000/60200/ |k 2/60000/60200/60250/ |p 3 | ||
| 998 | |g 1377116603 |a Frerichs, Isabel |m 1377116603:Frerichs, Isabel |d 60000 |e 60000PF1377116603 |k 0/60000/ |p 2 | ||
| 998 | |g 1227899998 |a Thater, Greta |m 1227899998:Thater, Greta |d 60000 |e 60000PT1227899998 |k 0/60000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1936358786 |e 4774768006 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"name":{"displayForm":["Thater, Greta MD, Frerichs, Isabel, Büttner, Sylvia, Schoenberg, Stefan O. MD, Froelich, Matthias MD, Ayx, Isabelle MD"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"recId":"1936358786","id":{"doi":["10.1097/RTI.0000000000000822"],"eki":["1936358786"]},"note":["Gesehen am 22.09.2025"],"origin":[{"dateIssuedKey":"2025","dateIssuedDisp":"July 2025"}],"title":[{"title_sort":"Reduction of streak artifacts in the superior vena cava for better visualization of mediastinal structures through virtual monoenergetic reconstructions using a photon-counting detector computed tomography","title":"Reduction of streak artifacts in the superior vena cava for better visualization of mediastinal structures through virtual monoenergetic reconstructions using a photon-counting detector computed tomography"}],"person":[{"given":"Greta","family":"Thater","role":"aut","display":"Thater, Greta"},{"family":"Frerichs","given":"Isabel","role":"aut","display":"Frerichs, Isabel"},{"display":"Büttner, Sylvia","role":"aut","family":"Büttner","given":"Sylvia"},{"role":"aut","display":"Schönberg, Stefan","family":"Schönberg","given":"Stefan"},{"display":"Froelich, Matthias F.","role":"aut","given":"Matthias F.","family":"Froelich"},{"given":"Isabelle","family":"Ayx","role":"aut","display":"Ayx, Isabelle"}],"relHost":[{"language":["eng"],"disp":"Reduction of streak artifacts in the superior vena cava for better visualization of mediastinal structures through virtual monoenergetic reconstructions using a photon-counting detector computed tomographyJournal of thoracic imaging","type":{"bibl":"periodical","media":"Online-Ressource"},"part":{"year":"2025","volume":"40","pages":"?","text":"40(2025), 4 vom: Juli, Artikel-ID e0822, Seite ?","issue":"4"},"title":[{"title_sort":"Journal of thoracic imaging","title":"Journal of thoracic imaging","subtitle":"official journal of the Society of Thoracic Radiology, Japanese Society of Thoracic Radiology and the Korean Society of Thoracic Radiology"}],"pubHistory":["1.1985 -"],"id":{"zdb":["2048799-X"],"eki":["330078178"],"issn":["1536-0237"]},"recId":"330078178","physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisherPlace":"Philadelphia, Pa. ; [Erscheinungsort nicht ermittelbar]","dateIssuedKey":"1985","publisher":"Lippincott Williams & Wilkins ; Ovid","dateIssuedDisp":"1985-"}],"note":["Gesehen am 04.02.25","Fortsetzung der Druck-Ausgabe"]}]} | ||
| SRT | |a THATERGRETREDUCTIONO2025 | ||